基于M1-M2分叉角的M2闭塞取栓技术研究。

IF 2.1 4区 医学 Q4 CLINICAL NEUROLOGY
Koji Shimonaga, Hirotoshi Imamura, Junichiro Ochiai, Akihiro Niwa, Yuji Kushi, Taichi Ikedo, Eika Hamano, Tomohide Yoshie, Kiyofumi Yamada, Hisae Mori, Masatoshi Koga, Kazunori Toyoda, Masafumi Ihara, Koji Iihara, Hiroharu Kataoka
{"title":"基于M1-M2分叉角的M2闭塞取栓技术研究。","authors":"Koji Shimonaga, Hirotoshi Imamura, Junichiro Ochiai, Akihiro Niwa, Yuji Kushi, Taichi Ikedo, Eika Hamano, Tomohide Yoshie, Kiyofumi Yamada, Hisae Mori, Masatoshi Koga, Kazunori Toyoda, Masafumi Ihara, Koji Iihara, Hiroharu Kataoka","doi":"10.1177/15910199251367546","DOIUrl":null,"url":null,"abstract":"<p><p>PurposeThe efficacy of mechanical thrombectomy (MT) for M2 occlusion remains uncertain, partly due to recanalization challenges owing to anatomical factors and hemorrhagic complications. This study investigated the best method for M2 occlusion based on the M1-M2 bifurcation angle.MethodsWe retrospectively evaluated the clinical data of 134 consecutive patients with M2 occlusion who underwent MT. The M1-M2 angle was measured between the conterminous (M2) and immediately proximal (M1) vessel segments with respect to the occlusion site. Patients were divided into the acute- and obtuse-angle groups. For each angle, we investigated the stent retriever (SR), contact aspiration (CA), and combined technique (CT) of MT.ResultsThere were 64 and 70 obtuse- and acute-angle cases, respectively. Univariate analysis showed no significant difference in the M1-M2 angle between the groups, but there was a trend toward increased intracranial hemorrhage in the obtuse-angle group (56% vs. 41%, <i>p</i> = 0.09). CA was significantly associated with lower postoperative subarachnoid hemorrhage incidence in the obtuse-angle group (CA vs. SR vs. CT: 9% vs. 39% vs. 50%, <i>p</i> = 0.02). In the acute-angle group, CT was significantly superior in number of passes (CT vs. SR vs. CA: 1.4 vs. 1.8 vs. 2.4, <i>p</i> = 0.03), puncture-recanalization time (48.5 vs. 59.1 vs. 69.4, <i>p</i> = 0.04), and modified first-pass effect (mFPE; 67% vs. 48% vs. 21%, <i>p</i> = 0.01). No association was observed between the first-line technique and clinical outcomes for any angle.ConclusionProcedure results varied according to the M1-M2 bifurcation angle. For treating M2 occlusion, the bifurcation angle should be considered in the choice of technique.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"15910199251367546"},"PeriodicalIF":2.1000,"publicationDate":"2025-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12394206/pdf/","citationCount":"0","resultStr":"{\"title\":\"Investigation of thrombectomy technique for M2 occlusion based on the M1-M2 bifurcation angle.\",\"authors\":\"Koji Shimonaga, Hirotoshi Imamura, Junichiro Ochiai, Akihiro Niwa, Yuji Kushi, Taichi Ikedo, Eika Hamano, Tomohide Yoshie, Kiyofumi Yamada, Hisae Mori, Masatoshi Koga, Kazunori Toyoda, Masafumi Ihara, Koji Iihara, Hiroharu Kataoka\",\"doi\":\"10.1177/15910199251367546\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>PurposeThe efficacy of mechanical thrombectomy (MT) for M2 occlusion remains uncertain, partly due to recanalization challenges owing to anatomical factors and hemorrhagic complications. This study investigated the best method for M2 occlusion based on the M1-M2 bifurcation angle.MethodsWe retrospectively evaluated the clinical data of 134 consecutive patients with M2 occlusion who underwent MT. The M1-M2 angle was measured between the conterminous (M2) and immediately proximal (M1) vessel segments with respect to the occlusion site. Patients were divided into the acute- and obtuse-angle groups. For each angle, we investigated the stent retriever (SR), contact aspiration (CA), and combined technique (CT) of MT.ResultsThere were 64 and 70 obtuse- and acute-angle cases, respectively. Univariate analysis showed no significant difference in the M1-M2 angle between the groups, but there was a trend toward