{"title":"有或无水平预备牙体固定修复体抗压强度的实验研究。","authors":"Lucia Alexandra Drăghici, Raluca Monica Comăneanu, Diana Vrânceanu, Florin Baciu, Mirel Stoian-Albulescu, Anca Monica Dobrescu, Tudor Petru Ionescu, Cherana Gioga","doi":"10.25122/jml-2025-0124","DOIUrl":null,"url":null,"abstract":"<p><p>Fixed prosthetic restorations, particularly those made entirely of zirconia, are widely used in clinical dental practice for the restoration of natural teeth. Their success largely depends on the design of the tooth preparation, especially the type of finish line, as well as the restoration's ability to withstand occlusal forces during mastication. Over 12 months, a total of 21 extracted teeth were initially collected, from which six were selected for this study. To achieve the objective of the study, three teeth were prepared with a horizontal finish line (shoulder), and the remaining three were prepared without a defined finish line (vertical preparation). For each prepared tooth, three full-contour zirconia crowns were fabricated. To ensure accurate comparison and standardization of occlusal force application during mechanical testing, all crowns were designed with identical morphology. The force application device used in mechanical testing was digitally designed to replicate the anatomy of the antagonistic teeth corresponding to each tested crown. Samples I and III showed significant structural changes, including horizontal fractures at the cervical level. Samples II, 1, and 2 exhibited no visible damage. The maximum recorded compressive forces at which structural failure occurred varied widely, ranging between 180 N and 2537 N. Consequently, all samples that recorded fracture values below 1000 N were analyzed separately for interpretation. The findings of this experimental study indicate that tooth preparation design significantly influences the compressive strength of monolithic zirconia crowns. Both preparation types-shouldered and shoulderless-demonstrated high resistance values, with a slight advantage observed in favor of the preparations with a defined finish line (shoulder).</p>","PeriodicalId":16386,"journal":{"name":"Journal of Medicine and Life","volume":"18 7","pages":"671-677"},"PeriodicalIF":0.0000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12393302/pdf/","citationCount":"0","resultStr":"{\"title\":\"Experimental study on the compressive strength of fixed prosthetic restorations on tooth preparations with or without horizontal preparation.\",\"authors\":\"Lucia Alexandra Drăghici, Raluca Monica Comăneanu, Diana Vrânceanu, Florin Baciu, Mirel Stoian-Albulescu, Anca Monica Dobrescu, Tudor Petru Ionescu, Cherana Gioga\",\"doi\":\"10.25122/jml-2025-0124\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fixed prosthetic restorations, particularly those made entirely of zirconia, are widely used in clinical dental practice for the restoration of natural teeth. Their success largely depends on the design of the tooth preparation, especially the type of finish line, as well as the restoration's ability to withstand occlusal forces during mastication. Over 12 months, a total of 21 extracted teeth were initially collected, from which six were selected for this study. To achieve the objective of the study, three teeth were prepared with a horizontal finish line (shoulder), and the remaining three were prepared without a defined finish line (vertical preparation). For each prepared tooth, three full-contour zirconia crowns were fabricated. To ensure accurate comparison and standardization of occlusal force application during mechanical testing, all crowns were designed with identical morphology. The force application device used in mechanical testing was digitally designed to replicate the anatomy of the antagonistic teeth corresponding to each tested crown. Samples I and III showed significant structural changes, including horizontal fractures at the cervical level. Samples II, 1, and 2 exhibited no visible damage. The maximum recorded compressive forces at which structural failure occurred varied widely, ranging between 180 N and 2537 N. Consequently, all samples that recorded fracture values below 1000 N were analyzed separately for interpretation. The findings of this experimental study indicate that tooth preparation design significantly influences the compressive strength of monolithic zirconia crowns. Both preparation types-shouldered and shoulderless-demonstrated high resistance values, with a slight advantage observed in favor of the preparations with a defined finish line (shoulder).</p>\",\"PeriodicalId\":16386,\"journal\":{\"name\":\"Journal of Medicine and Life\",\"volume\":\"18 7\",\"pages\":\"671-677\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12393302/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medicine and Life\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25122/jml-2025-0124\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medicine and Life","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25122/jml-2025-0124","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

