细胞因子水平在立即加载和卸载微型螺钉:一项裂口随机临床试验。

IF 1.5 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Orthodontics Pub Date : 2025-09-01 Epub Date: 2025-08-25 DOI:10.1177/14653125251358815
Mariah Carboni Mendes, Gabriela Leite Pedroso, Paôla Caroline da Silva Mira, Amanda Cunha Regal Castro, Caio Luiz Bitencourt Reis, Maria Bernadete Sasso Stuani
{"title":"细胞因子水平在立即加载和卸载微型螺钉:一项裂口随机临床试验。","authors":"Mariah Carboni Mendes, Gabriela Leite Pedroso, Paôla Caroline da Silva Mira, Amanda Cunha Regal Castro, Caio Luiz Bitencourt Reis, Maria Bernadete Sasso Stuani","doi":"10.1177/14653125251358815","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare the levels of interleukin (IL)-1 beta (IL-1β), alpha (IL-1α), receptor antagonist (IL-1Ra), IL-10 and IL-13 in peri-mini-screw crevicular fluid (PMCF) between unloaded and immediately loaded mini-screws during orthodontic treatment.</p><p><strong>Design: </strong>Single-centre paired split-mouth controlled trial.</p><p><strong>Participants: </strong>Patients who required at least two mini-screws as a part of their orthodontic treatment at orthodontic clinic of School of Dentistry of Ribeirão Preto, University of São Paulo (USP) were recruited.</p><p><strong>Methods: </strong>A total of 40 mini-screws were inserted into the interradicular alveolar bone in 16 patients. Using the coin toss method, each mini-screw was randomly allocated into one of two groups: a control group of unloaded (n = 20) and a group of immediately loaded mini-screws (n = 20). Immediately postoperatively, a continuous load in the range of 150-200 cN was applied to the mini-screws allocated to the loaded group. The PMCF was collected in four experimental times: immediately postoperatively (and on load time, to mini-screws allocated into the loaded group) and 7, 14 and 21 days postoperatively. Biomarker levels were measured using Multiplex Microsphere Immunoassays and compared between groups and covariates using statistical tests that accounted for multiple observations per participant (alpha =5%).</p><p><strong>Results: </strong>No mini-screws were lost. There was a progressive and statistically significant increase of the biomarker's levels in the two groups during the experimental times (<i>P</i> <0.001). The biomarker levels were significantly higher in the immediately loaded group compared to the unloaded group at all time points (<i>P</i> <0.05), except for IL-10 after 7 days postoperatively.</p><p><strong>Conclusion: </strong>Although all biomarker levels were statistically higher in the immediately loaded group at all experimental time points in comparison with the unloaded group, no mini-screws were lost. This suggests a balanced and normal adaptive bone response to the mechanical stress of immediate loading, with no negative impact on clinical outcomes.</p>","PeriodicalId":16677,"journal":{"name":"Journal of Orthodontics","volume":" ","pages":"275-284"},"PeriodicalIF":1.5000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cytokine levels in immediate loaded and unloaded mini-screw: A split-mouth randomised clinical trial.\",\"authors\":\"Mariah Carboni Mendes, Gabriela Leite Pedroso, Paôla Caroline da Silva Mira, Amanda Cunha Regal Castro, Caio Luiz Bitencourt Reis, Maria Bernadete Sasso Stuani\",\"doi\":\"10.1177/14653125251358815\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To compare the levels of interleukin (IL)-1 beta (IL-1β), alpha (IL-1α), receptor antagonist (IL-1Ra), IL-10 and IL-13 in peri-mini-screw crevicular fluid (PMCF) between unloaded and immediately loaded mini-screws during orthodontic treatment.</p><p><strong>Design: </strong>Single-centre paired split-mouth controlled trial.</p><p><strong>Participants: </strong>Patients who required at least two mini-screws as a part of their orthodontic treatment at orthodontic clinic of School of Dentistry of Ribeirão Preto, University of São Paulo (USP) were recruited.</p><p><strong>Methods: </strong>A total of 40 mini-screws were inserted into the interradicular alveolar bone in 16 patients. Using the coin toss method, each mini-screw was randomly allocated into one of two groups: a control group of unloaded (n = 20) and a group of immediately loaded mini-screws (n = 20). Immediately postoperatively, a continuous load in the range of 150-200 cN was applied to the mini-screws allocated to the loaded group. The PMCF was collected in four experimental times: immediately postoperatively (and on load time, to mini-screws allocated into the loaded group) and 7, 14 and 21 days postoperatively. Biomarker levels were measured using Multiplex Microsphere Immunoassays and compared between groups and covariates using statistical tests that accounted for multiple observations per participant (alpha =5%).</p><p><strong>Results: </strong>No mini-screws were lost. There was a progressive and statistically significant increase of the biomarker's levels in the two groups during the experimental times (<i>P</i> <0.001). The biomarker levels were significantly higher in the immediately loaded group compared to the unloaded group at all time points (<i>P</i> <0.05), except for IL-10 after 7 days postoperatively.</p><p><strong>Conclusion: </strong>Although all biomarker levels were statistically higher in the immediately loaded group at all experimental time points in comparison with the unloaded group, no mini-screws were lost. This suggests a balanced and normal adaptive bone response to the mechanical stress of immediate loading, with no negative impact on clinical outcomes.</p>\",\"PeriodicalId\":16677,\"journal\":{\"name\":\"Journal of Orthodontics\",\"volume\":\" \",\"pages\":\"275-284\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/14653125251358815\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/8/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/14653125251358815","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较正畸治疗中未加载与即刻加载微型螺钉前后微型螺钉周围沟液(PMCF)中白细胞介素(IL)-1 β (IL-1β)、α (IL-1α)、受体拮抗剂(IL- 1ra)、IL-10和IL-13的水平。设计:单中心配对裂口对照试验。参与者:在巴西圣保罗大学(USP) ribebe o Preto牙科学院正畸诊所接受正畸治疗的患者,至少需要两个微型螺钉。方法:对16例患者进行根间牙槽骨内固定微型螺钉40枚。采用抛硬币的方法,将每个微型螺钉随机分为两组:未加载的对照组(n = 20)和立即加载的微型螺钉组(n = 20)。术后立即对分配给加载组的微型螺钉施加150-200 cN的连续负荷。PMCF在四个实验时间收集:术后立即(和加载时间,分配到加载组的微型螺钉)和术后7、14和21天。使用多重微球免疫测定法测量生物标志物水平,并使用统计检验在组间和协变量之间进行比较,统计检验占每个参与者的多个观察值(α =5%)。结果:无微型螺钉丢失。两组在实验时间内的生物标志物水平均有进进性和统计学意义上的升高(P P结论:尽管在所有实验时间点,立即加载组的生物标志物水平均高于未加载组,但没有微型螺钉丢失。这表明对即刻负荷的机械应力有平衡和正常的适应性骨反应,对临床结果没有负面影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cytokine levels in immediate loaded and unloaded mini-screw: A split-mouth randomised clinical trial.

