多频生物电阻抗分析(MFBIA)用于测量健康体力活动人群身体成分的实际评估。

IF 3.3 3区 医学 Q2 NUTRITION & DIETETICS
Adam W Potter, Leigh C Ward, Christopher L Chapman, William J Tharion, David P Looney, Karl E Friedl
{"title":"多频生物电阻抗分析(MFBIA)用于测量健康体力活动人群身体成分的实际评估。","authors":"Adam W Potter, Leigh C Ward, Christopher L Chapman, William J Tharion, David P Looney, Karl E Friedl","doi":"10.1038/s41430-025-01664-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Multi-frequency bioelectrical impedance analysis (MFBIA) methods offer reliable and moderately accurate estimates of body composition in tightly controlled conditions (prandial and hydration status, recent exercise, time of day).</p><p><strong>Objective: </strong>This study examined MFBIA reliability and validity in a real-world environment where these factors were not controlled.</p><p><strong>Methods: </strong>Regional and total body composition estimates by MFBIA (InBody 770) were compared to dual-energy X-ray absorptiometry (DXA) in 1000 healthy adults (667 men; 333 women), including fat mass (FM), percent body fat (%BF), fat-free mass (FFM), and visceral adipose tissue (VAT). In subsets, reliability was determined from duplicate MFBIA and DXA obtained within 1 week, and total body water (TBW) was compared to single-frequency BIA (SFBIA).</p><p><strong>Results: </strong>MFBIA demonstrated modest population-level agreement with DXA for total body FM (men, r = 0.93, bias -3.7 ± 2.6 kg; women, r = 0.96, bias, -1.9 ± 1.8 kg), %BF (men, r = 0.89, bias, -4.2 ± 3.0%; women, r = 0.92, bias, -2.8 ± 2.6%), and FFM (men, r = 0.95, bias, 3.4 ± 2.8 kg; women, r = 0.94, bias, 2.0 ± 2.2 kg). Regional correlations were highest for trunk FM (men, r = 0.92, CCC = 0.86; women r = 0.93, CCC = 0.93) and lowest for VAT (men, r = 0.74, CCC = 0.68; women, r = 0.74, CCC = 0.34). DXA and MFBIA regional and total assessments were highly reliable (DXA, ICC 0.990-0.998) and (MFBIA, ICC 0.987-0.995). TBW by MFBIA and SFBIA showed moderate agreement (men, r = 0.73, bias, -1.89 ± 3.31; women, r = 0.82, bias, -1.74 ± 2.01).</p><p><strong>Conclusion: </strong>This MFBIA system was shown to have high retest reliability and, when compared to laboratory methods, provides a moderately accurate method for measuring TBW and body composition (except for VAT) in uncontrolled conditions.</p>","PeriodicalId":11927,"journal":{"name":"European Journal of Clinical Nutrition","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Real-world assessment of Multi-Frequency Bioelectrical Impedance Analysis (MFBIA) for measuring body composition in healthy physically active populations.\",\"authors\":\"Adam W Potter, Leigh C Ward, Christopher L Chapman, William J Tharion, David P Looney, Karl E Friedl\",\"doi\":\"10.1038/s41430-025-01664-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Multi-frequency bioelectrical impedance analysis (MFBIA) methods offer reliable and moderately accurate estimates of body composition in tightly controlled conditions (prandial and hydration status, recent exercise, time of day).</p><p><strong>Objective: </strong>This study examined MFBIA reliability and validity in a real-world environment where these factors were not controlled.</p><p><strong>Methods: </strong>Regional and total body composition estimates by MFBIA (InBody 770) were compared to dual-energy X-ray absorptiometry (DXA) in 1000 healthy adults (667 men; 333 women), including fat mass (FM), percent body fat (%BF), fat-free mass (FFM), and visceral adipose tissue (VAT). In subsets, reliability was determined from duplicate MFBIA and DXA obtained within 1 week, and total body water (TBW) was compared to single-frequency BIA (SFBIA).</p><p><strong>Results: </strong>MFBIA demonstrated modest population-level agreement with DXA for total body FM (men, r = 0.93, bias -3.7 ± 2.6 kg; women, r = 0.96, bias, -1.9 ± 1.8 kg), %BF (men, r = 0.89, bias, -4.2 ± 3.0%; women, r = 0.92, bias, -2.8 ± 2.6%), and FFM (men, r = 0.95, bias, 3.4 ± 2.8 kg; women, r = 0.94, bias, 2.0 ± 2.2 kg). Regional correlations were highest for trunk FM (men, r = 0.92, CCC = 0.86; women r = 0.93, CCC = 0.93) and lowest for VAT (men, r = 0.74, CCC = 0.68; women, r = 0.74, CCC = 0.34). DXA and MFBIA regional and total assessments were highly reliable (DXA, ICC 0.990-0.998) and (MFBIA, ICC 0.987-0.995). TBW by MFBIA and SFBIA showed moderate agreement (men, r = 0.73, bias, -1.89 ± 3.31; women, r = 0.82, bias, -1.74 ± 2.01).</p><p><strong>Conclusion: </strong>This MFBIA system was shown to have high retest reliability and, when compared to laboratory methods, provides a moderately accurate method for measuring TBW and body composition (except for VAT) in uncontrolled conditions.</p>\",\"PeriodicalId\":11927,\"journal\":{\"name\":\"European Journal of Clinical Nutrition\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2025-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Clinical Nutrition\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1038/s41430-025-01664-4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"NUTRITION & DIETETICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Clinical Nutrition","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1038/s41430-025-01664-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NUTRITION & DIETETICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:多频生物电阻抗分析(MFBIA)方法在严格控制的条件下(膳食和水合状态,最近的运动,一天中的时间)提供可靠和中等精度的身体成分估计。目的:本研究在这些因素不受控制的现实环境中检验MFBIA的信度和效度。方法:将1000名健康成人(男性667人,女性333人)的区域和总体身体组成与双能x线吸收仪(DXA)进行比较,包括脂肪量(FM)、体脂百分比(%BF)、无脂量(FFM)和内脏脂肪组织(VAT)。在子集中,通过1周内获得的重复MFBIA和DXA来确定可靠性,并将总体内水分(TBW)与单频BIA (SFBIA)进行比较。结果:MFBIA在总体FM(男性,r = 0.93,偏差-3.7±2.6 kg;女性,r = 0.96,偏差-1.9±1.8 kg)、%BF(男性,r = 0.89,偏差-4.2±3.0%;女性,r = 0.92,偏差-2.8±2.6%)和FFM(男性,r = 0.95,偏差3.4±2.8 kg;女性,r = 0.94,偏差2.0±2.2 kg)方面与DXA在人群水平上表现出适度的一致性。区域相关性最高的是主干FM(男性,r = 0.92, CCC = 0.86;女性r = 0.93, CCC = 0.93),最低的是VAT(男性,r = 0.74, CCC = 0.68;女性,r = 0.74, CCC = 0.34)。DXA和MFBIA区域评价和总评价具有高信度(DXA, ICC 0.990 ~ 0.998), (MFBIA, ICC 0.987 ~ 0.995)。MFBIA和SFBIA的TBW显示中度一致(男性,r = 0.73,偏差,-1.89±3.31;女性,r = 0.82,偏差,-1.74±2.01)。结论:与实验室方法相比,该MFBIA系统具有较高的重测可靠性,可在非受控条件下测量TBW和身体成分(VAT除外)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Real-world assessment of Multi-Frequency Bioelectrical Impedance Analysis (MFBIA) for measuring body composition in healthy physically active populations.

