压模材料的厚度是否会影响添加硅酮压模和最终铸件的精度?三维分析。

IF 1.2 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
E E Negm, M Patel, P Ryan
{"title":"压模材料的厚度是否会影响添加硅酮压模和最终铸件的精度?三维分析。","authors":"E E Negm, M Patel, P Ryan","doi":"10.1922/EJPRD_2795Negm17","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Conflicting evidence exists regarding the optimal impression thickness and the influence of tray spacing on the accuracy of elastomeric impressions and resulting casts. This study evaluated the effect of three tray spacings (2 mm, 4 mm, and 6 mm) on the dimensional accuracy of three addition silicone impression materials (Aquasil, Panasil, and Elite-HD).</p><p><strong>Methods: </strong>Forty-five impressions of a partially dentate maxillary resin cast were made using standardized custom trays with designated spacer thicknesses. Impressions were scanned using a desktop scanner, and casts were poured into type IV dental stone and subsequently scanned. A digital reference cast was generated and used to superimpose all test scans. Deviations were measured across the full arch, palate, and dentulous-edentulous (horseshoe) regions using digital metrology software. Data were analyzed using multiple regression and Tukey HSD post-hoc tests (α = 0.05).</p><p><strong>Results: </strong>Spacer thickness and material significantly influenced impression and cast accuracy, with higher deviations observed in the horseshoe region compared to the palate (p ⟨ 0.001).</p><p><strong>Conclusions: </strong>Panasil at 6-mm spacing produced the most accurate impressions across all regions.</p><p><strong>Clinical relevance: </strong>For cast accuracy, Elite-HD at 4-mm spacing showed the lowest deviation in the palate, while Panasil at 2-mm spacing demonstrated superior accuracy in both full arch and horseshoe regions.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2025-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Does Impression Material Thickness Impact the Accuracy of Addition Silicone Impressions and the Resultant Casts? A 3D Analysis.\",\"authors\":\"E E Negm, M Patel, P Ryan\",\"doi\":\"10.1922/EJPRD_2795Negm17\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Conflicting evidence exists regarding the optimal impression thickness and the influence of tray spacing on the accuracy of elastomeric impressions and resulting casts. This study evaluated the effect of three tray spacings (2 mm, 4 mm, and 6 mm) on the dimensional accuracy of three addition silicone impression materials (Aquasil, Panasil, and Elite-HD).</p><p><strong>Methods: </strong>Forty-five impressions of a partially dentate maxillary resin cast were made using standardized custom trays with designated spacer thicknesses. Impressions were scanned using a desktop scanner, and casts were poured into type IV dental stone and subsequently scanned. A digital reference cast was generated and used to superimpose all test scans. Deviations were measured across the full arch, palate, and dentulous-edentulous (horseshoe) regions using digital metrology software. Data were analyzed using multiple regression and Tukey HSD post-hoc tests (α = 0.05).</p><p><strong>Results: </strong>Spacer thickness and material significantly influenced impression and cast accuracy, with higher deviations observed in the horseshoe region compared to the palate (p ⟨ 0.001).</p><p><strong>Conclusions: </strong>Panasil at 6-mm spacing produced the most accurate impressions across all regions.</p><p><strong>Clinical relevance: </strong>For cast accuracy, Elite-HD at 4-mm spacing showed the lowest deviation in the palate, while Panasil at 2-mm spacing demonstrated superior accuracy in both full arch and horseshoe regions.</p>\",\"PeriodicalId\":45686,\"journal\":{\"name\":\"European Journal of Prosthodontics and Restorative Dentistry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2025-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Prosthodontics and Restorative Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1922/EJPRD_2795Negm17\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Prosthodontics and Restorative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1922/EJPRD_2795Negm17","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:关于最佳压痕厚度和托盘间距对弹性体压痕和最终铸件精度的影响存在矛盾的证据。本研究评估了三种托盘间距(2mm, 4mm和6mm)对三种添加硅胶印模材料(Aquasil, Panasil和Elite-HD)尺寸精度的影响。方法:采用指定间隔厚度的标准定制托盘制作45个部分齿状上颌树脂铸型印模。使用桌面扫描仪扫描印模,并将铸型倒入IV型牙石中,随后进行扫描。生成一个数字参考铸型,并用于叠加所有测试扫描。使用数字测量软件测量全弓、上颚和假牙-无牙(马蹄)区域的偏差。采用多元回归和Tukey HSD事后检验对数据进行分析(α = 0.05)。结果:垫片厚度和材料显著影响印模和铸造精度,与上颚相比,马蹄区观察到更高的偏差(p⟨0.001)。结论:6毫米间距的Panasil在所有区域产生最准确的印象。临床相关性:对于铸型精度,间距为4mm的Elite-HD在上颚的偏差最小,而间距为2mm的Panasil在全弓和马蹄区都表现出更高的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Does Impression Material Thickness Impact the Accuracy of Addition Silicone Impressions and the Resultant Casts? A 3D Analysis.

Objectives: Conflicting evidence exists regarding the optimal impression thickness and the influence of tray spacing on the accuracy of elastomeric impressions and resulting casts. This study evaluated the effect of three tray spacings (2 mm, 4 mm, and 6 mm) on the dimensional accuracy of three addition silicone impression materials (Aquasil, Panasil, and Elite-HD).

Methods: Forty-five impressions of a partially dentate maxillary resin cast were made using standardized custom trays with designated spacer thicknesses. Impressions were scanned using a desktop scanner, and casts were poured into type IV dental stone and subsequently scanned. A digital reference cast was generated and used to superimpose all test scans. Deviations were measured across the full arch, palate, and dentulous-edentulous (horseshoe) regions using digital metrology software. Data were analyzed using multiple regression and Tukey HSD post-hoc tests (α = 0.05).

Results: Spacer thickness and material significantly influenced impression and cast accuracy, with higher deviations observed in the horseshoe region compared to the palate (p ⟨ 0.001).

Conclusions: Panasil at 6-mm spacing produced the most accurate impressions across all regions.

Clinical relevance: For cast accuracy, Elite-HD at 4-mm spacing showed the lowest deviation in the palate, while Panasil at 2-mm spacing demonstrated superior accuracy in both full arch and horseshoe regions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
7.70%
发文量
0
期刊介绍: The European Journal of Prosthodontics and Restorative Dentistry is published quarterly and includes clinical and research articles in subjects such as prosthodontics, operative dentistry, implantology, endodontics, periodontics and dental materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信