仅用柱凝集技术检测抗sda特异性的复方新恶唑依赖自体凝集素。

IF 0.6 Q4 HEMATOLOGY
Asian Journal of Transfusion Science Pub Date : 2025-01-01 Epub Date: 2025-06-30 DOI:10.4103/ajts.ajts_112_24
Revathy K Nair, Akshay Batra, Mayuri Vekariya, Priya Radadiya, Sanmukh Ratilal Joshi
{"title":"仅用柱凝集技术检测抗sda特异性的复方新恶唑依赖自体凝集素。","authors":"Revathy K Nair, Akshay Batra, Mayuri Vekariya, Priya Radadiya, Sanmukh Ratilal Joshi","doi":"10.4103/ajts.ajts_112_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong><i>In vitro</i> serological reactions due to antibodies in the presence of certain chemicals are rare occurrences. Although such antibodies are often considered harmless, their innocuous nature requires verification. We investigated a pan-agglutinating antibody that reacted in the presence of BLISS used in the gel card device.</p><p><strong>Materials and methods: </strong>The gel cards used for serological compatibility tests were of commercial sources (Ortho Diagnostics, USA and Tulip Diagnostics, India), soluble antigens used for antibody neutralization tests were locally obtained, and certain antibiotics and dialysis bags were procured from the local market. Serological workup was carried out by standard methods.</p><p><strong>Results: </strong>A 13-year-old female cancer patient with a pan-reacting autoantibody showed mixed-field agglutination in serological tests. It reacted only on a gel card system that uses BLISS-containing antibiotic co-trimoxazole. Autoantibody was identified as anti-Sd<sup>a</sup> by hemagglutination inhibition test using guinea pig urine.</p><p><strong>Conclusion: </strong>The autoantibody with anti-Sd<sup>a</sup> specificity was detected on the gel card only in the presence of the antibiotic co-trimoxazole in BLISS.</p>","PeriodicalId":42296,"journal":{"name":"Asian Journal of Transfusion Science","volume":"19 1","pages":"1-5"},"PeriodicalIF":0.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12364041/pdf/","citationCount":"0","resultStr":"{\"title\":\"Co-trimoxazole-dependent autoagglutinin with anti-Sd<sup>a</sup> specificity detected only by column agglutination technique.\",\"authors\":\"Revathy K Nair, Akshay Batra, Mayuri Vekariya, Priya Radadiya, Sanmukh Ratilal Joshi\",\"doi\":\"10.4103/ajts.ajts_112_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objectives: </strong><i>In vitro</i> serological reactions due to antibodies in the presence of certain chemicals are rare occurrences. Although such antibodies are often considered harmless, their innocuous nature requires verification. We investigated a pan-agglutinating antibody that reacted in the presence of BLISS used in the gel card device.</p><p><strong>Materials and methods: </strong>The gel cards used for serological compatibility tests were of commercial sources (Ortho Diagnostics, USA and Tulip Diagnostics, India), soluble antigens used for antibody neutralization tests were locally obtained, and certain antibiotics and dialysis bags were procured from the local market. Serological workup was carried out by standard methods.</p><p><strong>Results: </strong>A 13-year-old female cancer patient with a pan-reacting autoantibody showed mixed-field agglutination in serological tests. It reacted only on a gel card system that uses BLISS-containing antibiotic co-trimoxazole. Autoantibody was identified as anti-Sd<sup>a</sup> by hemagglutination inhibition test using guinea pig urine.</p><p><strong>Conclusion: </strong>The autoantibody with anti-Sd<sup>a</sup> specificity was detected on the gel card only in the presence of the antibiotic co-trimoxazole in BLISS.</p>\",\"PeriodicalId\":42296,\"journal\":{\"name\":\"Asian Journal of Transfusion Science\",\"volume\":\"19 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12364041/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Transfusion Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ajts.ajts_112_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/6/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Transfusion Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ajts.ajts_112_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/30 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:在某些化学物质存在的情况下,由抗体引起的体外血清学反应很少发生。虽然这些抗体通常被认为是无害的,但它们的无害性质需要验证。我们研究了一种泛凝集抗体,该抗体在凝胶卡装置中使用BLISS存在时发生反应。材料和方法:用于血清学相容性试验的凝胶卡来自商业来源(美国Ortho诊断公司和印度Tulip诊断公司),用于抗体中和试验的可溶性抗原在当地获得,某些抗生素和透析袋从当地市场采购。血清学检查按标准方法进行。结果:一名13岁的女性癌症患者,其泛反应性自身抗体在血清学测试中显示混合场凝集。它只在一个凝胶卡系统上反应,该系统使用了含有bliss的抗生素复方新诺明。用豚鼠尿液进行血凝抑制试验,鉴定自身抗体为抗sda抗体。结论:BLISS仅在抗生素复方新诺明存在的情况下,在凝胶卡上检测到具有抗sda特异性的自身抗体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Co-trimoxazole-dependent autoagglutinin with anti-Sd<sup>a</sup> specificity detected only by column agglutination technique.

Co-trimoxazole-dependent autoagglutinin with anti-Sd<sup>a</sup> specificity detected only by column agglutination technique.

Co-trimoxazole-dependent autoagglutinin with anti-Sd<sup>a</sup> specificity detected only by column agglutination technique.

Co-trimoxazole-dependent autoagglutinin with anti-Sda specificity detected only by column agglutination technique.

Background and objectives: In vitro serological reactions due to antibodies in the presence of certain chemicals are rare occurrences. Although such antibodies are often considered harmless, their innocuous nature requires verification. We investigated a pan-agglutinating antibody that reacted in the presence of BLISS used in the gel card device.

Materials and methods: The gel cards used for serological compatibility tests were of commercial sources (Ortho Diagnostics, USA and Tulip Diagnostics, India), soluble antigens used for antibody neutralization tests were locally obtained, and certain antibiotics and dialysis bags were procured from the local market. Serological workup was carried out by standard methods.

Results: A 13-year-old female cancer patient with a pan-reacting autoantibody showed mixed-field agglutination in serological tests. It reacted only on a gel card system that uses BLISS-containing antibiotic co-trimoxazole. Autoantibody was identified as anti-Sda by hemagglutination inhibition test using guinea pig urine.

Conclusion: The autoantibody with anti-Sda specificity was detected on the gel card only in the presence of the antibiotic co-trimoxazole in BLISS.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
56
审稿时长
44 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信