Background: Multi-frequency bioelectrical impedance analysis (MFBIA) methods offer reliable and moderately accurate estimates of body composition in tightly controlled conditions (prandial and hydration status, recent exercise, time of day).

Objective: This study examined MFBIA reliability and validity in a real-world environment where these factors were not controlled.

Methods: Regional and total body composition estimates by MFBIA (InBody 770) were compared to dual-energy X-ray absorptiometry (DXA) in 1000 healthy adults (667 men; 333 women), including fat mass (FM), percent body fat (%BF), fat-free mass (FFM), and visceral adipose tissue (VAT). In subsets, reliability was determined from duplicate MFBIA and DXA obtained within 1 week, and total body water (TBW) was compared to single-frequency BIA (SFBIA).

Results: MFBIA demonstrated modest population-level agreement with DXA for total body FM (men, r = 0.93, bias -3.7 ± 2.6 kg; women, r = 0.96, bias, -1.9 ± 1.8 kg), %BF (men, r = 0.89, bias, -4.2 ± 3.0%; women, r = 0.92, bias, -2.8 ± 2.6%), and FFM (men, r = 0.95, bias, 3.4 ± 2.8 kg; women, r = 0.94, bias, 2.0 ± 2.2 kg). Regional correlations were highest for trunk FM (men, r = 0.92, CCC = 0.86; women r = 0.93, CCC = 0.93) and lowest for VAT (men, r = 0.74, CCC = 0.68; women, r = 0.74, CCC = 0.34). DXA and MFBIA regional and total assessments were highly reliable (DXA, ICC 0.990-0.998) and (MFBIA, ICC 0.987-0.995). TBW by MFBIA and SFBIA showed moderate agreement (men, r = 0.73, bias, -1.89 ± 3.31; women, r = 0.82, bias, -1.74 ± 2.01).

Conclusion: This MFBIA system was shown to have high retest reliability and, when compared to laboratory methods, provides a moderately accurate method for measuring TBW and body composition (except for VAT) in uncontrolled conditions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
10.60
自引率
2.10%
发文量
189
审稿时长
3-6 weeks
期刊介绍: The European Journal of Clinical Nutrition (EJCN) is an international, peer-reviewed journal covering all aspects of human and clinical nutrition. The journal welcomes original research, reviews, case reports and brief communications based on clinical, metabolic and epidemiological studies that describe methodologies, mechanisms, associations and benefits of nutritional interventions for clinical disease and health promotion. Topics of interest include but are not limited to: Nutrition and Health (including climate and ecological aspects) Metabolism & Metabolomics Genomics and personalized strategies in nutrition Nutrition during the early life cycle Health issues and nutrition in the elderly Phenotyping in clinical nutrition Nutrition in acute and chronic diseases The double burden of ''malnutrition'': Under-nutrition and Obesity Prevention of Non Communicable Diseases (NCD)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信