Objective: To compare the levels of interleukin (IL)-1 beta (IL-1β), alpha (IL-1α), receptor antagonist (IL-1Ra), IL-10 and IL-13 in peri-mini-screw crevicular fluid (PMCF) between unloaded and immediately loaded mini-screws during orthodontic treatment.

Design: Single-centre paired split-mouth controlled trial.

Participants: Patients who required at least two mini-screws as a part of their orthodontic treatment at orthodontic clinic of School of Dentistry of Ribeirão Preto, University of São Paulo (USP) were recruited.

Methods: A total of 40 mini-screws were inserted into the interradicular alveolar bone in 16 patients. Using the coin toss method, each mini-screw was randomly allocated into one of two groups: a control group of unloaded (n = 20) and a group of immediately loaded mini-screws (n = 20). Immediately postoperatively, a continuous load in the range of 150-200 cN was applied to the mini-screws allocated to the loaded group. The PMCF was collected in four experimental times: immediately postoperatively (and on load time, to mini-screws allocated into the loaded group) and 7, 14 and 21 days postoperatively. Biomarker levels were measured using Multiplex Microsphere Immunoassays and compared between groups and covariates using statistical tests that accounted for multiple observations per participant (alpha =5%).

Results: No mini-screws were lost. There was a progressive and statistically significant increase of the biomarker's levels in the two groups during the experimental times (P <0.001). The biomarker levels were significantly higher in the immediately loaded group compared to the unloaded group at all time points (P <0.05), except for IL-10 after 7 days postoperatively.

Conclusion: Although all biomarker levels were statistically higher in the immediately loaded group at all experimental time points in comparison with the unloaded group, no mini-screws were lost. This suggests a balanced and normal adaptive bone response to the mechanical stress of immediate loading, with no negative impact on clinical outcomes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Orthodontics
Journal of Orthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.60
自引率
15.40%
发文量
55
期刊介绍: The Journal of Orthodontics has an international circulation, publishing papers from throughout the world. The official journal of the British Orthodontic Society, it aims to publish high quality, evidence-based, clinically orientated or clinically relevant original research papers that will underpin evidence based orthodontic care. It particularly welcomes reports on prospective research into different treatment methods and techniques but also systematic reviews, meta-analyses and studies which will stimulate interest in new developments. Regular features include original papers on clinically relevant topics, clinical case reports, reviews of the orthodontic literature, editorials, book reviews, correspondence and other features of interest to the orthodontic community. The Journal is published in full colour throughout.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信