{"title":"单焦点人工晶体、增强单焦点人工晶体和扩大聚焦深度人工晶体离焦曲线的meta分析。","authors":"Sathish Srinivasan, Cyril Nyankerh, Jessie Hull, Rajaraman Suryakumar","doi":"10.1136/bmjophth-2024-002025","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aims: </strong>Recently, modified monofocal intraocular lenses (IOLs) (proposed mono plus IOLs) have emerged claiming to provide monofocal quality distance vision while enhancing intermediate distance visual performance. The purpose of this study was to conduct a literature review and compare the range of vision following cataract surgery with the implantation of standard monofocal, claimed monofocal plus and extended depth of focus (EDoF) IOLs.</p><p><strong>Methods: </strong>Literature searches and a meta-analysis were conducted on Embase, PubMed, IOLEvidence App and the Food and Drug Administration premarket approval database. Mean defocus curves were calculated with a random effect model and study quality was assessed.</p><p><strong>Results: </strong>After eliminating duplicate publications, 36 studies were included in the data extraction process. Standard monofocal IOLs were implanted in 549 eyes, 360 eyes with claimed mono plus IOLs and 1898 eyes with EDoF IOLs. At far viewing acuity, the performance of all three lens categories appeared comparable: all p>0.05. However, at the intermediate distance of 66 cm (-1.5D), and at a near distance of 40 cm (-2.50D), monofocal and mono plus defocus curve acuities exhibited comparable performance: p=0.22 and 0.77 respectively, while EDoF lenses demonstrated better acuity (all p<0.05).</p><p><strong>Conclusions: </strong>There is a lack of standardisation of defocus curve measurements among published papers included in this meta-analysis. Despite some slight inconsistencies in measurements, the range of vision of standard monofocal IOLs and mono plus IOLs as measured by the defocus curve appears to be similar. The EDoF IOLs in this meta-analysis indicate a potentially better range of vision compared with mono plus and monofocal IOLs.</p><p><strong>Synopsis: </strong>This meta-analysis seems to indicate that EDoF IOLs may have a better range of vision as measured by defocus curves compared with mono plus and monofocal IOLs.</p>","PeriodicalId":9286,"journal":{"name":"BMJ Open Ophthalmology","volume":"10 1","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12410659/pdf/","citationCount":"0","resultStr":"{\"title\":\"Meta-analysis of defocus curves of monofocal, enhanced monofocal and extended depth of focus IOLs.\",\"authors\":\"Sathish Srinivasan, Cyril Nyankerh, Jessie Hull, Rajaraman Suryakumar\",\"doi\":\"10.1136/bmjophth-2024-002025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/aims: </strong>Recently, modified monofocal intraocular lenses (IOLs) (proposed mono plus IOLs) have emerged claiming to provide monofocal quality distance vision while enhancing intermediate distance visual performance. The purpose of this study was to conduct a literature review and compare the range of vision following cataract surgery with the implantation of standard monofocal, claimed monofocal plus and extended depth of focus (EDoF) IOLs.</p><p><strong>Methods: </strong>Literature searches and a meta-analysis were conducted on Embase, PubMed, IOLEvidence App and the Food and Drug Administration premarket approval database. Mean defocus curves were calculated with a random effect model and study quality was assessed.</p><p><strong>Results: </strong>After eliminating duplicate publications, 36 studies were included in the data extraction process. Standard monofocal IOLs were implanted in 549 eyes, 360 eyes with claimed mono plus IOLs and 1898 eyes with EDoF IOLs. At far viewing acuity, the performance of all three lens categories appeared comparable: all p>0.05. However, at the intermediate distance of 66 cm (-1.5D), and at a near distance of 40 cm (-2.50D), monofocal and mono plus defocus curve acuities exhibited comparable performance: p=0.22 and 0.77 respectively, while EDoF lenses demonstrated better acuity (all p<0.05).