一种新型非球面疏水丙烯酸环形人工晶状体的袋内行为。

IF 3 3区 医学 Q1 OPHTHALMOLOGY
Nikolaus Mahnert, Marcus Lisy, Victor Danzinger, Markus Schranz, Claudette Abela-Formanek, Rupert Menapace, Christina Leydolt, Daniel Schartmüller
{"title":"一种新型非球面疏水丙烯酸环形人工晶状体的袋内行为。","authors":"Nikolaus Mahnert, Marcus Lisy, Victor Danzinger, Markus Schranz, Claudette Abela-Formanek, Rupert Menapace, Christina Leydolt, Daniel Schartmüller","doi":"10.3928/1081597X-20250624-04","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate tilt, decentration, and axial stability of the Clareon toric intraocular lens (TIOL) (CNW0T3-9; Alcon Laboratories, Inc) over a 6-month follow-up period.</p><p><strong>Methods: </strong>A single-center, prospective, interventional clinical trial was conducted with a study population of 130 eyes from 82 patients who received a Clareon TIOL. Tilt, decentration, and the aqueous depth were determined preoperatively and at 1 week and 6 months postoperatively using anterior segment optical coherence tomography (Casia 2; Tomey Corporation). Difference vectors were used to assess changes in individual decentration and tilt. Uncorrected intermediate visual acuity was measured at 66 cm at 6 months postoperatively.</p><p><strong>Results: </strong>Mean tilt and decentration values were 5.7 ± 1.7° and 0.17 ± 0.1 mm for the crystalline lens, 5.6 ± 1.5° and 0.24 ± 0.13 mm for the TIOL at 1 week, and 5.8° ± 1.6° and 0.24 ± 0.15 mm for the TIOL at 6 months. Mean changes in tilt and decentration from preoperatively to 6 months were 1.01 ± 0.86° and 0.18 ± 0.12 mm. Tilt and decentration correlated between the crystalline lens and TIOL at 6 months (<i>r</i> = 0.92; <i>P</i> < .01, <i>r</i> = 0.29; <i>P</i> < .01). A posterior axial shift of 0.023 ± 0.054 mm was observed between 1 week and 6 months. Mean binocular uncorrected intermediate visual acuity at 66 cm at 6 months postoperatively was 0.18 ± 0.13 logarithm of the minimum angle of resolution (20/30 Snellen).</p><p><strong>Conclusions: </strong>Tilt and decentration of the Clareon TIOL were generally low and a strong correlation was found between crystalline lens tilt and TIOL tilt at 6 months.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"41 9","pages":"e906-e916"},"PeriodicalIF":3.0000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In-the-Bag Behavior of a New Aspheric Hydrophobic Acrylic Toric Intraocular Lens.\",\"authors\":\"Nikolaus Mahnert, Marcus Lisy, Victor Danzinger, Markus Schranz, Claudette Abela-Formanek, Rupert Menapace, Christina Leydolt, Daniel Schartmüller\",\"doi\":\"10.3928/1081597X-20250624-04\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate tilt, decentration, and axial stability of the Clareon toric intraocular lens (TIOL) (CNW0T3-9; Alcon Laboratories, Inc) over a 6-month follow-up period.</p><p><strong>Methods: </strong>A single-center, prospective, interventional clinical trial was conducted with a study population of 130 eyes from 82 patients who received a Clareon TIOL. Tilt, decentration, and the aqueous depth were determined preoperatively and at 1 week and 6 months postoperatively using anterior segment optical coherence tomography (Casia 2; Tomey Corporation). Difference vectors were used to assess changes in individual decentration and tilt. Uncorrected intermediate visual acuity was measured at 66 cm at 6 months postoperatively.</p><p><strong>Results: </strong>Mean tilt and decentration values were 5.7 ± 1.7° and 0.17 ± 0.1 mm for the crystalline lens, 5.6 ± 1.5° and 0.24 ± 0.13 mm for the TIOL at 1 week, and 5.8° ± 1.6° and 0.24 ± 0.15 mm for the TIOL at 6 months. Mean changes in tilt and decentration from preoperatively to 6 months were 1.01 ± 0.86° and 0.18 ± 0.12 mm. Tilt and decentration correlated between the crystalline lens and TIOL at 6 months (<i>r</i> = 0.92; <i>P</i> < .01, <i>r</i> = 0.29; <i>P</i> < .01). A posterior axial shift of 0.023 ± 0.054 mm was observed between 1 week and 6 months. Mean binocular uncorrected intermediate visual acuity at 66 cm at 6 months postoperatively was 0.18 ± 0.13 logarithm of the minimum angle of resolution (20/30 Snellen).</p><p><strong>Conclusions: </strong>Tilt and decentration of the Clareon TIOL were generally low and a strong correlation was found between crystalline lens tilt and TIOL tilt at 6 months.</p>\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":\"41 9\",\"pages\":\"e906-e916\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597X-20250624-04\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20250624-04","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估Clareon环形人工晶状体(TIOL) (CNW0T3-9; Alcon Laboratories, Inc)在6个月的随访期间的倾斜、分散和轴向稳定性。方法:采用一项单中心、前瞻性、介入性临床试验,研究人群为82例接受Clareon TIOL的患者,共130只眼。术前、术后1周和6个月采用前段光学相干断层扫描(Casia 2; Tomey Corporation)测定倾斜、分散和水深。差异向量用于评估个体分散和倾斜的变化。术后6个月测量未矫正的中间视力为66 cm。结果:晶状体的平均倾斜和偏心值为5.7±1.7°和0.17±0.1 mm, 1周时TIOL的平均倾斜和偏心值为5.6±1.5°和0.24±0.13 mm, 6个月时TIOL的平均倾斜和偏心值为5.8°±1.6°和0.24±0.15 mm。术前至6个月的平均倾斜和偏位变化分别为1.01±0.86°和0.18±0.12 mm。6个月时晶状体倾斜和离体与TIOL相关(r = 0.92, P < 0.01, r = 0.29, P < 0.01)。术后1周至6个月后轴向移位0.023±0.054 mm。术后6个月66 cm处双眼未矫正中间视力平均值为最小分辨角(20/30 Snellen)的0.18±0.13对数。结论:Clareon TIOL的倾斜度和分散度普遍较低,6个月时晶状体倾斜度与TIOL倾斜度有很强的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In-the-Bag Behavior of a New Aspheric Hydrophobic Acrylic Toric Intraocular Lens.

