氯霉素在不同基质中的电化学传感研究进展

IF 3.7 Q1 CHEMISTRY, ANALYTICAL
Kgwadu Percy Mulaudji, Kefilwe Vanessa Mokwebo, Franklin Quelain De Bruin, Keagan Pokpas, Natasha Ross
{"title":"氯霉素在不同基质中的电化学传感研究进展","authors":"Kgwadu Percy Mulaudji,&nbsp;Kefilwe Vanessa Mokwebo,&nbsp;Franklin Quelain De Bruin,&nbsp;Keagan Pokpas,&nbsp;Natasha Ross","doi":"10.1016/j.talo.2025.100561","DOIUrl":null,"url":null,"abstract":"<div><div>Chloramphenicol (CAP) have demonstrated its broad effectiveness against bacterial infections. However, its persistence in the environment and potential toxicity led to strict global regulations limiting its use. As a result, rapid and accurate detection methods for CAP are being developed to protect public health and maintain regulatory compliance regarding its presence in the environment. Conventional analytical methods such as High-Performance Liquid Chromatography, Gas Chromatography, and Liquid Chromatography–Mass Spectrometry were commonly used for CAP detection. However, these conventional methods suffer challenges such as time-consumption, fabrication complexity, reproducibility, and cost. With electrochemical sensing techniques presenting varying valuable benefits, such as instant detection, low power consumption, simultaneous analysis, and portability, making them essential for timely monitoring of various analytes. The performance of electrochemical sensor is further boosted by integrating materials such as spinels, metal oxides, and metallic nanoparticles. These materials are broadly investigated as electrode interface components thanks to their features that collectively boost electrochemical sensor such as providing excellent electrical conductivity, distinct catalytic behavior, and larger surface areas. Furthermore, this paper reviews the impact of traditional and standards analytical methods, as well as their recent advancement based on the detection of CAP in aqueous media.</div></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":"12 ","pages":"Article 100561"},"PeriodicalIF":3.7000,"publicationDate":"2025-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advancement in electrochemical sensing of chloramphenicol in varying matrixes: A review\",\"authors\":\"Kgwadu Percy Mulaudji,&nbsp;Kefilwe Vanessa Mokwebo,&nbsp;Franklin Quelain De Bruin,&nbsp;Keagan Pokpas,&nbsp;Natasha Ross\",\"doi\":\"10.1016/j.talo.2025.100561\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Chloramphenicol (CAP) have demonstrated its broad effectiveness against bacterial infections. However, its persistence in the environment and potential toxicity led to strict global regulations limiting its use. As a result, rapid and accurate detection methods for CAP are being developed to protect public health and maintain regulatory compliance regarding its presence in the environment. Conventional analytical methods such as High-Performance Liquid Chromatography, Gas Chromatography, and Liquid Chromatography–Mass Spectrometry were commonly used for CAP detection. However, these conventional methods suffer challenges such as time-consumption, fabrication complexity, reproducibility, and cost. With electrochemical sensing techniques presenting varying valuable benefits, such as instant detection, low power consumption, simultaneous analysis, and portability, making them essential for timely monitoring of various analytes. The performance of electrochemical sensor is further boosted by integrating materials such as spinels, metal oxides, and metallic nanoparticles. These materials are broadly investigated as electrode interface components thanks to their features that collectively boost electrochemical sensor such as providing excellent electrical conductivity, distinct catalytic behavior, and larger surface areas. Furthermore, this paper reviews the impact of traditional and standards analytical methods, as well as their recent advancement based on the detection of CAP in aqueous media.</div></div>\",\"PeriodicalId\":436,\"journal\":{\"name\":\"Talanta Open\",\"volume\":\"12 \",\"pages\":\"Article 100561\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2025-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666831925001626\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831925001626","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

氯霉素(CAP)已被证明对细菌感染具有广泛的有效性。然而,它在环境中的持久性和潜在的毒性导致严格的全球法规限制其使用。因此,正在开发快速和准确的CAP检测方法,以保护公众健康并保持其在环境中存在的法规遵从性。高效液相色谱法、气相色谱法、液相色谱-质谱法等常规分析方法是CAP检测常用的方法。然而,这些传统方法面临着诸如耗时、制造复杂性、可重复性和成本等挑战。随着电化学传感技术呈现出各种有价值的优点,如即时检测,低功耗,同时分析和便携性,使其成为及时监测各种分析物的必要条件。尖晶石、金属氧化物、金属纳米颗粒等材料的集成进一步提高了电化学传感器的性能。这些材料作为电极界面组件被广泛研究,这要归功于它们共同提升电化学传感器的特性,如提供优异的导电性、独特的催化行为和更大的表面积。此外,本文综述了传统分析方法和标准分析方法的影响,以及基于水介质中CAP检测的最新进展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Advancement in electrochemical sensing of chloramphenicol in varying matrixes: A review

Advancement in electrochemical sensing of chloramphenicol in varying matrixes: A review
Chloramphenicol (CAP) have demonstrated its broad effectiveness against bacterial infections. However, its persistence in the environment and potential toxicity led to strict global regulations limiting its use. As a result, rapid and accurate detection methods for CAP are being developed to protect public health and maintain regulatory compliance regarding its presence in the environment. Conventional analytical methods such as High-Performance Liquid Chromatography, Gas Chromatography, and Liquid Chromatography–Mass Spectrometry were commonly used for CAP detection. However, these conventional methods suffer challenges such as time-consumption, fabrication complexity, reproducibility, and cost. With electrochemical sensing techniques presenting varying valuable benefits, such as instant detection, low power consumption, simultaneous analysis, and portability, making them essential for timely monitoring of various analytes. The performance of electrochemical sensor is further boosted by integrating materials such as spinels, metal oxides, and metallic nanoparticles. These materials are broadly investigated as electrode interface components thanks to their features that collectively boost electrochemical sensor such as providing excellent electrical conductivity, distinct catalytic behavior, and larger surface areas. Furthermore, this paper reviews the impact of traditional and standards analytical methods, as well as their recent advancement based on the detection of CAP in aqueous media.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Talanta Open
Talanta Open Chemistry-Analytical Chemistry
CiteScore
5.20
自引率
0.00%
发文量
86
审稿时长
49 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信