三种NiTi旋转系统的多模态评估:临床模拟、机械测试和有限元分析。

IF 3.1 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Jesus A Aparicio, Pedro M Mendez S, Giulia Malvicini, Simone Grandini, Carlo Gaeta, Ana Paula García Guerrero, Kristel Lidice Miranda Robles, José Aranguren, Alejandro R Pérez
{"title":"三种NiTi旋转系统的多模态评估:临床模拟、机械测试和有限元分析。","authors":"Jesus A Aparicio, Pedro M Mendez S, Giulia Malvicini, Simone Grandini, Carlo Gaeta, Ana Paula García Guerrero, Kristel Lidice Miranda Robles, José Aranguren, Alejandro R Pérez","doi":"10.3390/dj13080368","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objectives:</b> This study aimed to compare the clinical durability, mechanical performance, and stress behavior of three NiTi rotary systems-BlueShaper (Blue), BlueShaper Pro (Dual Wire), and BlueShaper Gold (fully gold-treated NiTi)-through a multimodal evaluation that included simulated instrumentation in 3D-printed replicas, mechanical testing, and finite element analysis (FEA). <b>Methods:</b> Sixty instruments (n = 20 per group) were tested. Simulated canal preparation was conducted in standardized 3D-printed mandibular molars with a 40° mesial root curvature until fracture occurred. Mechanical tests included torsional and flexural loading using a universal testing machine and stainless steel blocks with a standardized 40° curvature. FEA simulations evaluated von Mises stress, shear stress, total deformation, cyclic fatigue behavior, and contact pressure between the instrument and canal wall. <b>Results:</b> BlueShaper Gold prepared an average of 7.5 canals before fracture, followed by BlueShaper Pro (5.67 canals) and Blue (5.00 canals) (<i>p</i> < 0.001). Gold exhibited the highest torsional resistance (6.08 ± 3.08 N) and the longest fatigue life (325 ± 55.7 cycles), with the lowest von Mises stress and damage factor in FEA. BlueShaper Pro showed the longest time to fracture in mechanical testing (73.85 ± 7.10 s) and balanced mechanical behavior. Blue demonstrated the lowest performance across most parameters, including the shortest fatigue life and highest stress concentration. <b>Conclusions:</b> BlueShaper Gold exhibited the highest mechanical strength and fatigue resistance. BlueShaper Pro demonstrated the longest fatigue life and balanced mechanical behavior. Blue showed the lowest performance across most parameters. The strong correlation among clinical, mechanical, and FEA data reinforces the critical role of alloy composition in determining instrument durability, even when design remains constant.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":"13 8","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2025-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12385140/pdf/","citationCount":"0","resultStr":"{\"title\":\"Multimodal Evaluation of Three NiTi Rotary Systems: Clinical Simulation, Mechanical Testing, and Finite Element Analysis.\",\"authors\":\"Jesus A Aparicio, Pedro M Mendez S, Giulia Malvicini, Simone Grandini, Carlo Gaeta, Ana Paula García Guerrero, Kristel Lidice Miranda Robles, José Aranguren, Alejandro R Pérez\",\"doi\":\"10.3390/dj13080368\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objectives:</b> This study aimed to compare the clinical durability, mechanical performance, and stress behavior of three NiTi rotary systems-BlueShaper (Blue), BlueShaper Pro (Dual Wire), and BlueShaper Gold (fully gold-treated NiTi)-through a multimodal evaluation that included simulated instrumentation in 3D-printed replicas, mechanical testing, and finite element analysis (FEA). <b>Methods:</b> Sixty instruments (n = 20 per group) were tested. Simulated canal preparation was conducted in standardized 3D-printed mandibular molars with a 40° mesial root curvature until fracture occurred. Mechanical tests included torsional and flexural loading using a universal testing machine and stainless steel blocks with a standardized 40° curvature. FEA simulations evaluated von Mises stress, shear stress, total deformation, cyclic fatigue behavior, and contact pressure between the instrument and canal wall. <b>Results:</b> BlueShaper Gold prepared an average of 7.5 canals before fracture, followed by BlueShaper Pro (5.67 canals) and Blue (5.00 canals) (<i>p</i> < 0.001). Gold exhibited the highest torsional resistance (6.08 ± 3.08 N) and the longest fatigue life (325 ± 55.7 cycles), with the lowest von Mises stress and damage factor in FEA. BlueShaper Pro showed the longest time to fracture in mechanical testing (73.85 ± 7.10 s) and balanced mechanical behavior. Blue demonstrated the lowest performance across most parameters, including the shortest fatigue life and highest stress concentration. <b>Conclusions:</b> BlueShaper Gold exhibited the highest mechanical strength and fatigue resistance. BlueShaper Pro demonstrated the longest fatigue life and balanced mechanical behavior. Blue showed the lowest performance across most parameters. The strong correlation among clinical, mechanical, and FEA data reinforces the critical role of alloy composition in determining instrument durability, even when design remains constant.</p>\",\"PeriodicalId\":11269,\"journal\":{\"name\":\"Dentistry Journal\",\"volume\":\"13 8\",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2025-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12385140/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dentistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/dj13080368\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj13080368","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在通过多模态评估,包括3d打印复制品中的模拟仪器、机械测试和有限元分析(FEA),比较三种镍钛旋转系统——BlueShaper(蓝色)、BlueShaper Pro(双丝)和BlueShaper Gold(全金处理的镍钛)的临床耐久性、机械性能和应力行为。方法:共检测仪器60台,每组20台。在标准化的3d打印下颌磨牙中进行模拟管制备,下颌磨牙的近中根曲率为40°,直到发生骨折。机械测试包括使用万能试验机和具有标准40°曲率的不锈钢块进行扭转和弯曲加载。有限元模拟评估了von Mises应力、剪切应力、总变形、循环疲劳行为以及仪器与管壁之间的接触压力。结果:骨折前BlueShaper Gold平均准备7.5根管,其次是BlueShaper Pro(5.67根管)和Blue(5.00根管)(p < 0.001)。在有限元分析中,金的抗扭性能最高(6.08±3.08 N),疲劳寿命最长(325±55.7次),von Mises应力和损伤系数最低。在力学测试中,BlueShaper Pro的断裂时间最长(73.85±7.10 s),力学性能平衡。蓝色在大多数参数上表现最差,包括最短的疲劳寿命和最高的应力集中。结论:BlueShaper Gold具有最高的机械强度和抗疲劳性能。BlueShaper Pro具有最长的疲劳寿命和平衡的力学性能。蓝色在大多数参数中表现最差。临床、机械和有限元数据之间的强相关性强化了合金成分在决定仪器耐久性方面的关键作用,即使在设计保持不变的情况下也是如此。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Multimodal Evaluation of Three NiTi Rotary Systems: Clinical Simulation, Mechanical Testing, and Finite Element Analysis.

