“Feelfit®”加速度计评估儿童身体活动和久坐时间的效度和信度:两种不同加速度计的比较研究。

Q1 Health Professions
International journal of exercise science Pub Date : 2025-09-01 eCollection Date: 2025-01-01 DOI:10.70252/NOCK5583
Songdhasn Chinapong, Korntawat Klinchan, Hanif Abdul Rahman, Michael Chia, Waris Wongpipit, Jetsada Arnin, Areekul Amornsriwatanakul
{"title":"“Feelfit®”加速度计评估儿童身体活动和久坐时间的效度和信度:两种不同加速度计的比较研究。","authors":"Songdhasn Chinapong, Korntawat Klinchan, Hanif Abdul Rahman, Michael Chia, Waris Wongpipit, Jetsada Arnin, Areekul Amornsriwatanakul","doi":"10.70252/NOCK5583","DOIUrl":null,"url":null,"abstract":"<p><p>Accurate physical activity (PA) measurement is crucial for public health surveillance. While self-report questionnaires are commonly used, they have limitations, especially in young children. An affordable and user-friendly device like Feelfit® offers a promising alternative particularly for countries with limited research resources. This study aimed to evaluate Feelfit®'s performance against the widely used ActiGraph® accelerometer in measuring PA among children. A quasi-experimental design was applied. Thirty-nine children (19 boys; 20 girls; aged 11.4 ± 0.5 years) wore both Feelfit® and ActiGraph® during sequentially specified activities of varying intensity ranging from sedentary to vigorous. Data were analysed using paired t-tests, Bland-Altman plots, and intra-class correlation coefficients (ICCs) to assess agreement, precision, and reliability. Feelfit® showed good agreement with ActiGraph® for moderate-to-vigorous PA (MVPA) but overestimated sedentary time and underestimated light PA. It demonstrated better precision for MVPA but low reliability for light PA. Intra-class correlation coefficients were moderate for MVPA (ICC = 0.43), but poor for sedentary time (ICC = 0.11). Feelfit® is a suitable option for measuring MVPA in children, offering acceptable validity and reliability compared to ActiGraph®. However, improvements are needed for accurate measure of sedentary and light activities. Despite these limitations, Feelfit®'s affordability and ease of use make it a valuable tool for use in small- to large-scale research and in resource-limited settings.</p>","PeriodicalId":14171,"journal":{"name":"International journal of exercise science","volume":"18 2","pages":"794-810"},"PeriodicalIF":0.0000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12408083/pdf/","citationCount":"0","resultStr":"{\"title\":\"Validity and Reliability of the 'Feelfit®' Accelerometer in Evaluating Physical Activity and Sedentary Time in Children: A Comparative Study with Two Different Accelerometers.\",\"authors\":\"Songdhasn Chinapong, Korntawat Klinchan, Hanif Abdul Rahman, Michael Chia, Waris Wongpipit, Jetsada Arnin, Areekul Amornsriwatanakul\",\"doi\":\"10.70252/NOCK5583\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Accurate physical activity (PA) measurement is crucial for public health surveillance. While self-report questionnaires are commonly used, they have limitations, especially in young children. An affordable and user-friendly device like Feelfit® offers a promising alternative particularly for countries with limited research resources. This study aimed to evaluate Feelfit®'s performance against the widely used ActiGraph® accelerometer in measuring PA among children. A quasi-experimental design was applied. Thirty-nine children (19 boys; 20 girls; aged 11.4 ± 0.5 years) wore both Feelfit® and ActiGraph® during sequentially specified activities of varying intensity ranging from sedentary to vigorous. Data were analysed using paired t-tests, Bland-Altman plots, and intra-class correlation coefficients (ICCs) to assess agreement, precision, and reliability. Feelfit® showed good agreement with ActiGraph® for moderate-to-vigorous PA (MVPA) but overestimated sedentary time and underestimated light PA. It demonstrated better precision for MVPA but low reliability for light PA. Intra-class correlation coefficients were moderate for MVPA (ICC = 0.43), but poor for sedentary time (ICC = 0.11). Feelfit® is a suitable option for measuring MVPA in children, offering acceptable validity and reliability compared to ActiGraph®. However, improvements are needed for accurate measure of sedentary and light activities. Despite these limitations, Feelfit®'s affordability and ease of use make it a valuable tool for use in small- to large-scale research and in resource-limited settings.</p>\",\"PeriodicalId\":14171,\"journal\":{\"name\":\"International journal of exercise science\",\"volume\":\"18 2\",\"pages\":\"794-810\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12408083/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of exercise science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.70252/NOCK5583\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of exercise science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.70252/NOCK5583","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

