用黄色滤光片评价围周前和早期开角型青光眼患者的视功能。

IF 1.8 Q3 OPHTHALMOLOGY
Clinical Optometry Pub Date : 2025-08-18 eCollection Date: 2025-01-01 DOI:10.2147/OPTO.S520285
George I Triantafyllopoulos, Constantinos H Karabatsas, Evangelos Pateras, Aristeidis Chandrinos, Dimitrios Kapralos, Iordanis Georgiou, Anastasia Tsiogka, Dimitrios Kourkoutas
{"title":"用黄色滤光片评价围周前和早期开角型青光眼患者的视功能。","authors":"George I Triantafyllopoulos, Constantinos H Karabatsas, Evangelos Pateras, Aristeidis Chandrinos, Dimitrios Kapralos, Iordanis Georgiou, Anastasia Tsiogka, Dimitrios Kourkoutas","doi":"10.2147/OPTO.S520285","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to assess the effect of an external yellow-tinted filter (KIROS 1-400 lens) on visual function in patients with pre-perimetric glaucoma (PPG) and early primary open-angle glaucoma (POAG). The primary outcomes were contrast sensitivity (CS) and visual field (VF) indices assessed using standard automated perimetry (SAP).</p><p><strong>Methods: </strong>This comparative observational, within-subject study included 30 patients with PPG (30 eyes) and 50 with POAG (50 eyes) recruited from the Ophthalmology Department of the 401 General Military Hospital, Athens, between January and December 2022. CS was measured using the Pelli-Robson chart. VF indices, including mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI), and Glaucoma Hemifield Test (GHT) classifications, were assessed with SAP with the 24-2 SITA-standard strategy on the Humphrey Field Analyzer II 740. All testing was performed both with and without the yellow filter KIROS 1-400 (Essilor International) in the same eyes.</p><p><strong>Results: </strong>The KIROS 1-400 filter significantly enhanced CS in both PPG and POAG eyes, increasing the median logCS by 0.03. However, while statistically significant, this improvement may not be clinically meaningful. In contrast, no significant changes were observed in the VF indices (MD, PSD, and VFI) when the filter was applied. Analysis of GHT results revealed that the filter reduced borderline classifications and showed high precision (0.733) and recall (0.846) for \"outside normal limits\" classifications. However, the agreement between the filtered and unfiltered GHT results was fair.</p><p><strong>Conclusion: </strong>The KIROS 1-400 filter significantly enhanced CS in patients with PPG and POAG without notable effects on the VF indices. However, caution is advised when interpreting GHT results obtained with yellow-tinted filters. Further studies are recommended to evaluate the filter's long-term clinical benefits and its potential role in glaucoma management.</p>","PeriodicalId":43701,"journal":{"name":"Clinical Optometry","volume":"17 ","pages":"255-268"},"PeriodicalIF":1.8000,"publicationDate":"2025-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12372821/pdf/","citationCount":"0","resultStr":"{\"title\":\"Assessment of Visual Function Using Yellow-Tinted Filter in Patients with Pre-Perimetric and Early Open Angle Glaucoma.\",\"authors\":\"George I Triantafyllopoulos, Constantinos H Karabatsas, Evangelos Pateras, Aristeidis Chandrinos, Dimitrios Kapralos, Iordanis Georgiou, Anastasia Tsiogka, Dimitrios Kourkoutas\",\"doi\":\"10.2147/OPTO.S520285\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to assess the effect of an external yellow-tinted filter (KIROS 1-400 lens) on visual function in patients with pre-perimetric glaucoma (PPG) and early primary open-angle glaucoma (POAG). The primary outcomes were contrast sensitivity (CS) and visual field (VF) indices assessed using standard automated perimetry (SAP).</p><p><strong>Methods: </strong>This comparative observational, within-subject study included 30 patients with PPG (30 eyes) and 50 with POAG (50 eyes) recruited from the Ophthalmology Department of the 401 General Military Hospital, Athens, between January and December 2022. CS was measured using the Pelli-Robson chart. VF indices, including mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI), and Glaucoma Hemifield Test (GHT) classifications, were assessed with SAP with the 24-2 SITA-standard strategy on the Humphrey Field Analyzer II 740. All testing was performed both with and without the yellow filter KIROS 1-400 (Essilor International) in the same eyes.</p><p><strong>Results: </strong>The KIROS 1-400 filter significantly enhanced CS in both PPG and POAG eyes, increasing the median logCS by 0.03. However, while statistically significant, this improvement may not be clinically meaningful. In contrast, no significant changes were observed in the VF indices (MD, PSD, and VFI) when the filter was applied. Analysis of GHT results revealed that the filter reduced borderline classifications and showed high precision (0.733) and recall (0.846) for \\\"outside normal limits\\\" classifications. However, the agreement between the filtered and unfiltered GHT results was fair.</p><p><strong>Conclusion: </strong>The KIROS 1-400 filter significantly enhanced CS in patients with PPG and POAG without notable effects on the VF indices. However, caution is advised when interpreting GHT results obtained with yellow-tinted filters. Further studies are recommended to evaluate the filter's long-term clinical benefits and its potential role in glaucoma management.</p>\",\"PeriodicalId\":43701,\"journal\":{\"name\":\"Clinical Optometry\",\"volume\":\"17 \",\"pages\":\"255-268\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-08-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12372821/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Optometry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/OPTO.S520285\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Optometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTO.S520285","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在评估外植黄色滤光片(KIROS 1-400晶状体)对围周前青光眼(PPG)和早期原发性开角型青光眼(POAG)患者视力功能的影响。主要结果是对比敏感度(CS)和视野(VF)指数,使用标准自动视野测量(SAP)进行评估。方法:这项比较观察性的受试者研究包括30名PPG患者(30只眼)和50名POAG患者(50只眼),这些患者于2022年1月至12月从雅典401军事总医院眼科招募。CS采用Pelli-Robson图测量。VF指数,包括平均偏差(MD)、模式标准差(PSD)、视野指数(VFI)和青光眼半视野测试(GHT)分类,在Humphrey field Analyzer II 740上采用24-2 sita标准策略使用SAP进行评估。所有测试均在同一只眼睛中使用或不使用黄色滤光片KIROS 1-400 (Essilor International)进行。结果:KIROS 1-400滤光片显著提高了PPG眼和POAG眼的CS,使中位logCS提高0.03。然而,虽然统计上有显著性,但这种改善可能没有临床意义。相比之下,当使用过滤器时,VF指数(MD, PSD和VFI)没有明显变化。对GHT结果的分析表明,该滤波器减少了边缘分类,并对“正常范围外”分类显示出较高的精度(0.733)和召回率(0.846)。然而,过滤和未过滤的GHT结果之间的一致性是公平的。结论:KIROS 1-400滤过剂可显著提高PPG和POAG患者的CS,对VF指标无显著影响。然而,在解释用黄色滤光片获得的GHT结果时,建议谨慎。建议进一步研究评估滤光片的长期临床效益及其在青光眼治疗中的潜在作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Assessment of Visual Function Using Yellow-Tinted Filter in Patients with Pre-Perimetric and Early Open Angle Glaucoma.

