抛光方法对临时修复体物理性能的影响。

IF 2.4 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Fabio Antonio Piola Rizzante, Zheng Qian, Pedro Henrique Magão, Italo Silva, Guilherme Faria Moura, Gustavo Mendonça
{"title":"抛光方法对临时修复体物理性能的影响。","authors":"Fabio Antonio Piola Rizzante, Zheng Qian, Pedro Henrique Magão, Italo Silva, Guilherme Faria Moura, Gustavo Mendonça","doi":"10.1007/s10266-025-01191-5","DOIUrl":null,"url":null,"abstract":"<p><p>Although surface polishing of temporary restorations is a crucial clinical step, there is a lack of information about the effect of different polishing protocols on the surface properties of 3D printed resins for temporary restorations. This study had as goal to evaluate the effect of different polishing methods on the surface roughness, contact angle, and color stability of temporary restorations. One bis-acrylic resin (Integrity/IT) and 3 resins for 3D printing (Denture teeth, Formlabs/DT, Crown and Bridge MFH, Nextdent/CB, and Cosmos Temp, Yller/CT) were polished following 5 protocols (No polishing/Control, Jiffy Cup/JC, Jiffy Brush/JB, Sof-lex/SL, and Astropol/AS) and tested for surface roughness using a profilometer and for color stability using a spectrophotometer (after immersion in instant coffee for up to 7 days). Data were analyzed using 2-way ANOVA (surface roughness and contact angle) and 3-way repeated measurements ANOVA (color stability), all followed by Tukey test. Overall results of surface roughness showed CT > DT = CB = IT, and Control > JB > AS = SL = JC. The highest surface roughness was observed for IT control group, while the lowest values were observed for CB polished with SL. All groups showed lower surface roughness after being polished with multi-step polishing systems except for CB polished using AS, which showed similar values to CB polished with JB. Overall results of contact angle showed IT > CT > DT > CB, and JC > Control > AS > JB = SL. Highest contact angle was observed for CT control and all resins polished using JC, while the lowest values were observed for CB control group and CT polished using AS. Control groups for IT and CT were more hydrophobic than their respective polished groups, while CB and DT resins were more hydrophobic when polished compared to their respective control groups. Overall results of color variation showed CT > IT = CB > DT, and Control > JB > JC = SL = AS. All tested resins showed color variation higher than the 3.3 clinical threshold when immersed in coffee for 7 days, except DT and CT polished using JC. Different polishing methods can influence the physical properties of different resins used for temporary restorations. All materials showed better results when polished, especially when a multi-step polishing system was used.</p>","PeriodicalId":19390,"journal":{"name":"Odontology","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of polishing methods on the physical properties of temporary restorations.\",\"authors\":\"Fabio Antonio Piola Rizzante, Zheng Qian, Pedro Henrique Magão, Italo Silva, Guilherme Faria Moura, Gustavo Mendonça\",\"doi\":\"10.1007/s10266-025-01191-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Although surface polishing of temporary restorations is a crucial clinical step, there is a lack of information about the effect of different polishing protocols on the surface properties of 3D printed resins for temporary restorations. This study had as goal to evaluate the effect of different polishing methods on the surface roughness, contact angle, and color stability of temporary restorations. One bis-acrylic resin (Integrity/IT) and 3 resins for 3D printing (Denture teeth, Formlabs/DT, Crown and Bridge MFH, Nextdent/CB, and Cosmos Temp, Yller/CT) were polished following 5 protocols (No polishing/Control, Jiffy Cup/JC, Jiffy Brush/JB, Sof-lex/SL, and Astropol/AS) and tested for surface roughness using a profilometer and for color stability using a spectrophotometer (after immersion in instant coffee for up to 7 days). Data were analyzed using 2-way ANOVA (surface roughness and contact angle) and 3-way repeated measurements ANOVA (color stability), all followed by Tukey test. Overall results of surface roughness showed CT > DT = CB = IT, and Control > JB > AS = SL = JC. The highest surface roughness was observed for IT control group, while the lowest values were observed for CB polished with SL. All groups showed lower surface roughness after being polished with multi-step polishing systems except for CB polished using AS, which showed similar values to CB polished with JB. Overall results of contact angle showed IT > CT > DT > CB, and JC > Control > AS > JB = SL. Highest contact angle was observed for CT control and all resins polished using JC, while the lowest values were observed for CB control group and CT polished using AS. Control groups for IT and CT were more hydrophobic than their respective polished groups, while CB and DT resins were more hydrophobic when polished compared to their respective control groups. Overall results of color variation showed CT > IT = CB > DT, and Control > JB > JC = SL = AS. All tested resins showed color variation higher than the 3.3 clinical threshold when immersed in coffee for 7 days, except DT and CT polished using JC. Different polishing methods can influence the physical properties of different resins used for temporary restorations. All materials showed better results when polished, especially when a multi-step polishing system was used.</p>\",\"PeriodicalId\":19390,\"journal\":{\"name\":\"Odontology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2025-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Odontology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10266-025-01191-5\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Odontology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10266-025-01191-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

