{"title":"髋臼周围假体周围骨折。","authors":"Sahil Batra, Rajesh Malhotra","doi":"10.1007/s43465-025-01380-y","DOIUrl":null,"url":null,"abstract":"<p><p>Peri-Prosthetic acetabular fractures are rare but challenging Complications related to total hip arthroplasty (THA), especially during revision procedures. Factors contributing to these fractures include poor bone quality, prior implant placement, and increased mechanical stress. Several systems classify these fractures and management strategies differ based on whether the fracture occurs intraoperatively or postoperatively and whether the prosthesis is stable/unstable. Undisplaced fractures may be managed conservatively, while displaced fractures often require surgical intervention, such as open reduction and internal fixation (ORIF), alongside implant revision. The modern porous coated cups along with other reconstruction techniques have improved the outcomes. The complications include non-union, implant loosening, deep infection, dislocation.</p>","PeriodicalId":13338,"journal":{"name":"Indian Journal of Orthopaedics","volume":"59 8","pages":"1164-1171"},"PeriodicalIF":1.1000,"publicationDate":"2025-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12367609/pdf/","citationCount":"0","resultStr":"{\"title\":\"Periprosthetic Fractures Around the Acetabulum.\",\"authors\":\"Sahil Batra, Rajesh Malhotra\",\"doi\":\"10.1007/s43465-025-01380-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Peri-Prosthetic acetabular fractures are rare but challenging Complications related to total hip arthroplasty (THA), especially during revision procedures. Factors contributing to these fractures include poor bone quality, prior implant placement, and increased mechanical stress. Several systems classify these fractures and management strategies differ based on whether the fracture occurs intraoperatively or postoperatively and whether the prosthesis is stable/unstable. Undisplaced fractures may be managed conservatively, while displaced fractures often require surgical intervention, such as open reduction and internal fixation (ORIF), alongside implant revision. The modern porous coated cups along with other reconstruction techniques have improved the outcomes. The complications include non-union, implant loosening, deep infection, dislocation.</p>\",\"PeriodicalId\":13338,\"journal\":{\"name\":\"Indian Journal of Orthopaedics\",\"volume\":\"59 8\",\"pages\":\"1164-1171\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2025-04-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12367609/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Orthopaedics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s43465-025-01380-y\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/8/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Orthopaedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s43465-025-01380-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Peri-Prosthetic acetabular fractures are rare but challenging Complications related to total hip arthroplasty (THA), especially during revision procedures. Factors contributing to these fractures include poor bone quality, prior implant placement, and increased mechanical stress. Several systems classify these fractures and management strategies differ based on whether the fracture occurs intraoperatively or postoperatively and whether the prosthesis is stable/unstable. Undisplaced fractures may be managed conservatively, while displaced fractures often require surgical intervention, such as open reduction and internal fixation (ORIF), alongside implant revision. The modern porous coated cups along with other reconstruction techniques have improved the outcomes. The complications include non-union, implant loosening, deep infection, dislocation.
期刊介绍:
IJO welcomes articles that contribute to Orthopaedic knowledge from India and overseas. We publish articles dealing with clinical orthopaedics and basic research in orthopaedic surgery. Articles are accepted only for exclusive publication in the Indian Journal of Orthopaedics. Previously published articles, articles which are in peer-reviewed electronic publications in other journals, are not accepted by the Journal. Published articles and illustrations become the property of the Journal. The copyright remains with the journal. Studies must be carried out in accordance with World Medical Association Declaration of Helsinki.