Thomas J Vogl, Hamzah Adwan, Leonhard Mann, Ibrahem Al Haj Ibrahem
{"title":"经皮ct引导下胰腺活检的准确性和安全性。","authors":"Thomas J Vogl, Hamzah Adwan, Leonhard Mann, Ibrahem Al Haj Ibrahem","doi":"10.1007/s11547-025-02087-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the accuracy and safety of CT-guided percutaneous core-needle biopsies of pancreatic lesions suspected to be malignant based on MRI or CT scans.</p><p><strong>Materials and methods: </strong>This retrospective study analyzed CT-guided percutaneous biopsies of suspicious pancreatic lesions performed at our university hospital. Biopsy was performed using a 17G coaxial needle and an 18G core biopsy needle. Data on patient characteristics, lesions, procedures, and histologic results were recorded.</p><p><strong>Results: </strong>A total of 90 patients (58.9% males, mean age 65 ± 12.2 years) underwent CT-guided percutaneous biopsies. The lesions had a mean size of 36.8 ± 12.2 mm and were predominantly located in the pancreatic head 61.1% (55/90). Technical success was achieved in all biopsies 100% (90/90). Most procedures 96.7% (87/90) were performed using direct access routes, while 3.3% (3/90) required indirect transhepatic or transgastric approaches. Among the biopsies, 65.6% (59/90) confirmed malignancy, with adenocarcinoma as the most common malignant subtype representing 55.6% (50/90) of all cases. The rate of non-malignant findings was 26.7% (24/90) including chronic pancreatitis at a rate of 5.6% (5/90) as well as pancreatic pseudocysts and pancreatic cystadenoma each at a rate of 2.2% (2/90), among others. A total of seven cases were identified as false negatives confirmed, but malignancy was later confirmed after re-biopsy or surgery. The initial diagnostic accuracy was 92.2% (83/90). The rate of major complications was 1.1% (1/90), and a total of two minor complications at a rate of 2.2% were observed.</p><p><strong>Conclusion: </strong>This study shows that CT-guided pancreatic biopsy is a safe procedure with high diagnostic accuracy.</p>","PeriodicalId":20817,"journal":{"name":"Radiologia Medica","volume":" ","pages":""},"PeriodicalIF":4.8000,"publicationDate":"2025-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy and safety of percutaneous CT-guided pancreatic biopsies.\",\"authors\":\"Thomas J Vogl, Hamzah Adwan, Leonhard Mann, Ibrahem Al Haj Ibrahem\",\"doi\":\"10.1007/s11547-025-02087-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess the accuracy and safety of CT-guided percutaneous core-needle biopsies of pancreatic lesions suspected to be malignant based on MRI or CT scans.</p><p><strong>Materials and methods: </strong>This retrospective study analyzed CT-guided percutaneous biopsies of suspicious pancreatic lesions performed at our university hospital. Biopsy was performed using a 17G coaxial needle and an 18G core biopsy needle. Data on patient characteristics, lesions, procedures, and histologic results were recorded.</p><p><strong>Results: </strong>A total of 90 patients (58.9% males, mean age 65 ± 12.2 years) underwent CT-guided percutaneous biopsies. The lesions had a mean size of 36.8 ± 12.2 mm and were predominantly located in the pancreatic head 61.1% (55/90). Technical success was achieved in all biopsies 100% (90/90). Most procedures 96.7% (87/90) were performed using direct access routes, while 3.3% (3/90) required indirect transhepatic or transgastric approaches. Among the biopsies, 65.6% (59/90) confirmed malignancy, with adenocarcinoma as the most common malignant subtype representing 55.6% (50/90) of all cases. The rate of non-malignant findings was 26.7% (24/90) including chronic pancreatitis at a rate of 5.6% (5/90) as well as pancreatic pseudocysts and pancreatic cystadenoma each at a rate of 2.2% (2/90), among others. A total of seven cases were identified as false negatives confirmed, but malignancy was later confirmed after re-biopsy or surgery. The initial diagnostic accuracy was 92.2% (83/90). The rate of major complications was 1.1% (1/90), and a total of two minor complications at a rate of 2.2% were observed.</p><p><strong>Conclusion: </strong>This study shows that CT-guided pancreatic biopsy is a safe procedure with high diagnostic accuracy.</p>\",\"PeriodicalId\":20817,\"journal\":{\"name\":\"Radiologia Medica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2025-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiologia Medica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11547-025-02087-8\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11547-025-02087-8","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Accuracy and safety of percutaneous CT-guided pancreatic biopsies.
Purpose: To assess the accuracy and safety of CT-guided percutaneous core-needle biopsies of pancreatic lesions suspected to be malignant based on MRI or CT scans.
Materials and methods: This retrospective study analyzed CT-guided percutaneous biopsies of suspicious pancreatic lesions performed at our university hospital. Biopsy was performed using a 17G coaxial needle and an 18G core biopsy needle. Data on patient characteristics, lesions, procedures, and histologic results were recorded.
Results: A total of 90 patients (58.9% males, mean age 65 ± 12.2 years) underwent CT-guided percutaneous biopsies. The lesions had a mean size of 36.8 ± 12.2 mm and were predominantly located in the pancreatic head 61.1% (55/90). Technical success was achieved in all biopsies 100% (90/90). Most procedures 96.7% (87/90) were performed using direct access routes, while 3.3% (3/90) required indirect transhepatic or transgastric approaches. Among the biopsies, 65.6% (59/90) confirmed malignancy, with adenocarcinoma as the most common malignant subtype representing 55.6% (50/90) of all cases. The rate of non-malignant findings was 26.7% (24/90) including chronic pancreatitis at a rate of 5.6% (5/90) as well as pancreatic pseudocysts and pancreatic cystadenoma each at a rate of 2.2% (2/90), among others. A total of seven cases were identified as false negatives confirmed, but malignancy was later confirmed after re-biopsy or surgery. The initial diagnostic accuracy was 92.2% (83/90). The rate of major complications was 1.1% (1/90), and a total of two minor complications at a rate of 2.2% were observed.
Conclusion: This study shows that CT-guided pancreatic biopsy is a safe procedure with high diagnostic accuracy.
期刊介绍:
Felice Perussia founded La radiologia medica in 1914. It is a peer-reviewed journal and serves as the official journal of the Italian Society of Medical and Interventional Radiology (SIRM). The primary purpose of the journal is to disseminate information related to Radiology, especially advancements in diagnostic imaging and related disciplines. La radiologia medica welcomes original research on both fundamental and clinical aspects of modern radiology, with a particular focus on diagnostic and interventional imaging techniques. It also covers topics such as radiotherapy, nuclear medicine, radiobiology, health physics, and artificial intelligence in the context of clinical implications. The journal includes various types of contributions such as original articles, review articles, editorials, short reports, and letters to the editor. With an esteemed Editorial Board and a selection of insightful reports, the journal is an indispensable resource for radiologists and professionals in related fields. Ultimately, La radiologia medica aims to serve as a platform for international collaboration and knowledge sharing within the radiological community.