{"title":"高热流密度非均质材料集成模具CVD金刚石微通道冷却的实验与数值研究","authors":"Xinrui Zhang ,&nbsp;Linwei Cao ,&nbsp;Wei He ,&nbsp;Qiang Li ,&nbsp;Quanfeng Zhou ,&nbsp;Dinghua Hu","doi":"10.1016/j.ijheatmasstransfer.2025.127836","DOIUrl":null,"url":null,"abstract":"<div><div>With the continuous advancement of integrated circuits toward higher integration and power density, thermal management of chips faces significant challenges. This study proposes a heterogeneous material -integrated cooling scheme based on chemical vapor deposition diamond microchannels (CVD-DMCs) and systematically investigates its heat transfer performance under ultra-high heat flux conditions through combined simulation and experimental methods. Initially, a comparative simulation analysis was conducted for different rib structures with rectangular, circular and rhombic cross-sections. The rhombic rib was identified as the optimal configuration, with rib depth (D) and width (W) as key geometric parameters. A non-uniform multi-heat-source test die incorporating dual large-area and multi-point small-area Pt films was fabricated and bonded, via AuSn eutectic bonding, to a femtosecond laser-machined CVD-DMC structure mounted on an AlN substrate, forming a complete test model. Experimental results under extreme conditions of 144 mL/min flow rate, heat fluxes of 1100 W/cm² (dual large-area) and 11000 W/cm² (multi-point small-area) demonstrated that the rhombic rib structure with a D of 0.5 mm, W of 0.15 mm achieved the best cooling performance among the structures investigated in this study. lowering die temperature to 108 °C with a pressure drop (<em>ΔP</em>) of 11.22 kPa. Further analysis indicated that optimizing rib width is more effective than rib depth in enhancing heat transfer while minimizing flow resistance. Moreover, the feasibility and accuracy of integrating multi-point small-area for localized heating and temperature measurement at the chip level were verified. This work reveals the critical influence of CVD-DMCs rib structures on thermal performance and proposes an efficient integrated cooling design for high heat flux electronic devices.</div></div>","PeriodicalId":336,"journal":{"name":"International Journal of Heat and Mass Transfer","volume":"255 ","pages":"Article 127836"},"PeriodicalIF":5.8000,"publicationDate":"2025-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental and numerical study of CVD diamond microchannel cooling for high heat flux heterogeneous material-integrated dies\",\"authors\":\"Xinrui Zhang ,&nbsp;Linwei Cao ,&nbsp;Wei He ,&nbsp;Qiang Li ,&nbsp;Quanfeng Zhou ,&nbsp;Dinghua Hu\",\"doi\":\"10.1016/j.ijheatmasstransfer.2025.127836\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>With the continuous advancement of integrated circuits toward higher integration and power density, thermal management of chips faces significant challenges. This study proposes a heterogeneous material -integrated cooling scheme based on chemical vapor deposition diamond microchannels (CVD-DMCs) and systematically investigates its heat transfer performance under ultra-high heat flux conditions through combined simulation and experimental methods. Initially, a comparative simulation analysis was conducted for different rib structures with rectangular, circular and rhombic cross-sections. The rhombic rib was identified as the optimal configuration, with rib depth (D) and width (W) as key geometric parameters. A non-uniform multi-heat-source test die incorporating dual large-area and multi-point small-area Pt films was fabricated and bonded, via AuSn eutectic bonding, to a femtosecond laser-machined CVD-DMC structure mounted on an AlN substrate, forming a complete test model. Experimental results under extreme conditions of 144 mL/min flow rate, heat fluxes of 1100 W/cm² (dual large-area) and 11000 W/cm² (multi-point small-area) demonstrated that the rhombic rib structure with a D of 0.5 mm, W of 0.15 mm achieved the best cooling performance among the structures investigated in this study. lowering die temperature to 108 °C with a pressure drop (<em>ΔP</em>) of 11.22 kPa. Further analysis indicated that optimizing rib width is more effective than rib depth in enhancing heat transfer while minimizing flow resistance. Moreover, the feasibility and accuracy of integrating multi-point small-area for localized heating and temperature measurement at the chip level were verified. This work reveals the critical influence of CVD-DMCs rib structures on thermal performance and proposes an efficient integrated cooling design for high heat flux electronic devices.