虽然临时修复体的表面抛光是一个至关重要的临床步骤,但缺乏关于不同抛光方案对临时修复体3D打印树脂表面性能影响的信息。本研究的目的是评估不同抛光方法对临时修复体表面粗糙度、接触角和颜色稳定性的影响。一种双丙烯酸树脂(Integrity/IT)和3种用于3D打印的树脂(Denture teeth, Formlabs/DT, Crown and Bridge MFH, Nextdent/CB, Cosmos Temp, Yller/CT)按照5种方案(No polishing/Control, Jiffy Cup/JC, Jiffy Brush/JB, sofo -lex/SL和Astropol/AS)进行抛光,并使用轮廓仪测试表面粗糙度,使用分光光度计测试颜色稳定性(在速溶咖啡中浸泡长达7天后)。数据分析采用2-way方差分析(表面粗糙度和接触角)和3-way重复测量方差分析(颜色稳定性),并进行Tukey检验。整体表面粗糙度结果显示CT > DT = CB = IT, Control > JB > AS = SL = JC。结果表明,IT组的表面粗糙度最高,而SL抛光的表面粗糙度最低。除AS抛光的CB表面粗糙度与JB抛光的CB表面粗糙度相近外,其余各组表面粗糙度均较低。接触角总体结果为:IT > CT > DT > CB, JC > Control > AS > JB = SL。CT对照组和使用JC抛光的所有树脂接触角最高,而CB对照组和使用AS抛光的CT接触角最低。IT和CT的对照组比各自的抛光组更疏水,而CB和DT树脂在抛光后比各自的对照组更疏水。整体颜色变化结果为CT > IT = CB > DT, Control > JB > JC = SL = AS。除DT和CT用JC抛光外,所有测试树脂在咖啡中浸泡7天后的颜色变化均高于3.3的临床阈值。不同的抛光方法会影响用于临时修复的不同树脂的物理性能。所有材料在抛光后都显示出更好的效果,特别是当使用多步抛光系统时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of polishing methods on the physical properties of temporary restorations.

Although surface polishing of temporary restorations is a crucial clinical step, there is a lack of information about the effect of different polishing protocols on the surface properties of 3D printed resins for temporary restorations. This study had as goal to evaluate the effect of different polishing methods on the surface roughness, contact angle, and color stability of temporary restorations. One bis-acrylic resin (Integrity/IT) and 3 resins for 3D printing (Denture teeth, Formlabs/DT, Crown and Bridge MFH, Nextdent/CB, and Cosmos Temp, Yller/CT) were polished following 5 protocols (No polishing/Control, Jiffy Cup/JC, Jiffy Brush/JB, Sof-lex/SL, and Astropol/AS) and tested for surface roughness using a profilometer and for color stability using a spectrophotometer (after immersion in instant coffee for up to 7 days). Data were analyzed using 2-way ANOVA (surface roughness and contact angle) and 3-way repeated measurements ANOVA (color stability), all followed by Tukey test. Overall results of surface roughness showed CT > DT = CB = IT, and Control > JB > AS = SL = JC. The highest surface roughness was observed for IT control group, while the lowest values were observed for CB polished with SL. All groups showed lower surface roughness after being polished with multi-step polishing systems except for CB polished using AS, which showed similar values to CB polished with JB. Overall results of contact angle showed IT > CT > DT > CB, and JC > Control > AS > JB = SL. Highest contact angle was observed for CT control and all resins polished using JC, while the lowest values were observed for CB control group and CT polished using AS. Control groups for IT and CT were more hydrophobic than their respective polished groups, while CB and DT resins were more hydrophobic when polished compared to their respective control groups. Overall results of color variation showed CT > IT = CB > DT, and Control > JB > JC = SL = AS. All tested resins showed color variation higher than the 3.3 clinical threshold when immersed in coffee for 7 days, except DT and CT polished using JC. Different polishing methods can influence the physical properties of different resins used for temporary restorations. All materials showed better results when polished, especially when a multi-step polishing system was used.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Odontology
Odontology 医学-牙科与口腔外科
CiteScore
5.30
自引率
4.00%
发文量
91
审稿时长
>12 weeks
期刊介绍: The Journal Odontology covers all disciplines involved in the fields of dentistry and craniofacial research, including molecular studies related to oral health and disease. Peer-reviewed articles cover topics ranging from research on human dental pulp, to comparisons of analgesics in surgery, to analysis of biofilm properties of dental plaque.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信