Purpose: To evaluate tilt, decentration, and axial stability of the Clareon toric intraocular lens (TIOL) (CNW0T3-9; Alcon Laboratories, Inc) over a 6-month follow-up period.

Methods: A single-center, prospective, interventional clinical trial was conducted with a study population of 130 eyes from 82 patients who received a Clareon TIOL. Tilt, decentration, and the aqueous depth were determined preoperatively and at 1 week and 6 months postoperatively using anterior segment optical coherence tomography (Casia 2; Tomey Corporation). Difference vectors were used to assess changes in individual decentration and tilt. Uncorrected intermediate visual acuity was measured at 66 cm at 6 months postoperatively.

Results: Mean tilt and decentration values were 5.7 ± 1.7° and 0.17 ± 0.1 mm for the crystalline lens, 5.6 ± 1.5° and 0.24 ± 0.13 mm for the TIOL at 1 week, and 5.8° ± 1.6° and 0.24 ± 0.15 mm for the TIOL at 6 months. Mean changes in tilt and decentration from preoperatively to 6 months were 1.01 ± 0.86° and 0.18 ± 0.12 mm. Tilt and decentration correlated between the crystalline lens and TIOL at 6 months (r = 0.92; P < .01, r = 0.29; P < .01). A posterior axial shift of 0.023 ± 0.054 mm was observed between 1 week and 6 months. Mean binocular uncorrected intermediate visual acuity at 66 cm at 6 months postoperatively was 0.18 ± 0.13 logarithm of the minimum angle of resolution (20/30 Snellen).

Conclusions: Tilt and decentration of the Clareon TIOL were generally low and a strong correlation was found between crystalline lens tilt and TIOL tilt at 6 months.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信