TDCR测量中偶然巧合校正方法的研究

IF 1.8 3区 工程技术 Q3 CHEMISTRY, INORGANIC & NUCLEAR
Karsten Kossert, Marcell Péter Takács
{"title":"TDCR测量中偶然巧合校正方法的研究","authors":"Karsten Kossert,&nbsp;Marcell Péter Takács","doi":"10.1016/j.apradiso.2025.112176","DOIUrl":null,"url":null,"abstract":"<div><div>A recently proposed method from Dutsov et al. (2020) for correcting random coincidences in TDCR measurements was thoroughly examined. To achieve this, an extensive experimental study was conducted using various liquid scintillation (LS) samples. The study involved several radionuclides (<sup>3</sup>H, <sup>32</sup>Si/<sup>32</sup>P, <sup>55</sup>Fe, <sup>89</sup>Sr, <sup>151</sup>Sm, <sup>238</sup>Pu, and <sup>241</sup>Am) as well as background samples. Different LS cocktails and activity levels were also considered. Data acquisition was performed using a fast digitizer, and the resulting list-mode data were analyzed by systematically varying the coincidence resolving time over a range from 10 ns to 1500 ns. All data were evaluated both with and without correction for random coincidences.</div><div>In all cases, the measurement results exhibited significantly better consistency when the correction for random coincidences was applied. This also holds for background measurements. The improvement was particularly evident at longer coincidence resolving times. Moreover, it is demonstrated that the correction is essential for accurately evaluating uncertainties.</div></div>","PeriodicalId":8096,"journal":{"name":"Applied Radiation and Isotopes","volume":"226 ","pages":"Article 112176"},"PeriodicalIF":1.8000,"publicationDate":"2025-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study of a method to correct for accidental coincidences in TDCR measurements\",\"authors\":\"Karsten Kossert,&nbsp;Marcell Péter Takács\",\"doi\":\"10.1016/j.apradiso.2025.112176\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>A recently proposed method from Dutsov et al. (2020) for correcting random coincidences in TDCR measurements was thoroughly examined. To achieve this, an extensive experimental study was conducted using various liquid scintillation (LS) samples. The study involved several radionuclides (<sup>3</sup>H, <sup>32</sup>Si/<sup>32</sup>P, <sup>55</sup>Fe, <sup>89</sup>Sr, <sup>151</sup>Sm, <sup>238</sup>Pu, and <sup>241</sup>Am) as well as background samples. Different LS cocktails and activity levels were also considered. Data acquisition was performed using a fast digitizer, and the resulting list-mode data were analyzed by systematically varying the coincidence resolving time over a range from 10 ns to 1500 ns. All data were evaluated both with and without correction for random coincidences.</div><div>In all cases, the measurement results exhibited significantly better consistency when the correction for random coincidences was applied. This also holds for background measurements. The improvement was particularly evident at longer coincidence resolving times. Moreover, it is demonstrated that the correction is essential for accurately evaluating uncertainties.</div></div>\",\"PeriodicalId\":8096,\"journal\":{\"name\":\"Applied Radiation and Isotopes\",\"volume\":\"226 \",\"pages\":\"Article 112176\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Radiation and Isotopes\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0969804325005214\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Radiation and Isotopes","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0969804325005214","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

摘要

Dutsov等人(2020)最近提出的一种校正TDCR测量随机巧合的方法进行了彻底的检验。为了实现这一点,使用各种液体闪烁(LS)样品进行了广泛的实验研究。该研究涉及几种放射性核素(3H、32Si/32P、55Fe、89Sr、151Sm、238Pu和241Am)以及背景样品。还考虑了不同的LS鸡尾酒和活动水平。使用快速数字化仪进行数据采集,并通过在10 ns到1500 ns的范围内系统地改变符合解析时间来分析得到的列表模式数据。对所有数据进行评估,不论是否对随机巧合进行校正。在所有情况下,当应用随机巧合校正时,测量结果显示出明显更好的一致性。这也适用于背景测量。在较长的巧合解析时间下,这种改善尤为明显。此外,还证明了校正对于准确评估不确定性是必不可少的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study of a method to correct for accidental coincidences in TDCR measurements
A recently proposed method from Dutsov et al. (2020) for correcting random coincidences in TDCR measurements was thoroughly examined. To achieve this, an extensive experimental study was conducted using various liquid scintillation (LS) samples. The study involved several radionuclides (3H, 32Si/32P, 55Fe, 89Sr, 151Sm, 238Pu, and 241Am) as well as background samples. Different LS cocktails and activity levels were also considered. Data acquisition was performed using a fast digitizer, and the resulting list-mode data were analyzed by systematically varying the coincidence resolving time over a range from 10 ns to 1500 ns. All data were evaluated both with and without correction for random coincidences.
In all cases, the measurement results exhibited significantly better consistency when the correction for random coincidences was applied. This also holds for background measurements. The improvement was particularly evident at longer coincidence resolving times. Moreover, it is demonstrated that the correction is essential for accurately evaluating uncertainties.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Radiation and Isotopes
Applied Radiation and Isotopes 工程技术-核科学技术
CiteScore
3.00
自引率
12.50%
发文量
406
审稿时长
13.5 months
期刊介绍: Applied Radiation and Isotopes provides a high quality medium for the publication of substantial, original and scientific and technological papers on the development and peaceful application of nuclear, radiation and radionuclide techniques in chemistry, physics, biochemistry, biology, medicine, security, engineering and in the earth, planetary and environmental sciences, all including dosimetry. Nuclear techniques are defined in the broadest sense and both experimental and theoretical papers are welcome. They include the development and use of α- and β-particles, X-rays and γ-rays, neutrons and other nuclear particles and radiations from all sources, including radionuclides, synchrotron sources, cyclotrons and reactors and from the natural environment. The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria. Papers dealing with radiation processing, i.e., where radiation is used to bring about a biological, chemical or physical change in a material, should be directed to our sister journal Radiation Physics and Chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信