RAON重离子加速器横向相空间层析成像及与艾利森扫描仪数据的比较

IF 1.4 3区 物理与天体物理 Q3 INSTRUMENTS & INSTRUMENTATION
Dong-O Jeon , Ji-Ho Jang , Jean-Baptiste Lallement , Veliko Dimov
{"title":"RAON重离子加速器横向相空间层析成像及与艾利森扫描仪数据的比较","authors":"Dong-O Jeon ,&nbsp;Ji-Ho Jang ,&nbsp;Jean-Baptiste Lallement ,&nbsp;Veliko Dimov","doi":"10.1016/j.nima.2025.171005","DOIUrl":null,"url":null,"abstract":"<div><div>Tomographic phase space reconstruction method based on the beam dynamics code Travel is applied to the RAON linear accelerator in the LEBT and in the MEBT. Due to the low beam energy and the two dipoles in the LEBT, it matters to include the space charge effect and the second-order effects of dipoles. When compared with the Allison scanner emittance data in the LEBT, the phase space tomography demonstrates a very good agreement even though the actual beam is far from Gaussian. The method of fitting rms beam sizes of wire scanners is also compared with the phase space tomography method. The method of fitting rms beam sizes produces a very good agreement when the actual beam is close to Gaussian, because the beam size fitting method uses Gaussian input beam in the simulation.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1082 ","pages":"Article 171005"},"PeriodicalIF":1.4000,"publicationDate":"2025-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transverse phase space tomography and comparison with Allison scanner data in the RAON heavy ion accelerator\",\"authors\":\"Dong-O Jeon ,&nbsp;Ji-Ho Jang ,&nbsp;Jean-Baptiste Lallement ,&nbsp;Veliko Dimov\",\"doi\":\"10.1016/j.nima.2025.171005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Tomographic phase space reconstruction method based on the beam dynamics code Travel is applied to the RAON linear accelerator in the LEBT and in the MEBT. Due to the low beam energy and the two dipoles in the LEBT, it matters to include the space charge effect and the second-order effects of dipoles. When compared with the Allison scanner emittance data in the LEBT, the phase space tomography demonstrates a very good agreement even though the actual beam is far from Gaussian. The method of fitting rms beam sizes of wire scanners is also compared with the phase space tomography method. The method of fitting rms beam sizes produces a very good agreement when the actual beam is close to Gaussian, because the beam size fitting method uses Gaussian input beam in the simulation.</div></div>\",\"PeriodicalId\":19359,\"journal\":{\"name\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"volume\":\"1082 \",\"pages\":\"Article 171005\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0168900225008071\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168900225008071","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

将基于束动力学代码Travel的层析相空间重构方法应用于LEBT和MEBT中的RAON直线加速器。由于束流能量较低,且LEBT中存在双偶极子,因此考虑空间电荷效应和偶极子的二阶效应很重要。当与LEBT中的艾利森扫描仪发射度数据进行比较时,相空间层析成像显示出非常好的一致性,即使实际光束远离高斯。本文还比较了相空间层析成像法与线扫描仪光束均方根尺寸的拟合方法。由于光束尺寸拟合方法在模拟中使用的是高斯输入光束,因此在实际光束接近高斯的情况下,光束均方根尺寸拟合方法的一致性非常好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transverse phase space tomography and comparison with Allison scanner data in the RAON heavy ion accelerator
Tomographic phase space reconstruction method based on the beam dynamics code Travel is applied to the RAON linear accelerator in the LEBT and in the MEBT. Due to the low beam energy and the two dipoles in the LEBT, it matters to include the space charge effect and the second-order effects of dipoles. When compared with the Allison scanner emittance data in the LEBT, the phase space tomography demonstrates a very good agreement even though the actual beam is far from Gaussian. The method of fitting rms beam sizes of wire scanners is also compared with the phase space tomography method. The method of fitting rms beam sizes produces a very good agreement when the actual beam is close to Gaussian, because the beam size fitting method uses Gaussian input beam in the simulation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
21.40%
发文量
787
审稿时长
1 months
期刊介绍: Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section. Theoretical as well as experimental papers are accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信