固定修复体,特别是完全由氧化锆制成的修复体,在临床牙科实践中广泛应用于自然牙的修复。他们的成功很大程度上取决于牙齿准备的设计,特别是终点线的类型,以及修复体在咀嚼过程中承受咬合力的能力。在12个月的时间里,总共收集了21颗拔除的牙齿,从中选择了6颗用于本研究。为了达到研究的目的,三颗牙齿在水平终点线(肩部)准备,其余三颗牙齿在没有确定终点线(垂直准备)的情况下准备。每颗预备的牙齿,制作三个全轮廓的氧化锆冠。为了保证力学测试中咬合力施加的准确比较和标准化,所有冠都设计成相同的形态。机械测试中使用的力施加装置是数字化设计的,以复制对应于每个测试冠的拮抗牙的解剖结构。样本I和III显示明显的结构改变,包括颈椎水平骨折。样品II、1和2没有明显的损伤。记录到的导致结构破坏的最大压缩力变化很大,范围在180 N到2537 N之间,因此,所有记录到1000 N以下断裂值的样品都被单独分析以进行解释。实验结果表明,牙体制备设计对整体氧化锆冠的抗压强度有显著影响。两种制备类型(肩式和无肩式)均表现出较高的阻力值,具有确定终点线(肩式)的制备具有轻微的优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Experimental study on the compressive strength of fixed prosthetic restorations on tooth preparations with or without horizontal preparation.

Experimental study on the compressive strength of fixed prosthetic restorations on tooth preparations with or without horizontal preparation.

Experimental study on the compressive strength of fixed prosthetic restorations on tooth preparations with or without horizontal preparation.

Experimental study on the compressive strength of fixed prosthetic restorations on tooth preparations with or without horizontal preparation.

Fixed prosthetic restorations, particularly those made entirely of zirconia, are widely used in clinical dental practice for the restoration of natural teeth. Their success largely depends on the design of the tooth preparation, especially the type of finish line, as well as the restoration's ability to withstand occlusal forces during mastication. Over 12 months, a total of 21 extracted teeth were initially collected, from which six were selected for this study. To achieve the objective of the study, three teeth were prepared with a horizontal finish line (shoulder), and the remaining three were prepared without a defined finish line (vertical preparation). For each prepared tooth, three full-contour zirconia crowns were fabricated. To ensure accurate comparison and standardization of occlusal force application during mechanical testing, all crowns were designed with identical morphology. The force application device used in mechanical testing was digitally designed to replicate the anatomy of the antagonistic teeth corresponding to each tested crown. Samples I and III showed significant structural changes, including horizontal fractures at the cervical level. Samples II, 1, and 2 exhibited no visible damage. The maximum recorded compressive forces at which structural failure occurred varied widely, ranging between 180 N and 2537 N. Consequently, all samples that recorded fracture values below 1000 N were analyzed separately for interpretation. The findings of this experimental study indicate that tooth preparation design significantly influences the compressive strength of monolithic zirconia crowns. Both preparation types-shouldered and shoulderless-demonstrated high resistance values, with a slight advantage observed in favor of the preparations with a defined finish line (shoulder).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medicine and Life
Journal of Medicine and Life Medicine-Medicine (all)
CiteScore
1.90
自引率
0.00%
发文量
202
期刊介绍: The Journal of Medicine and Life publishes peer-reviewed articles from various fields of medicine and life sciences, including original research, systematic reviews, special reports, case presentations, major medical breakthroughs and letters to the editor. The Journal focuses on current matters that lie at the intersection of biomedical science and clinical practice and strives to present this information to inform health care delivery and improve patient outcomes. Papers addressing topics such as neuroprotection, neurorehabilitation, neuroplasticity, and neuroregeneration are particularly encouraged, as part of the Journal''s continuous interest in neuroscience research. The Editorial Board of the Journal of Medicine and Life is open to consider manuscripts from all levels of research and areas of biological sciences, including fundamental, experimental or clinical research and matters of public health. As part of our pledge to promote an educational and community-building environment, our issues feature sections designated to informing our readers regarding exciting international congresses, teaching courses and relevant institutional-level events.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信