Arash Ghaffari, Pernille Damborg Clasen, Andreas Kappel, John Rasmussen, Reed D Gurchiek, Søren Kold, Ole Rahbek
{"title":"使用可穿戴传感器监测全膝关节置换术后的步态恢复:步态加速的反应性。","authors":"Arash Ghaffari, Pernille Damborg Clasen, Andreas Kappel, John Rasmussen, Reed D Gurchiek, Søren Kold, Ole Rahbek","doi":"10.1002/jor.70058","DOIUrl":null,"url":null,"abstract":"<p><p>Functional recovery after total knee arthroplasty (TKA) varies widely among individuals, and traditional assessments often fail to detect subtle changes in real-world walking ability. Wearable sensors offer continuous and objective tracking of gait outside of clinical settings. In this prospective, longitudinal study, thirty-one patients undergoing unilateral TKA wore thigh-mounted accelerometers continuously from 2 weeks before surgery through 90 days postoperatively. We analyzed temporal gait features (stride time and duty factor) and frequency-domain metrics (power of the first five frequencies of triaxial acceleration), along with weekly EQ-5D-3L index scores (a summary measure of health-related quality of life) and visual analog scale (VAS) ratings (patient's self-reported health on a 0-100 scale). Gait acceleration profiles demonstrated significant postoperative disruptions, particularly during mid-stance and terminal swing, followed by gradual normalization, approaching baseline by day 90. Gait temporal parameters also exhibited transient alterations and recovery trends. Using LASSO logistic regression, Fourier-derived gait features discriminated responders and non-responders based on improvements in EQ-5D-3L outcomes above the minimal clinically important difference (AUC: 0.80-0.81). Specific harmonic changes across the vertical, mediolateral, and anteroposterior axes were significantly associated with the perceived health gains. The results indicated that frequency-based gait metrics from wearable sensors are sensitive digital biomarkers for short-term functional improvements.</p>","PeriodicalId":16650,"journal":{"name":"Journal of Orthopaedic Research®","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Monitoring Gait Recovery After Total Knee Arthroplasty Using Wearable Sensors: Responsiveness of Gait Accelerations.\",\"authors\":\"Arash Ghaffari, Pernille Damborg Clasen, Andreas Kappel, John Rasmussen, Reed D Gurchiek, Søren Kold, Ole Rahbek\",\"doi\":\"10.1002/jor.70058\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Functional recovery after total knee arthroplasty (TKA) varies widely among individuals, and traditional assessments often fail to detect subtle changes in real-world walking ability. Wearable sensors offer continuous and objective tracking of gait outside of clinical settings. In this prospective, longitudinal study, thirty-one patients undergoing unilateral TKA wore thigh-mounted accelerometers continuously from 2 weeks before surgery through 90 days postoperatively. We analyzed temporal gait features (stride time and duty factor) and frequency-domain metrics (power of the first five frequencies of triaxial acceleration), along with weekly EQ-5D-3L index scores (a summary measure of health-related quality of life) and visual analog scale (VAS) ratings (patient's self-reported health on a 0-100 scale). Gait acceleration profiles demonstrated significant postoperative disruptions, particularly during mid-stance and terminal swing, followed by gradual normalization, approaching baseline by day 90. Gait temporal parameters also exhibited transient alterations and recovery trends. Using LASSO logistic regression, Fourier-derived gait features discriminated responders and non-responders based on improvements in EQ-5D-3L outcomes above the minimal clinically important difference (AUC: 0.80-0.81). Specific harmonic changes across the vertical, mediolateral, and anteroposterior axes were significantly associated with the perceived health gains. The results indicated that frequency-based gait metrics from wearable sensors are sensitive digital biomarkers for short-term functional improvements.</p>\",\"PeriodicalId\":16650,\"journal\":{\"name\":\"Journal of Orthopaedic Research®\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Research®\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jor.70058\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Research®","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jor.70058","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Monitoring Gait Recovery After Total Knee Arthroplasty Using Wearable Sensors: Responsiveness of Gait Accelerations.
Functional recovery after total knee arthroplasty (TKA) varies widely among individuals, and traditional assessments often fail to detect subtle changes in real-world walking ability. Wearable sensors offer continuous and objective tracking of gait outside of clinical settings. In this prospective, longitudinal study, thirty-one patients undergoing unilateral TKA wore thigh-mounted accelerometers continuously from 2 weeks before surgery through 90 days postoperatively. We analyzed temporal gait features (stride time and duty factor) and frequency-domain metrics (power of the first five frequencies of triaxial acceleration), along with weekly EQ-5D-3L index scores (a summary measure of health-related quality of life) and visual analog scale (VAS) ratings (patient's self-reported health on a 0-100 scale). Gait acceleration profiles demonstrated significant postoperative disruptions, particularly during mid-stance and terminal swing, followed by gradual normalization, approaching baseline by day 90. Gait temporal parameters also exhibited transient alterations and recovery trends. Using LASSO logistic regression, Fourier-derived gait features discriminated responders and non-responders based on improvements in EQ-5D-3L outcomes above the minimal clinically important difference (AUC: 0.80-0.81). Specific harmonic changes across the vertical, mediolateral, and anteroposterior axes were significantly associated with the perceived health gains. The results indicated that frequency-based gait metrics from wearable sensors are sensitive digital biomarkers for short-term functional improvements.
期刊介绍:
The Journal of Orthopaedic Research is the forum for the rapid publication of high quality reports of new information on the full spectrum of orthopaedic research, including life sciences, engineering, translational, and clinical studies.