increased intracranial hemorrhage in the obtuse-angle group (56% vs. 41%, <i>p</i> = 0.09). CA was significantly associated with lower postoperative subarachnoid hemorrhage incidence in the obtuse-angle group (CA vs. SR vs. CT: 9% vs. 39% vs. 50%, <i>p</i> = 0.02). In the acute-angle group, CT was significantly superior in number of passes (CT vs. SR vs. CA: 1.4 vs. 1.8 vs. 2.4, <i>p</i> = 0.03), puncture-recanalization time (48.5 vs. 59.1 vs. 69.4, <i>p</i> = 0.04), and modified first-pass effect (mFPE; 67% vs. 48% vs. 21%, <i>p</i> = 0.01). No association was observed between the first-line technique and clinical outcomes for any angle.ConclusionProcedure results varied according to the M1-M2 bifurcation angle. For treating M2 occlusion, the bifurcation angle should be considered in the choice of technique.</p>\",\"PeriodicalId\":49174,\"journal\":{\"name\":\"Interventional Neuroradiology\",\"volume\":\" \",\"pages\":\"15910199251367546\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-08-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12394206/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Neuroradiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15910199251367546\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199251367546","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的机械取栓(MT)治疗M2闭塞的疗效尚不确定,部分原因是解剖学因素和出血并发症导致再通困难。本研究基于M1-M2分叉角,探讨最佳的M2遮挡方法。方法回顾性分析134例连续行MT治疗的M2闭塞患者的临床资料,测量闭塞部位邻近血管段(M2)和近端血管段(M1)之间的M1-M2角。将患者分为锐角组和钝角组。对于每个角度,我们分别研究了支架回收器(SR)、接触吸吸器(CA)和mt联合技术(CT)。结果钝角和锐角分别有64例和70例。单因素分析显示,两组间M1-M2角度差异无统计学意义,但钝角组颅内出血有增加的趋势(56%比41%,p = 0.09)。在钝角组,CA与术后较低的蛛网膜下腔出血发生率显著相关(CA vs SR vs CT: 9% vs 39% vs 50%, p = 0.02)。在急性角度组,CT在通过次数(CT vs SR vs CA: 1.4次vs 1.8次vs 2.4次,p = 0.03)、穿刺再通时间(48.5次vs 59.1次vs 69.4次,p = 0.04)和改良的首次通过效果(mFPE: 67% vs 48% vs 21%, p = 0.01)上均显著优于SR组。没有观察到一线技术与任何角度的临床结果之间的关联。结论不同M1-M2分岔角度手术效果不同。对于治疗M2闭塞,在技术选择上应考虑分叉角度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of thrombectomy technique for M2 occlusion based on the M1-M2 bifurcation angle.

PurposeThe efficacy of mechanical thrombectomy (MT) for M2 occlusion remains uncertain, partly due to recanalization challenges owing to anatomical factors and hemorrhagic complications. This study investigated the best method for M2 occlusion based on the M1-M2 bifurcation angle.MethodsWe retrospectively evaluated the clinical data of 134 consecutive patients with M2 occlusion who underwent MT. The M1-M2 angle was measured between the conterminous (M2) and immediately proximal (M1) vessel segments with respect to the occlusion site. Patients were divided into the acute- and obtuse-angle groups. For each angle, we investigated the stent retriever (SR), contact aspiration (CA), and combined technique (CT) of MT.ResultsThere were 64 and 70 obtuse- and acute-angle cases, respectively. Univariate analysis showed no significant difference in the M1-M2 angle between the groups, but there was a trend toward increased intracranial hemorrhage in the obtuse-angle group (56% vs. 41%, p = 0.09). CA was significantly associated with lower postoperative subarachnoid hemorrhage incidence in the obtuse-angle group (CA vs. SR vs. CT: 9% vs. 39% vs. 50%, p = 0.02). In the acute-angle group, CT was significantly superior in number of passes (CT vs. SR vs. CA: 1.4 vs. 1.8 vs. 2.4, p = 0.03), puncture-recanalization time (48.5 vs. 59.1 vs. 69.4, p = 0.04), and modified first-pass effect (mFPE; 67% vs. 48% vs. 21%, p = 0.01). No association was observed between the first-line technique and clinical outcomes for any angle.ConclusionProcedure results varied according to the M1-M2 bifurcation angle. For treating M2 occlusion, the bifurcation angle should be considered in the choice of technique.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Interventional Neuroradiology
Interventional Neuroradiology CLINICAL NEUROLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
3.60
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信