Evan P. Bailey MD , Bryce T. Hrudka BS , Bailey J. Ross MD , Ajay Premkumar MD, MPH , Jacob M. Wilson MD , Galen E. Berdis MD
{"title":"初次全髋关节置换术中双活动聚乙烯衬垫骨折:现代设计的新并发症:1例报告","authors":"Evan P. Bailey MD , Bryce T. Hrudka BS , Bailey J. Ross MD , Ajay Premkumar MD, MPH , Jacob M. Wilson MD , Galen E. Berdis MD","doi":"10.1016/j.artd.2025.101800","DOIUrl":null,"url":null,"abstract":"<div><div>We present the first documented case of polyethylene liner fracture in a primary dual-mobility cup (DMC) total hip arthroplasty leading to intraprosthetic dislocation. A 50-year-old female with a history of hip dysplasia and leg length discrepancy underwent primary total hip arthroplasty with a DMC. She presented with an anterior intraprosthetic hip dislocation. Revision surgery revealed a fractured highly cross-linked polyethylene liner. The liner and fragments were removed and a new liner was implanted. This case underscores the potential mechanical limitations of highly cross-linked polyethylene in DMC configurations.</div></div>","PeriodicalId":37940,"journal":{"name":"Arthroplasty Today","volume":"35 ","pages":"Article 101800"},"PeriodicalIF":2.1000,"publicationDate":"2025-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fracture of Dual-Mobility Polyethylene Liner in a Primary Total Hip Arthroplasty: A New Complication to a Modern Design: A Case Report\",\"authors\":\"Evan P. Bailey MD , Bryce T. Hrudka BS , Bailey J. Ross MD , Ajay Premkumar MD, MPH , Jacob M. Wilson MD , Galen E. Berdis MD\",\"doi\":\"10.1016/j.artd.2025.101800\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>We present the first documented case of polyethylene liner fracture in a primary dual-mobility cup (DMC) total hip arthroplasty leading to intraprosthetic dislocation. A 50-year-old female with a history of hip dysplasia and leg length discrepancy underwent primary total hip arthroplasty with a DMC. She presented with an anterior intraprosthetic hip dislocation. Revision surgery revealed a fractured highly cross-linked polyethylene liner. The liner and fragments were removed and a new liner was implanted. This case underscores the potential mechanical limitations of highly cross-linked polyethylene in DMC configurations.</div></div>\",\"PeriodicalId\":37940,\"journal\":{\"name\":\"Arthroplasty Today\",\"volume\":\"35 \",\"pages\":\"Article 101800\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-09-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arthroplasty Today\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352344125001876\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroplasty Today","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352344125001876","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Fracture of Dual-Mobility Polyethylene Liner in a Primary Total Hip Arthroplasty: A New Complication to a Modern Design: A Case Report
We present the first documented case of polyethylene liner fracture in a primary dual-mobility cup (DMC) total hip arthroplasty leading to intraprosthetic dislocation. A 50-year-old female with a history of hip dysplasia and leg length discrepancy underwent primary total hip arthroplasty with a DMC. She presented with an anterior intraprosthetic hip dislocation. Revision surgery revealed a fractured highly cross-linked polyethylene liner. The liner and fragments were removed and a new liner was implanted. This case underscores the potential mechanical limitations of highly cross-linked polyethylene in DMC configurations.
期刊介绍:
Arthroplasty Today is a companion journal to the Journal of Arthroplasty. The journal Arthroplasty Today brings together the clinical and scientific foundations for joint replacement of the hip and knee in an open-access, online format. Arthroplasty Today solicits manuscripts of the highest quality from all areas of scientific endeavor that relate to joint replacement or the treatment of its complications, including those dealing with patient outcomes, economic and policy issues, prosthetic design, biomechanics, biomaterials, and biologic response to arthroplasty. The journal focuses on case reports. It is the purpose of Arthroplasty Today to present material to practicing orthopaedic surgeons that will keep them abreast of developments in the field, prove useful in the care of patients, and aid in understanding the scientific foundation of this subspecialty area of joint replacement. The international members of the Editorial Board provide a worldwide perspective for the journal''s area of interest. Their participation ensures that each issue of Arthroplasty Today provides the reader with timely, peer-reviewed articles of the highest quality.