</p><p><strong>Conclusions: </strong>There is a lack of standardisation of defocus curve measurements among published papers included in this meta-analysis. Despite some slight inconsistencies in measurements, the range of vision of standard monofocal IOLs and mono plus IOLs as measured by the defocus curve appears to be similar. The EDoF IOLs in this meta-analysis indicate a potentially better range of vision compared with mono plus and monofocal IOLs.</p><p><strong>Synopsis: </strong>This meta-analysis seems to indicate that EDoF IOLs may have a better range of vision as measured by defocus curves compared with mono plus and monofocal IOLs.</p>\",\"PeriodicalId\":9286,\"journal\":{\"name\":\"BMJ Open Ophthalmology\",\"volume\":\"10 1\",\"pages\":\"\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12410659/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMJ Open Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1136/bmjophth-2024-002025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Open Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjophth-2024-002025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
背景/目的:最近,改良的单焦点人工晶状体(iol)(提议的mono + iol)已经出现,声称在提高中距离视觉性能的同时提供单焦点质量的远距离视觉。本研究的目的是进行文献综述,并比较白内障手术后的视力范围与标准单焦点、单焦点加扩展焦深(EDoF)人工晶体植入术后的视力范围。方法:在Embase、PubMed、IOLEvidence App和美国食品药品监督管理局上市前批准数据库中进行文献检索和meta分析。采用随机效应模型计算平均离焦曲线,并评价研究质量。结果:排除重复发表后,36篇研究纳入数据提取过程。标准单焦点人工晶状体549眼,单眼+人工晶状体360眼,EDoF人工晶状体1898眼。在远视锐度上,三种晶状体的性能均具有可比性:均p < 0.05。然而,在66 cm (-1.5D)的中间距离和40 cm (-2.50D)的近距离下,单焦和单加离焦曲线的清晰度表现相当,分别为p=0.22和0.77,而EDoF透镜的清晰度更好(均为p)。结论:本meta分析纳入的已发表论文对离焦曲线的测量缺乏标准化。尽管测量结果略有不一致,但通过离焦曲线测量的标准单焦点iol和单焦点+ iol的视力范围似乎相似。在这项荟萃分析中,EDoF人工晶状体与单眼+和单焦点人工晶状体相比,具有更好的潜在视力范围。摘要:这项荟萃分析似乎表明,EDoF人工晶状体与单眼+和单眼人工晶状体相比,通过离焦曲线测量的视力范围可能更好。
Meta-analysis of defocus curves of monofocal, enhanced monofocal and extended depth of focus IOLs.
Background/aims: Recently, modified monofocal intraocular lenses (IOLs) (proposed mono plus IOLs) have emerged claiming to provide monofocal quality distance vision while enhancing intermediate distance visual performance. The purpose of this study was to conduct a literature review and compare the range of vision following cataract surgery with the implantation of standard monofocal, claimed monofocal plus and extended depth of focus (EDoF) IOLs.
Methods: Literature searches and a meta-analysis were conducted on Embase, PubMed, IOLEvidence App and the Food and Drug Administration premarket approval database. Mean defocus curves were calculated with a random effect model and study quality was assessed.
Results: After eliminating duplicate publications, 36 studies were included in the data extraction process. Standard monofocal IOLs were implanted in 549 eyes, 360 eyes with claimed mono plus IOLs and 1898 eyes with EDoF IOLs. At far viewing acuity, the performance of all three lens categories appeared comparable: all p>0.05. However, at the intermediate distance of 66 cm (-1.5D), and at a near distance of 40 cm (-2.50D), monofocal and mono plus defocus curve acuities exhibited comparable performance: p=0.22 and 0.77 respectively, while EDoF lenses demonstrated better acuity (all p<0.05).
Conclusions: There is a lack of standardisation of defocus curve measurements among published papers included in this meta-analysis. Despite some slight inconsistencies in measurements, the range of vision of standard monofocal IOLs and mono plus IOLs as measured by the defocus curve appears to be similar. The EDoF IOLs in this meta-analysis indicate a potentially better range of vision compared with mono plus and monofocal IOLs.
Synopsis: This meta-analysis seems to indicate that EDoF IOLs may have a better range of vision as measured by defocus curves compared with mono plus and monofocal IOLs.