摘要

准确的身体活动(PA)测量对公共卫生监测至关重要。虽然自我报告问卷是常用的,但它们有局限性,特别是在幼儿中。像Feelfit®这样价格合理且用户友好的设备为研究资源有限的国家提供了一个有希望的替代方案。本研究旨在评估Feelfit®与广泛使用的ActiGraph®加速度计在测量儿童PA方面的表现。采用准实验设计。39名儿童(19名男孩,20名女孩,年龄11.4±0.5岁)分别穿着Feelfit®和ActiGraph®进行从久坐到剧烈运动等不同强度的活动。采用配对t检验、Bland-Altman图和类内相关系数(ICCs)对数据进行分析,以评估一致性、精确性和可靠性。Feelfit®与ActiGraph®在中度至剧烈PA (MVPA)方面表现出良好的一致性,但高估了久坐时间,低估了轻度PA。该方法对MVPA精度较高,但对轻型PA可靠性较低。MVPA的类内相关系数中等(ICC = 0.43),但久坐时间的类内相关系数较低(ICC = 0.11)。Feelfit®是测量儿童MVPA的合适选择,与ActiGraph®相比,提供可接受的效度和可靠性。然而,对于久坐和轻度活动的精确测量还需要改进。尽管存在这些限制,Feelfit®的可负担性和易用性使其成为小型到大规模研究和资源有限环境中使用的有价值的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Validity and Reliability of the 'Feelfit®' Accelerometer in Evaluating Physical Activity and Sedentary Time in Children: A Comparative Study with Two Different Accelerometers.

Validity and Reliability of the 'Feelfit®' Accelerometer in Evaluating Physical Activity and Sedentary Time in Children: A Comparative Study with Two Different Accelerometers.

Validity and Reliability of the 'Feelfit®' Accelerometer in Evaluating Physical Activity and Sedentary Time in Children: A Comparative Study with Two Different Accelerometers.

Accurate physical activity (PA) measurement is crucial for public health surveillance. While self-report questionnaires are commonly used, they have limitations, especially in young children. An affordable and user-friendly device like Feelfit® offers a promising alternative particularly for countries with limited research resources. This study aimed to evaluate Feelfit®'s performance against the widely used ActiGraph® accelerometer in measuring PA among children. A quasi-experimental design was applied. Thirty-nine children (19 boys; 20 girls; aged 11.4 ± 0.5 years) wore both Feelfit® and ActiGraph® during sequentially specified activities of varying intensity ranging from sedentary to vigorous. Data were analysed using paired t-tests, Bland-Altman plots, and intra-class correlation coefficients (ICCs) to assess agreement, precision, and reliability. Feelfit® showed good agreement with ActiGraph® for moderate-to-vigorous PA (MVPA) but overestimated sedentary time and underestimated light PA. It demonstrated better precision for MVPA but low reliability for light PA. Intra-class correlation coefficients were moderate for MVPA (ICC = 0.43), but poor for sedentary time (ICC = 0.11). Feelfit® is a suitable option for measuring MVPA in children, offering acceptable validity and reliability compared to ActiGraph®. However, improvements are needed for accurate measure of sedentary and light activities. Despite these limitations, Feelfit®'s affordability and ease of use make it a valuable tool for use in small- to large-scale research and in resource-limited settings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International journal of exercise science
International journal of exercise science Health Professions-Occupational Therapy
CiteScore
2.20
自引率
0.00%
发文量
47
审稿时长
26 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信