抗菌光动力治疗对牙本质微剪切结合强度的影响。

IF 2.4 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Christian Giancarlo Bernal Rodriguez, Maria Paula Novaes Camargo Manna, Fiorella Elizabeth Arévalo Tarrillo, Carlos de Paula Eduardo
{"title":"抗菌光动力治疗对牙本质微剪切结合强度的影响。","authors":"Christian Giancarlo Bernal Rodriguez, Maria Paula Novaes Camargo Manna, Fiorella Elizabeth Arévalo Tarrillo, Carlos de Paula Eduardo","doi":"10.1007/s10103-025-04602-9","DOIUrl":null,"url":null,"abstract":"<p><p>To evaluate in vitro the bond strength through the micro-shear test of two adhesive systems (self-etching and total-etch), on bovine dentin surfaces after aPDT. For the aPDT, 0.01% methylene blue and two different light sources (red laser and LED) were used.Sixty samples were randomly divided into 6 groups (n = 10) for the micro-shear test: G1: self-etching adhesive (USB) without aPDT, G2: aPDT (laser) + USB, G3: aPDT (LED) + USB; G4: total-etch adhesive (ASB) without aPDT; G5: aPDT (laser) + ASB, G6: aPDT (LED) + ASB), followed by analysis of the fracture patterns of the samples. For statistical analysis, a two-way ANOVA (adhesive and treatment) and Tukey's test were performed, adopting a significance level of 5%.Regarding bond strength, there was no significant difference between the 6 groups analyzed. An adhesive fracture pattern predominated.Based on the results and the irradiation parameters used in this study, no changes in the bond strength of the resin to healthy dentin were observed after treatment with aPDT.</p>","PeriodicalId":17978,"journal":{"name":"Lasers in Medical Science","volume":"40 1","pages":"355"},"PeriodicalIF":2.4000,"publicationDate":"2025-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of antimicrobial photodynamic therapy on micro-shear bond strength to dentin.\",\"authors\":\"Christian Giancarlo Bernal Rodriguez, Maria Paula Novaes Camargo Manna, Fiorella Elizabeth Arévalo Tarrillo, Carlos de Paula Eduardo\",\"doi\":\"10.1007/s10103-025-04602-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>To evaluate in vitro the bond strength through the micro-shear test of two adhesive systems (self-etching and total-etch), on bovine dentin surfaces after aPDT. For the aPDT, 0.01% methylene blue and two different light sources (red laser and LED) were used.Sixty samples were randomly divided into 6 groups (n = 10) for the micro-shear test: G1: self-etching adhesive (USB) without aPDT, G2: aPDT (laser) + USB, G3: aPDT (LED) + USB; G4: total-etch adhesive (ASB) without aPDT; G5: aPDT (laser) + ASB, G6: aPDT (LED) + ASB), followed by analysis of the fracture patterns of the samples. For statistical analysis, a two-way ANOVA (adhesive and treatment) and Tukey's test were performed, adopting a significance level of 5%.Regarding bond strength, there was no significant difference between the 6 groups analyzed. An adhesive fracture pattern predominated.Based on the results and the irradiation parameters used in this study, no changes in the bond strength of the resin to healthy dentin were observed after treatment with aPDT.</p>\",\"PeriodicalId\":17978,\"journal\":{\"name\":\"Lasers in Medical Science\",\"volume\":\"40 1\",\"pages\":\"355\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2025-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lasers in Medical Science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s10103-025-04602-9\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lasers in Medical Science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10103-025-04602-9","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

通过自蚀刻和全蚀刻两种胶粘剂体系在aPDT后牛牙本质表面的微剪切试验,评价其体外粘接强度。对于aPDT,使用0.01%亚甲基蓝和两种不同的光源(红色激光和LED)。60个样品随机分为6组(n = 10)进行微剪切试验:G1:不带aPDT的自蚀刻胶(USB), G2: aPDT(激光)+ USB, G3: aPDT (LED) + USB;G4:不含aPDT的全蚀刻胶(ASB);G5: aPDT(激光)+ ASB, G6: aPDT (LED) + ASB),然后分析样品的断裂模式。统计分析采用双因素方差分析(胶粘剂和处理)和Tukey检验,显著性水平为5%。在粘结强度方面,6组间无显著差异。主要是粘着性骨折。根据本研究的结果和辐照参数,aPDT治疗后树脂与健康牙本质的结合强度没有变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of antimicrobial photodynamic therapy on micro-shear bond strength to dentin.

To evaluate in vitro the bond strength through the micro-shear test of two adhesive systems (self-etching and total-etch), on bovine dentin surfaces after aPDT. For the aPDT, 0.01% methylene blue and two different light sources (red laser and LED) were used.Sixty samples were randomly divided into 6 groups (n = 10) for the micro-shear test: G1: self-etching adhesive (USB) without aPDT, G2: aPDT (laser) + USB, G3: aPDT (LED) + USB; G4: total-etch adhesive (ASB) without aPDT; G5: aPDT (laser) + ASB, G6: aPDT (LED) + ASB), followed by analysis of the fracture patterns of the samples. For statistical analysis, a two-way ANOVA (adhesive and treatment) and Tukey's test were performed, adopting a significance level of 5%.Regarding bond strength, there was no significant difference between the 6 groups analyzed. An adhesive fracture pattern predominated.Based on the results and the irradiation parameters used in this study, no changes in the bond strength of the resin to healthy dentin were observed after treatment with aPDT.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Lasers in Medical Science
Lasers in Medical Science 医学-工程:生物医学
CiteScore
4.50
自引率
4.80%
发文量
192
审稿时长
3-8 weeks
期刊介绍: Lasers in Medical Science (LIMS) has established itself as the leading international journal in the rapidly expanding field of medical and dental applications of lasers and light. It provides a forum for the publication of papers on the technical, experimental, and clinical aspects of the use of medical lasers, including lasers in surgery, endoscopy, angioplasty, hyperthermia of tumors, and photodynamic therapy. In addition to medical laser applications, LIMS presents high-quality manuscripts on a wide range of dental topics, including aesthetic dentistry, endodontics, orthodontics, and prosthodontics. The journal publishes articles on the medical and dental applications of novel laser technologies, light delivery systems, sensors to monitor laser effects, basic laser-tissue interactions, and the modeling of laser-tissue interactions. Beyond laser applications, LIMS features articles relating to the use of non-laser light-tissue interactions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信