27号微切口玻璃体切除术辅助人工晶状体巩膜固定:前段光学相干断层扫描引导下的研究。

IF 1.8 4区 医学 Q2 OPHTHALMOLOGY
Ashish Markan, Manasi Tripathi, Shivani Chhabra, Vipin Rana
{"title":"27号微切口玻璃体切除术辅助人工晶状体巩膜固定:前段光学相干断层扫描引导下的研究。","authors":"Ashish Markan, Manasi Tripathi, Shivani Chhabra, Vipin Rana","doi":"10.4103/IJO.IJO_1102_25","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the outcomes of 27-gauge (27G) microincision vitrectomy surgery (MIVS)-assisted scleral fixation of intraocular lenses (SFIOLs) using anterior segment optical coherence tomography (AS-OCT). The study assesses postoperative intraocular lens (IOL) tilt, decentration, and iris to IOL distance and their impact on visual and refractive outcomes.</p><p><strong>Methods: </strong>This retrospective study included 36 patients undergoing 27G MIVS-assisted SFIOL implantation. Preoperative data, including best-corrected visual acuity (BCVA), intraocular pressure (IOP), endothelial cell count, and surgical indications, were recorded. Postoperatively, BCVA, IOP, and endothelial cell count were assessed at 3 months. Additionally, postoperative AS-OCT was performed to assess IOL tilt, decentration, and distance of the IOL from the posterior iris surface. Surgical complications were documented.</p><p><strong>Results: </strong>The mean IOL tilt was 3.58 ± 0.57 degrees, IOL decentration was 0.22 ± 0.47 mm, and IOL to posterior iris distance was 0.76 ± 0.66 mm. At three months, BCVA significantly improved from 0.85 ± 0.53 log MAR to 0.38 ± 0.38 log MAR (P = 0.03). Hyperopic shift (manifest refractive spherical equivalent [MRSE]: +1.14 ± 0.62 D) correlated strongly with increased distance of IOL from the posterior iris surface. Complications included early postoperative IOL tilt (n = 4, requiring refixation), vitreous hemorrhage (n = 3, resolving spontaneously), and choroidal detachment (n = 2, resolving with corticosteroids).</p><p><strong>Conclusions: </strong>The 27G MIVS-assisted SFIOL technique demonstrates favorable outcomes with minimal IOL tilt and decentration. The technique offers a safe and effective alternative for scleral fixation, optimizing surgical efficiency and patient outcomes.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"27-gauge microincision vitrectomy surgery-assisted scleral fixation of intraocular lens: An anterior segment optical coherence tomography-guided study.\",\"authors\":\"Ashish Markan, Manasi Tripathi, Shivani Chhabra, Vipin Rana\",\"doi\":\"10.4103/IJO.IJO_1102_25\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the outcomes of 27-gauge (27G) microincision vitrectomy surgery (MIVS)-assisted scleral fixation of intraocular lenses (SFIOLs) using anterior segment optical coherence tomography (AS-OCT). The study assesses postoperative intraocular lens (IOL) tilt, decentration, and iris to IOL distance and their impact on visual and refractive outcomes.</p><p><strong>Methods: </strong>This retrospective study included 36 patients undergoing 27G MIVS-assisted SFIOL implantation. Preoperative data, including best-corrected visual acuity (BCVA), intraocular pressure (IOP), endothelial cell count, and surgical indications, were recorded. Postoperatively, BCVA, IOP, and endothelial cell count were assessed at 3 months. Additionally, postoperative AS-OCT was performed to assess IOL tilt, decentration, and distance of the IOL from the posterior iris surface. Surgical complications were documented.</p><p><strong>Results: </strong>The mean IOL tilt was 3.58 ± 0.57 degrees, IOL decentration was 0.22 ± 0.47 mm, and IOL to posterior iris distance was 0.76 ± 0.66 mm. At three months, BCVA significantly improved from 0.85 ± 0.53 log MAR to 0.38 ± 0.38 log MAR (P = 0.03). Hyperopic shift (manifest refractive spherical equivalent [MRSE]: +1.14 ± 0.62 D) correlated strongly with increased distance of IOL from the posterior iris surface. Complications included early postoperative IOL tilt (n = 4, requiring refixation), vitreous hemorrhage (n = 3, resolving spontaneously), and choroidal detachment (n = 2, resolving with corticosteroids).</p><p><strong>Conclusions: </strong>The 27G MIVS-assisted SFIOL technique demonstrates favorable outcomes with minimal IOL tilt and decentration. The technique offers a safe and effective alternative for scleral fixation, optimizing surgical efficiency and patient outcomes.</p>\",\"PeriodicalId\":13329,\"journal\":{\"name\":\"Indian Journal of Ophthalmology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4103/IJO.IJO_1102_25\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_1102_25","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:应用前段光学相干断层扫描(AS-OCT)评价27口径(27G)微切口玻璃体切除术(MIVS)辅助巩膜固定人工晶状体(SFIOLs)的效果。该研究评估了术后人工晶状体(IOL)倾斜、离体、虹膜与IOL的距离及其对视力和屈光结果的影响。方法:回顾性研究36例接受27G mivs辅助SFIOL植入术的患者。记录术前数据,包括最佳矫正视力(BCVA)、眼内压(IOP)、内皮细胞计数和手术指征。术后3个月评估BCVA、IOP和内皮细胞计数。此外,术后进行AS-OCT评估人工晶状体的倾斜、离体以及离虹膜后表面的距离。记录了手术并发症。结果:人工晶状体平均倾斜3.58±0.57度,离体0.22±0.47 mm,距虹膜后距离0.76±0.66 mm。3个月时,BCVA从0.85±0.53 log MAR显著改善至0.38±0.38 log MAR (P = 0.03)。远视位移(明显屈光球当量[MRSE]: +1.14±0.62 D)与人工晶体距虹膜后表面的距离增加密切相关。并发症包括术后早期IOL倾斜(n = 4,需要重新固定),玻璃体出血(n = 3,自发消退)和脉络膜脱离(n = 2,使用皮质类固醇消退)。结论:27G mivs辅助下的SFIOL技术具有良好的效果,人工晶状体倾斜和脱位最小。该技术为巩膜固定提供了一种安全有效的替代方法,优化了手术效率和患者预后。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
27-gauge microincision vitrectomy surgery-assisted scleral fixation of intraocular lens: An anterior segment optical coherence tomography-guided study.

