室内空气被动挥发性有机化合物(VOCs)采样器的长期性能研究。

IF 3.7 Q2 ENVIRONMENTAL SCIENCES
Environments - MDPI Pub Date : 2025-08-01 Epub Date: 2025-07-31 DOI:10.3390/environments12080267
John H Zimmerman, Brian Schumacher, Christopher C Lutes, Brian Cosky, Heidi Hayes
{"title":"室内空气被动挥发性有机化合物(VOCs)采样器的长期性能研究。","authors":"John H Zimmerman, Brian Schumacher, Christopher C Lutes, Brian Cosky, Heidi Hayes","doi":"10.3390/environments12080267","DOIUrl":null,"url":null,"abstract":"<p><p>The reliability of passive samplers in measuring volatile organic compounds (VOCs) in indoor air depends on whether the uptake rate is constant given the environmental conditions and sampler exposure duration. The first phase of this study evaluated the performance of charcoal-based, solvent-extracted passive samplers (e.g., Radiello<sup>®</sup> 130 passive samplers with white diffusive bodies) over exposure periods ranging from 1 week to 1 year in a test house with known vapor intrusion (VI). Chloroform %Bias values exceeded the ±30% acceptance criterion after 4 weeks exposure. Benzene, hexane, and trichloroethylene (TCE) concentrations were within the acceptance criterion for up to three months. Toluene and tetrachloroethylene (PCE), the two least volatile compounds, demonstrated uniform uptake rates over one year. In the second phase of this study, testing of the longer exposure times of 6 months and 1 year were evaluated with three additional passive samplers: Waterloo Membrane Sampler<sup>™</sup> (WMS<sup>™</sup>), SKC 575 with secondary diffusive cover, and Radiello<sup>®</sup> 130 passive samplers with yellow diffusive bodies. The SKC 575 and Radiello<sup>®</sup> 130 passive samplers produced acceptable results (%Bias ≤ 30%) over the 6-month exposure period, while the WMS<sup>™</sup> sampler results favored petroleum hydrocarbon more than chlorinated solvent uptake. After the 1-year exposure period, the passive sampler performances were acceptable under specific conditions of this study. The results suggest that all three samplers can produce acceptable results over exposure time periods beyond 30 days and up to a year for some compounds.</p>","PeriodicalId":36821,"journal":{"name":"Environments - MDPI","volume":"12 8","pages":"267"},"PeriodicalIF":3.7000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12425130/pdf/","citationCount":"0","resultStr":"{\"title\":\"Long-Term Performance of Passive Volatile Organic Compounds (VOCs) Samplers for Indoor Air.\",\"authors\":\"John H Zimmerman, Brian Schumacher, Christopher C Lutes, Brian Cosky, Heidi Hayes\",\"doi\":\"10.3390/environments12080267\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The reliability of passive samplers in measuring volatile organic compounds (VOCs) in indoor air depends on whether the uptake rate is constant given the environmental conditions and sampler exposure duration. The first phase of this study evaluated the performance of charcoal-based, solvent-extracted passive samplers (e.g., Radiello<sup>®</sup> 130 passive samplers with white diffusive bodies) over exposure periods ranging from 1 week to 1 year in a test house with known vapor intrusion (VI). Chloroform %Bias values exceeded the ±30% acceptance criterion after 4 weeks exposure. Benzene, hexane, and trichloroethylene (TCE) concentrations were within the acceptance criterion for up to three months. Toluene and tetrachloroethylene (PCE), the two least volatile compounds, demonstrated uniform uptake rates over one year. In the second phase of this study, testing of the longer exposure times of 6 months and 1 year were evaluated with three additional passive samplers: Waterloo Membrane Sampler<sup>™</sup> (WMS<sup>™</sup>), SKC 575 with secondary diffusive cover, and Radiello<sup>®</sup> 130 passive samplers with yellow diffusive bodies. The SKC 575 and Radiello<sup>®</sup> 130 passive samplers produced acceptable results (%Bias ≤ 30%) over the 6-month exposure period, while the WMS<sup>™</sup> sampler results favored petroleum hydrocarbon more than chlorinated solvent uptake. After the 1-year exposure period, the passive sampler performances were acceptable under specific conditions of this study. The results suggest that all three samplers can produce acceptable results over exposure time periods beyond 30 days and up to a year for some compounds.</p>\",\"PeriodicalId\":36821,\"journal\":{\"name\":\"Environments - MDPI\",\"volume\":\"12 8\",\"pages\":\"267\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2025-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12425130/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environments - MDPI\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/environments12080267\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/7/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environments - MDPI","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/environments12080267","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/7/31 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

被动采样器测量室内空气中挥发性有机化合物(VOCs)的可靠性取决于在给定环境条件和采样器暴露时间的情况下吸收率是否恒定。本研究的第一阶段在已知蒸汽侵入(VI)的测试室内,评估了木炭基溶剂萃取被动采样器(例如,Radiello®130白色扩散体被动采样器)在1周到1年的暴露期内的性能。氯仿暴露4周后,偏差值超过±30%可接受标准。苯、己烷和三氯乙烯(TCE)的浓度在长达三个月的可接受标准内。甲苯和四氯乙烯(PCE)这两种挥发性最低的化合物在一年内表现出均匀的吸收率。在本研究的第二阶段,使用另外三种被动采样器评估6个月和1年较长暴露时间的测试:Waterloo Membrane Sampler™(WMS™),带二次扩散盖的SKC 575和带黄色扩散体的Radiello®130被动采样器。SKC 575和Radiello®130被动采样器在6个月的暴露期内产生了可接受的结果(%偏差≤30%),而WMS™采样器的结果更倾向于石油烃而不是氯化溶剂的吸收。经过1年的暴露期,被动采样器的性能在本研究的特定条件下是可以接受的。结果表明,对于某些化合物,所有三种采样器在超过30天甚至长达一年的暴露时间内都能产生可接受的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Long-Term Performance of Passive Volatile Organic Compounds (VOCs) Samplers for Indoor Air.

The reliability of passive samplers in measuring volatile organic compounds (VOCs) in indoor air depends on whether the uptake rate is constant given the environmental conditions and sampler exposure duration. The first phase of this study evaluated the performance of charcoal-based, solvent-extracted passive samplers (e.g., Radiello® 130 passive samplers with white diffusive bodies) over exposure periods ranging from 1 week to 1 year in a test house with known vapor intrusion (VI). Chloroform %Bias values exceeded the ±30% acceptance criterion after 4 weeks exposure. Benzene, hexane, and trichloroethylene (TCE) concentrations were within the acceptance criterion for up to three months. Toluene and tetrachloroethylene (PCE), the two least volatile compounds, demonstrated uniform uptake rates over one year. In the second phase of this study, testing of the longer exposure times of 6 months and 1 year were evaluated with three additional passive samplers: Waterloo Membrane Sampler (WMS), SKC 575 with secondary diffusive cover, and Radiello® 130 passive samplers with yellow diffusive bodies. The SKC 575 and Radiello® 130 passive samplers produced acceptable results (%Bias ≤ 30%) over the 6-month exposure period, while the WMS sampler results favored petroleum hydrocarbon more than chlorinated solvent uptake. After the 1-year exposure period, the passive sampler performances were acceptable under specific conditions of this study. The results suggest that all three samplers can produce acceptable results over exposure time periods beyond 30 days and up to a year for some compounds.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Environments - MDPI
Environments - MDPI Agricultural and Biological Sciences-Ecology, Evolution, Behavior and Systematics
CiteScore
5.70
自引率
5.40%
发文量
135
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信