{"title":"动脉瘤性胸升主动脉患者特异性模型的可信度评估:验证、验证和不确定度量化。","authors":"Roberta Scuoppo, Chiara Catalano, Fabrizio Crascì, Salvatore Pasta","doi":"10.1007/s13239-025-00801-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Computational modeling holds promise in predicting patient-specific outcomes and guiding clinical decision-making. The patient-specific model forming the basis of a digital twin can be considered biomedical software, thereby necessitating trust in its predictive accuracy.</p><p><strong>Methods: </strong>This study applies the ASME V&V40 framework to demonstrate the credibility of patient-specific models of aneurysmal thoracic ascending aorta (ATAA) biomechanics. A comprehensive verification, validation, and uncertainty quantification process was performed to evaluate the accuracy of the patient-specific ATAA model.</p><p><strong>Results: </strong>After implementing the ASME V&V40 standard, the verification errors on the model inputs (i.e., material parameters and hemodynamic variables) resulted in relative errors (RE) < 1%. Validation and its uncertainty quantification of the output aneurysm diameter response showed area metric errors below 5% in the majority of cases, highlighting the accuracy of the patient-specific ATAA model against the clinical comparator. Uncertainties in wall stress predictions due to model inputs were also quantified by probability density functions. Sensitivity analysis revealed that the unknown value of aneurysm wall thickness drives the model output at the highest extent.</p><p><strong>Conclusions: </strong>These findings contribute to a standardized methodology for evaluating the credibility of patient-specific models, enhancing their utility in computer-based clinical decision support systems for managing patients with ATAAs.</p>","PeriodicalId":54322,"journal":{"name":"Cardiovascular Engineering and Technology","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Credibility Assessment of the Patient-Specific Modeling of the Aneurysmal Ascending Thoracic Aorta: Verification, Validation and Uncertainty Quantification.\",\"authors\":\"Roberta Scuoppo, Chiara Catalano, Fabrizio Crascì, Salvatore Pasta\",\"doi\":\"10.1007/s13239-025-00801-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Computational modeling holds promise in predicting patient-specific outcomes and guiding clinical decision-making. The patient-specific model forming the basis of a digital twin can be considered biomedical software, thereby necessitating trust in its predictive accuracy.</p><p><strong>Methods: </strong>This study applies the ASME V&V40 framework to demonstrate the credibility of patient-specific models of aneurysmal thoracic ascending aorta (ATAA) biomechanics. A comprehensive verification, validation, and uncertainty quantification process was performed to evaluate the accuracy of the patient-specific ATAA model.</p><p><strong>Results: </strong>After implementing the ASME V&V40 standard, the verification errors on the model inputs (i.e., material parameters and hemodynamic variables) resulted in relative errors (RE) < 1%. Validation and its uncertainty quantification of the output aneurysm diameter response showed area metric errors below 5% in the majority of cases, highlighting the accuracy of the patient-specific ATAA model against the clinical comparator. Uncertainties in wall stress predictions due to model inputs were also quantified by probability density functions. Sensitivity analysis revealed that the unknown value of aneurysm wall thickness drives the model output at the highest extent.</p><p><strong>Conclusions: </strong>These findings contribute to a standardized methodology for evaluating the credibility of patient-specific models, enhancing their utility in computer-based clinical decision support systems for managing patients with ATAAs.</p>\",\"PeriodicalId\":54322,\"journal\":{\"name\":\"Cardiovascular Engineering and Technology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-08-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Engineering and Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s13239-025-00801-1\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Engineering and Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s13239-025-00801-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

目的:计算模型在预测患者特异性结果和指导临床决策方面具有前景。形成数字孪生基础的患者特定模型可以被视为生物医学软件,因此需要信任其预测准确性。方法:本研究应用ASME V&V40框架来验证患者特异性动脉瘤性胸升主动脉(ATAA)生物力学模型的可信度。进行全面的验证、验证和不确定度量化过程来评估患者特异性ATAA模型的准确性。结果:在实施ASME V&V40标准后,模型输入(即材料参数和血流动力学变量)的验证错误导致了相对误差(RE)。结论:这些发现有助于评估患者特异性模型可信度的标准化方法,增强其在管理ATAAs患者的基于计算机的临床决策支持系统中的实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Credibility Assessment of the Patient-Specific Modeling of the Aneurysmal Ascending Thoracic Aorta: Verification, Validation and Uncertainty Quantification.

Purpose: Computational modeling holds promise in predicting patient-specific outcomes and guiding clinical decision-making. The patient-specific model forming the basis of a digital twin can be considered biomedical software, thereby necessitating trust in its predictive accuracy.

Methods: This study applies the ASME V&V40 framework to demonstrate the credibility of patient-specific models of aneurysmal thoracic ascending aorta (ATAA) biomechanics. A comprehensive verification, validation, and uncertainty quantification process was performed to evaluate the accuracy of the patient-specific ATAA model.

Results: After implementing the ASME V&V40 standard, the verification errors on the model inputs (i.e., material parameters and hemodynamic variables) resulted in relative errors (RE) < 1%. Validation and its uncertainty quantification of the output aneurysm diameter response showed area metric errors below 5% in the majority of cases, highlighting the accuracy of the patient-specific ATAA model against the clinical comparator. Uncertainties in wall stress predictions due to model inputs were also quantified by probability density functions. Sensitivity analysis revealed that the unknown value of aneurysm wall thickness drives the model output at the highest extent.

Conclusions: These findings contribute to a standardized methodology for evaluating the credibility of patient-specific models, enhancing their utility in computer-based clinical decision support systems for managing patients with ATAAs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cardiovascular Engineering and Technology
Cardiovascular Engineering and Technology Engineering-Biomedical Engineering
CiteScore
4.00
自引率
0.00%
发文量
51
期刊介绍: Cardiovascular Engineering and Technology is a journal publishing the spectrum of basic to translational research in all aspects of cardiovascular physiology and medical treatment. It is the forum for academic and industrial investigators to disseminate research that utilizes engineering principles and methods to advance fundamental knowledge and technological solutions related to the cardiovascular system. Manuscripts spanning from subcellular to systems level topics are invited, including but not limited to implantable medical devices, hemodynamics and tissue biomechanics, functional imaging, surgical devices, electrophysiology, tissue engineering and regenerative medicine, diagnostic instruments, transport and delivery of biologics, and sensors. In addition to manuscripts describing the original publication of research, manuscripts reviewing developments in these topics or their state-of-art are also invited.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信