智能手机脉搏血氧仪用于客观牙髓活力评估的临床验证:一项诊断准确性研究。

IF 3.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Celso Luiz Caldeira, Stephanie Isabel Diaz Zamalloa, Claudia Regina Guimaro Sakitani, Fernando Branco Barletta, Marinella Holzhausen
{"title":"智能手机脉搏血氧仪用于客观牙髓活力评估的临床验证:一项诊断准确性研究。","authors":"Celso Luiz Caldeira, Stephanie Isabel Diaz Zamalloa, Claudia Regina Guimaro Sakitani, Fernando Branco Barletta, Marinella Holzhausen","doi":"10.1016/j.joen.2025.09.003","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Pulse oximetry exhibits great potential for use in endodontic diagnosis as an effective method to assess pulp vitality. Cell phone-integrated oximeters represent an emerging alternative that may offer greater accessibility. This study aimed to investigate the relation between pulp oxygenation rates (%SpO<sub>2</sub>) and clinical diagnosis of healthy pulp (HP), reversible pulpitis (RP), symptomatic irreversible pulpitis (IP), or pulp necrosis (PN), comparing 2 pulse oximeters (conventional [PO1] and mobile-connected).</p><p><strong>Methods: </strong>Thirty affected premolars were grouped according to the clinical diagnosis of RP, IP, or PN and compared to vitality diagnosis by %SpO<sub>2</sub> obtained by both pulse oximeters: PO1 and by smartphone-based (PO2). For each affected tooth, 2 additional teeth (adjacent and contralateral) with HP were tested. Statistical analysis was performed using one-way ANOVA with Tukey's post-hoc test.</p><p><strong>Results: </strong>The mean %SpO<sub>2</sub> values measured by PO1 were 87.7% for RP, 80.5% for IP, 73.2% for PN, and 91.89% for HP. Corresponding values obtained with PO2 were 85.6% (RP), 79.3% (IP), 72.1% (PN), and 90.1% (HP). Significant differences in %SpO<sub>2</sub> were observed among RP, IP, and PN groups (P < .05), but not between healthy control subgroups (adjacent and contralateral). PO1 consistently recorded higher oxygen saturation than PO2 across all clinical conditions (P < .05), demonstrating superior discriminatory capability.</p><p><strong>Conclusions: </strong>Both pulse oximeters demonstrated significant clinical value for pulp vitality assessment and differentiation of pulpal inflammation stages and necrosis. The smartphone-adapted oximeter has proven to be comparable to PO1 in diagnostic performance, while offering data collection efficiency and clinical workflow integration.</p>","PeriodicalId":15703,"journal":{"name":"Journal of endodontics","volume":" ","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2025-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical Validation of Smartphone-Enabled Pulse Oximetry for Objective Pulp Vitality Assessment: A Diagnostic Accuracy Study.\",\"authors\":\"Celso Luiz Caldeira, Stephanie Isabel Diaz Zamalloa, Claudia Regina Guimaro Sakitani, Fernando Branco Barletta, Marinella Holzhausen\",\"doi\":\"10.1016/j.joen.2025.09.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Pulse oximetry exhibits great potential for use in endodontic diagnosis as an effective method to assess pulp vitality. Cell phone-integrated oximeters represent an emerging alternative that may offer greater accessibility. This study aimed to investigate the relation between pulp oxygenation rates (%SpO<sub>2</sub>) and clinical diagnosis of healthy pulp (HP), reversible pulpitis (RP), symptomatic irreversible pulpitis (IP), or pulp necrosis (PN), comparing 2 pulse oximeters (conventional [PO1] and mobile-connected).</p><p><strong>Methods: </strong>Thirty affected premolars were grouped according to the clinical diagnosis of RP, IP, or PN and compared to vitality diagnosis by %SpO<sub>2</sub> obtained by both pulse oximeters: PO1 and by smartphone-based (PO2). For each affected tooth, 2 additional teeth (adjacent and contralateral) with HP were tested. Statistical analysis was performed using one-way ANOVA with Tukey's post-hoc test.</p><p><strong>Results: </strong>The mean %SpO<sub>2</sub> values measured by PO1 were 87.7% for RP, 80.5% for IP, 73.2% for PN, and 91.89% for HP. Corresponding values obtained with PO2 were 85.6% (RP), 79.3% (IP), 72.1% (PN), and 90.1% (HP). Significant differences in %SpO<sub>2</sub> were observed among RP, IP, and PN groups (P < .05), but not between healthy control subgroups (adjacent and contralateral). PO1 consistently recorded higher oxygen saturation than PO2 across all clinical conditions (P < .05), demonstrating superior discriminatory capability.</p><p><strong>Conclusions: </strong>Both pulse oximeters demonstrated significant clinical value for pulp vitality assessment and differentiation of pulpal inflammation stages and necrosis. The smartphone-adapted oximeter has proven to be comparable to PO1 in diagnostic performance, while offering data collection efficiency and clinical workflow integration.</p>\",\"PeriodicalId\":15703,\"journal\":{\"name\":\"Journal of endodontics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2025-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of endodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.joen.2025.09.003\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of endodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.joen.2025.09.003","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