Assessment of Visual Function Using Yellow-Tinted Filter in Patients with Pre-Perimetric and Early Open Angle Glaucoma.

Assessment of Visual Function Using Yellow-Tinted Filter in Patients with Pre-Perimetric and Early Open Angle Glaucoma.

Purpose: This study aimed to assess the effect of an external yellow-tinted filter (KIROS 1-400 lens) on visual function in patients with pre-perimetric glaucoma (PPG) and early primary open-angle glaucoma (POAG). The primary outcomes were contrast sensitivity (CS) and visual field (VF) indices assessed using standard automated perimetry (SAP).

Methods: This comparative observational, within-subject study included 30 patients with PPG (30 eyes) and 50 with POAG (50 eyes) recruited from the Ophthalmology Department of the 401 General Military Hospital, Athens, between January and December 2022. CS was measured using the Pelli-Robson chart. VF indices, including mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI), and Glaucoma Hemifield Test (GHT) classifications, were assessed with SAP with the 24-2 SITA-standard strategy on the Humphrey Field Analyzer II 740. All testing was performed both with and without the yellow filter KIROS 1-400 (Essilor International) in the same eyes.

Results: The KIROS 1-400 filter significantly enhanced CS in both PPG and POAG eyes, increasing the median logCS by 0.03. However, while statistically significant, this improvement may not be clinically meaningful. In contrast, no significant changes were observed in the VF indices (MD, PSD, and VFI) when the filter was applied. Analysis of GHT results revealed that the filter reduced borderline classifications and showed high precision (0.733) and recall (0.846) for "outside normal limits" classifications. However, the agreement between the filtered and unfiltered GHT results was fair.

Conclusion: The KIROS 1-400 filter significantly enhanced CS in patients with PPG and POAG without notable effects on the VF indices. However, caution is advised when interpreting GHT results obtained with yellow-tinted filters. Further studies are recommended to evaluate the filter's long-term clinical benefits and its potential role in glaucoma management.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Optometry
Clinical Optometry OPHTHALMOLOGY-
CiteScore
3.00
自引率
5.90%
发文量
29
审稿时长
16 weeks
期刊介绍: Clinical Optometry is an international, peer-reviewed, open access journal focusing on clinical optometry. All aspects of patient care are addressed within the journal as well as the practice of optometry including economic and business analyses. Basic and clinical research papers are published that cover all aspects of optics, refraction and its application to the theory and practice of optometry. Specific topics covered in the journal include: Theoretical and applied optics, Delivery of patient care in optometry practice, Refraction and correction of errors, Screening and preventative aspects of eye disease, Extended clinical roles for optometrists including shared care and provision of medications, Teaching and training optometrists, International aspects of optometry, Business practice, Patient adherence, quality of life, satisfaction, Health economic evaluations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信