{"title":"体外评估骨内新加载牙种植体脱位所需的力。","authors":"Paulami Bagchi, Savita Hadakar, Ruchi Agrawal, Snehamoy Pradhan, Vikas Gupta, Arjun Kumar Sharma, Miral Mehta","doi":"10.6026/973206300211522","DOIUrl":null,"url":null,"abstract":"<p><p>The mechanical force required to luxate newly loaded dental implants using synthetic bone blocks simulating D2 density is of interest. The average luxation force was 184.7 ± 12.3 N. Implants inserted with higher torque showed slightly greater resistance, though not statistically significant (p > 0.05). Results suggest moderate resistance to early implant removal. These findings may aid clinicians in planning safe implant retrieval procedures.</p>","PeriodicalId":8962,"journal":{"name":"Bioinformation","volume":"21 6","pages":"1522-1525"},"PeriodicalIF":1.9000,"publicationDate":"2025-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12449541/pdf/","citationCount":"0","resultStr":"{\"title\":\"<i>in vitro</i> evaluation of force required to luxate a newly loaded dental implant in bone.\",\"authors\":\"Paulami Bagchi, Savita Hadakar, Ruchi Agrawal, Snehamoy Pradhan, Vikas Gupta, Arjun Kumar Sharma, Miral Mehta\",\"doi\":\"10.6026/973206300211522\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The mechanical force required to luxate newly loaded dental implants using synthetic bone blocks simulating D2 density is of interest. The average luxation force was 184.7 ± 12.3 N. Implants inserted with higher torque showed slightly greater resistance, though not statistically significant (p > 0.05). Results suggest moderate resistance to early implant removal. These findings may aid clinicians in planning safe implant retrieval procedures.</p>\",\"PeriodicalId\":8962,\"journal\":{\"name\":\"Bioinformation\",\"volume\":\"21 6\",\"pages\":\"1522-1525\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12449541/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioinformation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.6026/973206300211522\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioinformation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6026/973206300211522","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
in vitro evaluation of force required to luxate a newly loaded dental implant in bone.
The mechanical force required to luxate newly loaded dental implants using synthetic bone blocks simulating D2 density is of interest. The average luxation force was 184.7 ± 12.3 N. Implants inserted with higher torque showed slightly greater resistance, though not statistically significant (p > 0.05). Results suggest moderate resistance to early implant removal. These findings may aid clinicians in planning safe implant retrieval procedures.