简介:脉搏血氧仪作为评估牙髓活力的有效方法,在牙髓诊断中显示出巨大的潜力。手机集成血氧仪代表了一种新兴的替代方案,可能提供更大的可及性。本研究旨在探讨牙髓氧合率(%SpO2)与健康牙髓(HP)、可逆性牙髓炎(RP)、症状性不可逆性牙髓炎(IP)或牙髓坏死(PN)临床诊断的关系,并比较两种脉搏血氧仪(常规和移动连接)。方法:将30例患前磨牙根据RP、IP或PN的临床诊断进行分组,并与常规脉搏血氧仪(PO1)和智能手机脉搏血氧仪(PO2)测得的%SpO2对活力的诊断进行比较。对于每一个受影响的牙齿,另外两个牙齿(相邻(A)和对侧(C))进行HP检测。统计学分析采用单因素方差分析和Tukey事后检验。结果:PO1测定的平均%SpO2值RP为87.7%,IP为80.5%,PN为73.2%,HP为91.89%。PO2分别为85.6% (RP)、79.3% (IP)、72.1% (PN)和90.1% (HP)。结论:两种脉搏血氧仪对牙髓活力评估和牙髓炎症分期及坏死的鉴别具有重要的临床价值。这款适用于智能手机的血氧仪已被证明在诊断性能上与传统血氧仪相当,同时提供数据收集效率和临床工作流程集成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Clinical Validation of Smartphone-Enabled Pulse Oximetry for Objective Pulp Vitality Assessment: A Diagnostic Accuracy Study.

Introduction: Pulse oximetry exhibits great potential for use in endodontic diagnosis as an effective method to assess pulp vitality. Cell phone-integrated oximeters represent an emerging alternative that may offer greater accessibility. This study aimed to investigate the relation between pulp oxygenation rates (%SpO2) and clinical diagnosis of healthy pulp (HP), reversible pulpitis (RP), symptomatic irreversible pulpitis (IP), or pulp necrosis (PN), comparing 2 pulse oximeters (conventional [PO1] and mobile-connected).

Methods: Thirty affected premolars were grouped according to the clinical diagnosis of RP, IP, or PN and compared to vitality diagnosis by %SpO2 obtained by both pulse oximeters: PO1 and by smartphone-based (PO2). For each affected tooth, 2 additional teeth (adjacent and contralateral) with HP were tested. Statistical analysis was performed using one-way ANOVA with Tukey's post-hoc test.

Results: The mean %SpO2 values measured by PO1 were 87.7% for RP, 80.5% for IP, 73.2% for PN, and 91.89% for HP. Corresponding values obtained with PO2 were 85.6% (RP), 79.3% (IP), 72.1% (PN), and 90.1% (HP). Significant differences in %SpO2 were observed among RP, IP, and PN groups (P < .05), but not between healthy control subgroups (adjacent and contralateral). PO1 consistently recorded higher oxygen saturation than PO2 across all clinical conditions (P < .05), demonstrating superior discriminatory capability.

Conclusions: Both pulse oximeters demonstrated significant clinical value for pulp vitality assessment and differentiation of pulpal inflammation stages and necrosis. The smartphone-adapted oximeter has proven to be comparable to PO1 in diagnostic performance, while offering data collection efficiency and clinical workflow integration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of endodontics
Journal of endodontics 医学-牙科与口腔外科
CiteScore
8.80
自引率
9.50%
发文量
224
审稿时长
42 days
期刊介绍: The Journal of Endodontics, the official journal of the American Association of Endodontists, publishes scientific articles, case reports and comparison studies evaluating materials and methods of pulp conservation and endodontic treatment. Endodontists and general dentists can learn about new concepts in root canal treatment and the latest advances in techniques and instrumentation in the one journal that helps them keep pace with rapid changes in this field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信