Multimodal Evaluation of Three NiTi Rotary Systems: Clinical Simulation, Mechanical Testing, and Finite Element Analysis.

Multimodal Evaluation of Three NiTi Rotary Systems: Clinical Simulation, Mechanical Testing, and Finite Element Analysis.

Multimodal Evaluation of Three NiTi Rotary Systems: Clinical Simulation, Mechanical Testing, and Finite Element Analysis.

Objectives: This study aimed to compare the clinical durability, mechanical performance, and stress behavior of three NiTi rotary systems-BlueShaper (Blue), BlueShaper Pro (Dual Wire), and BlueShaper Gold (fully gold-treated NiTi)-through a multimodal evaluation that included simulated instrumentation in 3D-printed replicas, mechanical testing, and finite element analysis (FEA). Methods: Sixty instruments (n = 20 per group) were tested. Simulated canal preparation was conducted in standardized 3D-printed mandibular molars with a 40° mesial root curvature until fracture occurred. Mechanical tests included torsional and flexural loading using a universal testing machine and stainless steel blocks with a standardized 40° curvature. FEA simulations evaluated von Mises stress, shear stress, total deformation, cyclic fatigue behavior, and contact pressure between the instrument and canal wall. Results: BlueShaper Gold prepared an average of 7.5 canals before fracture, followed by BlueShaper Pro (5.67 canals) and Blue (5.00 canals) (p < 0.001). Gold exhibited the highest torsional resistance (6.08 ± 3.08 N) and the longest fatigue life (325 ± 55.7 cycles), with the lowest von Mises stress and damage factor in FEA. BlueShaper Pro showed the longest time to fracture in mechanical testing (73.85 ± 7.10 s) and balanced mechanical behavior. Blue demonstrated the lowest performance across most parameters, including the shortest fatigue life and highest stress concentration. Conclusions: BlueShaper Gold exhibited the highest mechanical strength and fatigue resistance. BlueShaper Pro demonstrated the longest fatigue life and balanced mechanical behavior. Blue showed the lowest performance across most parameters. The strong correlation among clinical, mechanical, and FEA data reinforces the critical role of alloy composition in determining instrument durability, even when design remains constant.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dentistry Journal
Dentistry Journal Dentistry-Dentistry (all)
CiteScore
3.70
自引率
7.70%
发文量
213
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信