肩外装对神经损伤患者运动范围、耐力和任务执行的影响。

IF 2.8 Q2 ENGINEERING, BIOMEDICAL
Wearable technologies Pub Date : 2025-08-11 eCollection Date: 2025-01-01 DOI:10.1017/wtc.2025.10024
Adrian Esser, Fabian Müller, Julia Manczurowsky, Christopher J Hasson, Tim Unger, Chris Easthope Awai, Peter Wolf, Robert Riener
{"title":"肩外装对神经损伤患者运动范围、耐力和任务执行的影响。","authors":"Adrian Esser, Fabian Müller, Julia Manczurowsky, Christopher J Hasson, Tim Unger, Chris Easthope Awai, Peter Wolf, Robert Riener","doi":"10.1017/wtc.2025.10024","DOIUrl":null,"url":null,"abstract":"<p><p>The Myoshirt, an active exosuit, provides gravity compensation for the shoulders. This study evaluated the impact of the Myoshirt on range of motion (ROM), endurance, and activities of daily living (ADLs) performance through tests involving nine participants with varying levels of arm impairments and diverse pathologies. Optical motion capture was used to quantify ROM of the shoulder and elbow joints during isolated movements and functional tasks. Endurance was quantified through a timed isometric shoulder flexion task, and a battery of ADL tasks was used to measure the perceived support of the exosuit, along with changes in movement quality. Feedback and usability insights were gathered with surveys. The Myoshirt did not significantly improve ROM during isolated movements (shoulder flexion, shoulder abduction, and elbow flexion/extension), but during the reaching phase of a functional drinking task elbow extension increased significantly by 13.5% (t = 7.52, p = .002). Participants could also keep their arms elevated 78.7% longer (t = 1.942, p = .047). Patients also reported less perceived difficulty with ADLs while using the device, and a therapist reported improved execution quality. Participants who self-reported severe impairment levels tended to derive greater benefits compared to those with milder impairments. These findings highlight the potential of the Myoshirt as an assistive device, particularly for individuals with severe impairments, while emphasizing the need for further refinement.</p>","PeriodicalId":75318,"journal":{"name":"Wearable technologies","volume":"6 ","pages":"e42"},"PeriodicalIF":2.8000,"publicationDate":"2025-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12441642/pdf/","citationCount":"0","resultStr":"{\"title\":\"Impact of a shoulder exosuit on range of motion, endurance, and task execution in users with neurological impairments.\",\"authors\":\"Adrian Esser, Fabian Müller, Julia Manczurowsky, Christopher J Hasson, Tim Unger, Chris Easthope Awai, Peter Wolf, Robert Riener\",\"doi\":\"10.1017/wtc.2025.10024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The Myoshirt, an active exosuit, provides gravity compensation for the shoulders. This study evaluated the impact of the Myoshirt on range of motion (ROM), endurance, and activities of daily living (ADLs) performance through tests involving nine participants with varying levels of arm impairments and diverse pathologies. Optical motion capture was used to quantify ROM of the shoulder and elbow joints during isolated movements and functional tasks. Endurance was quantified through a timed isometric shoulder flexion task, and a battery of ADL tasks was used to measure the perceived support of the exosuit, along with changes in movement quality. Feedback and usability insights were gathered with surveys. The Myoshirt did not significantly improve ROM during isolated movements (shoulder flexion, shoulder abduction, and elbow flexion/extension), but during the reaching phase of a functional drinking task elbow extension increased significantly by 13.5% (t = 7.52, p = .002). Participants could also keep their arms elevated 78.7% longer (t = 1.942, p = .047). Patients also reported less perceived difficulty with ADLs while using the device, and a therapist reported improved execution quality. Participants who self-reported severe impairment levels tended to derive greater benefits compared to those with milder impairments. These findings highlight the potential of the Myoshirt as an assistive device, particularly for individuals with severe impairments, while emphasizing the need for further refinement.</p>\",\"PeriodicalId\":75318,\"journal\":{\"name\":\"Wearable technologies\",\"volume\":\"6 \",\"pages\":\"e42\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2025-08-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12441642/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wearable technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1017/wtc.2025.10024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wearable technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/wtc.2025.10024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

Myoshirt是一种主动外骨骼服,为肩膀提供重力补偿。本研究评估了Myoshirt对活动范围(ROM)、耐力和日常生活活动(adl)表现的影响,涉及9名不同程度手臂损伤和不同病理的参与者。光学运动捕捉用于量化孤立运动和功能性任务期间肩关节和肘关节的ROM。耐力通过定时等距肩部屈曲任务来量化,并使用一系列ADL任务来测量外服的感知支撑,以及运动质量的变化。反馈和可用性见解是通过调查收集的。Myoshirt在孤立运动(肩屈、肩外展和肘关节屈伸)期间没有显著改善ROM,但在功能性饮酒任务的到达阶段,肘关节伸直显著增加13.5% (t = 7.52, p = 0.002)。参与者还可以将手臂高举的时间延长78.7% (t = 1.942, p = 0.047)。患者还报告说,在使用该设备时,adl的感知困难减少了,一位治疗师报告说,执行质量得到了提高。自我报告严重损伤水平的参与者往往比那些损伤较轻的参与者获得更大的好处。这些发现强调了Myoshirt作为辅助设备的潜力,特别是对于严重损伤的个体,同时强调了进一步改进的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of a shoulder exosuit on range of motion, endurance, and task execution in users with neurological impairments.

The Myoshirt, an active exosuit, provides gravity compensation for the shoulders. This study evaluated the impact of the Myoshirt on range of motion (ROM), endurance, and activities of daily living (ADLs) performance through tests involving nine participants with varying levels of arm impairments and diverse pathologies. Optical motion capture was used to quantify ROM of the shoulder and elbow joints during isolated movements and functional tasks. Endurance was quantified through a timed isometric shoulder flexion task, and a battery of ADL tasks was used to measure the perceived support of the exosuit, along with changes in movement quality. Feedback and usability insights were gathered with surveys. The Myoshirt did not significantly improve ROM during isolated movements (shoulder flexion, shoulder abduction, and elbow flexion/extension), but during the reaching phase of a functional drinking task elbow extension increased significantly by 13.5% (t = 7.52, p = .002). Participants could also keep their arms elevated 78.7% longer (t = 1.942, p = .047). Patients also reported less perceived difficulty with ADLs while using the device, and a therapist reported improved execution quality. Participants who self-reported severe impairment levels tended to derive greater benefits compared to those with milder impairments. These findings highlight the potential of the Myoshirt as an assistive device, particularly for individuals with severe impairments, while emphasizing the need for further refinement.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.80
自引率
0.00%
发文量
0
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信