</div></div>\",\"PeriodicalId\":336,\"journal\":{\"name\":\"International Journal of Heat and Mass Transfer\",\"volume\":\"255 \",\"pages\":\"Article 127836\"},\"PeriodicalIF\":5.8000,\"publicationDate\":\"2025-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Heat and Mass Transfer\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0017931025011718\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Heat and Mass Transfer","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0017931025011718","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

随着集成电路向更高集成度和功率密度的不断发展,芯片的热管理面临着重大挑战。本研究提出了一种基于化学气相沉积金刚石微通道(CVD-DMCs)的非均质材料集成冷却方案,并通过模拟与实验相结合的方法系统研究了其在超高热流密度条件下的换热性能。首先,对矩形截面、圆形截面和菱形截面的肋结构进行了对比仿真分析。以肋深(D)和肋宽(W)为关键几何参数,确定了菱形肋为最优构型。制作了包含双大面积和多点小面积Pt薄膜的非均匀多热源测试模具,并通过AuSn共晶键合与安装在AlN衬底上的飞秒激光加工CVD-DMC结构相结合,形成了完整的测试模型。在144 mL/min流速、1100w /cm²(双大面积)和11000w /cm²(多点小面积)的极端条件下,实验结果表明,D为0.5 mm、W为0.15 mm的菱形肋条结构具有最佳的冷却性能。降低模具温度至108°C,压降(ΔP)为11.22 kPa。进一步分析表明,优化肋宽比优化肋深更能有效地提高传热效果,同时减小流动阻力。验证了多点小面积集成在芯片级局部加热测温的可行性和准确性。本研究揭示了CVD-DMCs肋结构对热工性能的重要影响,提出了一种高效的高热流密度电子器件集成冷却设计方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental and numerical study of CVD diamond microchannel cooling for high heat flux heterogeneous material-integrated dies
With the continuous advancement of integrated circuits toward higher integration and power density, thermal management of chips faces significant challenges. This study proposes a heterogeneous material -integrated cooling scheme based on chemical vapor deposition diamond microchannels (CVD-DMCs) and systematically investigates its heat transfer performance under ultra-high heat flux conditions through combined simulation and experimental methods. Initially, a comparative simulation analysis was conducted for different rib structures with rectangular, circular and rhombic cross-sections. The rhombic rib was identified as the optimal configuration, with rib depth (D) and width (W) as key geometric parameters. A non-uniform multi-heat-source test die incorporating dual large-area and multi-point small-area Pt films was fabricated and bonded, via AuSn eutectic bonding, to a femtosecond laser-machined CVD-DMC structure mounted on an AlN substrate, forming a complete test model. Experimental results under extreme conditions of 144 mL/min flow rate, heat fluxes of 1100 W/cm² (dual large-area) and 11000 W/cm² (multi-point small-area) demonstrated that the rhombic rib structure with a D of 0.5 mm, W of 0.15 mm achieved the best cooling performance among the structures investigated in this study. lowering die temperature to 108 °C with a pressure drop (ΔP) of 11.22 kPa. Further analysis indicated that optimizing rib width is more effective than rib depth in enhancing heat transfer while minimizing flow resistance. Moreover, the feasibility and accuracy of integrating multi-point small-area for localized heating and temperature measurement at the chip level were verified. This work reveals the critical influence of CVD-DMCs rib structures on thermal performance and proposes an efficient integrated cooling design for high heat flux electronic devices.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
10.30
自引率
13.50%
发文量
1319
审稿时长
41 days
期刊介绍: International Journal of Heat and Mass Transfer is the vehicle for the exchange of basic ideas in heat and mass transfer between research workers and engineers throughout the world. It focuses on both analytical and experimental research, with an emphasis on contributions which increase the basic understanding of transfer processes and their application to engineering problems. Topics include: -New methods of measuring and/or correlating transport-property data -Energy engineering -Environmental applications of heat and/or mass transfer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信