Purpose: To evaluate the outcomes of 27-gauge (27G) microincision vitrectomy surgery (MIVS)-assisted scleral fixation of intraocular lenses (SFIOLs) using anterior segment optical coherence tomography (AS-OCT). The study assesses postoperative intraocular lens (IOL) tilt, decentration, and iris to IOL distance and their impact on visual and refractive outcomes.

Methods: This retrospective study included 36 patients undergoing 27G MIVS-assisted SFIOL implantation. Preoperative data, including best-corrected visual acuity (BCVA), intraocular pressure (IOP), endothelial cell count, and surgical indications, were recorded. Postoperatively, BCVA, IOP, and endothelial cell count were assessed at 3 months. Additionally, postoperative AS-OCT was performed to assess IOL tilt, decentration, and distance of the IOL from the posterior iris surface. Surgical complications were documented.

Results: The mean IOL tilt was 3.58 ± 0.57 degrees, IOL decentration was 0.22 ± 0.47 mm, and IOL to posterior iris distance was 0.76 ± 0.66 mm. At three months, BCVA significantly improved from 0.85 ± 0.53 log MAR to 0.38 ± 0.38 log MAR (P = 0.03). Hyperopic shift (manifest refractive spherical equivalent [MRSE]: +1.14 ± 0.62 D) correlated strongly with increased distance of IOL from the posterior iris surface. Complications included early postoperative IOL tilt (n = 4, requiring refixation), vitreous hemorrhage (n = 3, resolving spontaneously), and choroidal detachment (n = 2, resolving with corticosteroids).

Conclusions: The 27G MIVS-assisted SFIOL technique demonstrates favorable outcomes with minimal IOL tilt and decentration. The technique offers a safe and effective alternative for scleral fixation, optimizing surgical efficiency and patient outcomes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.80
自引率
19.40%
发文量
1963
审稿时长
38 weeks
期刊介绍: Indian Journal of Ophthalmology covers clinical, experimental, basic science research and translational research studies related to medical, ethical and social issues in field of ophthalmology and vision science. Articles with clinical interest and implications will be given preference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信