2253例儿童和成人经导管多腔与单腔封闭第二口房间隔缺损的比较

IF 2.2 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Grégoire Albenque , Mohamed Jaber , Estíbaliz Valdeolmillos , Marine Cachanado , Jerome Petit , clement Batteux , Sebastien Hascoet
{"title":"2253例儿童和成人经导管多腔与单腔封闭第二口房间隔缺损的比较","authors":"Grégoire Albenque ,&nbsp;Mohamed Jaber ,&nbsp;Estíbaliz Valdeolmillos ,&nbsp;Marine Cachanado ,&nbsp;Jerome Petit ,&nbsp;clement Batteux ,&nbsp;Sebastien Hascoet","doi":"10.1016/j.acvd.2025.06.043","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Transcatheter closure of ostium secundum atrial septal defect (osASD) is the first-line treatment in most children and adults. However, the use of multiple devices during the same procedure is uncommon, and data on the feasibility and safety of this approach remain limited. This study aims to assess the outcomes of osASD closure using multiple devices.</div></div><div><h3>Method</h3><div>This prospective, single-center cohort study included patients who underwent transcatheter osASD closure with an Amplatzer Septal Occluder (ASO) between May 1998 and December 2021 at Marie Lannelongue Hospital. Periprocedural data and major adverse events (MAEs) were retrospectively analyzed. A comparison was then made between patients who received a single device versus multiple devices.</div></div><div><h3>Results</h3><div>Among 2,253 patients, 216 (9.6%) had complex osASD, including 6.4% with double osASD and 3.7% with multi-fenestrated osASD. Multiple devices were implanted in 19 patients (0.8%), including four pediatric cases. One 53-year-old patient was implanted with three devices (ASO sizes 20, 12, and 10<!--> <!-->mm). Patients with multiple devices were more likely to have an interatrial septal aneurysm (OR 3.54 [1.38−9.06], <em>p</em> <!-->=<!--> <!-->0.008). Procedural success was 100%, with no major adverse events in these patients. No significant differences in minor complications, atrial tachycardia, residual shunt, or pericardial effusion were observed between groups. Long-term follow-up of 6.2 years showed no deaths, cardiac reinterventions, significant residual shunts, thromboembolic events, atrial arrhythmias, or conduction disturbances in the multiple-device group.</div></div><div><h3>Conclusion</h3><div>Transcatheter closure of complex osASD using multiple devices is a feasible and safe approach, with excellent procedural and long-term outcomes when required.</div></div>","PeriodicalId":55472,"journal":{"name":"Archives of Cardiovascular Diseases","volume":"118 8","pages":"Pages S269-S270"},"PeriodicalIF":2.2000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of transcatheter closure of ostium secundum atrial septal defects with multiple versus single device in 2,253 children and adults\",\"authors\":\"Grégoire Albenque ,&nbsp;Mohamed Jaber ,&nbsp;Estíbaliz Valdeolmillos ,&nbsp;Marine Cachanado ,&nbsp;Jerome Petit ,&nbsp;clement Batteux ,&nbsp;Sebastien Hascoet\",\"doi\":\"10.1016/j.acvd.2025.06.043\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><div>Transcatheter closure of ostium secundum atrial septal defect (osASD) is the first-line treatment in most children and adults. However, the use of multiple devices during the same procedure is uncommon, and data on the feasibility and safety of this approach remain limited. This study aims to assess the outcomes of osASD closure using multiple devices.</div></div><div><h3>Method</h3><div>This prospective, single-center cohort study included patients who underwent transcatheter osASD closure with an Amplatzer Septal Occluder (ASO) between May 1998 and December 2021 at Marie Lannelongue Hospital. Periprocedural data and major adverse events (MAEs) were retrospectively analyzed. A comparison was then made between patients who received a single device versus multiple devices.</div></div><div><h3>Results</h3><div>Among 2,253 patients, 216 (9.6%) had complex osASD, including 6.4% with double osASD and 3.7% with multi-fenestrated osASD. Multiple devices were implanted in 19 patients (0.8%), including four pediatric cases. One 53-year-old patient was implanted with three devices (ASO sizes 20, 12, and 10<!--> <!-->mm). Patients with multiple devices were more likely to have an interatrial septal aneurysm (OR 3.54 [1.38−9.06], <em>p</em> <!-->=<!--> <!-->0.008). Procedural success was 100%, with no major adverse events in these patients. No significant differences in minor complications, atrial tachycardia, residual shunt, or pericardial effusion were observed between groups. Long-term follow-up of 6.2 years showed no deaths, cardiac reinterventions, significant residual shunts, thromboembolic events, atrial arrhythmias, or conduction disturbances in the multiple-device group.</div></div><div><h3>Conclusion</h3><div>Transcatheter closure of complex osASD using multiple devices is a feasible and safe approach, with excellent procedural and long-term outcomes when required.</div></div>\",\"PeriodicalId\":55472,\"journal\":{\"name\":\"Archives of Cardiovascular Diseases\",\"volume\":\"118 8\",\"pages\":\"Pages S269-S270\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Cardiovascular Diseases\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1875213625003705\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Cardiovascular Diseases","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1875213625003705","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

经导管关闭第二口房间隔缺损(osASD)是大多数儿童和成人的一线治疗方法。然而,在同一手术过程中使用多个器械是不常见的,关于这种方法的可行性和安全性的数据仍然有限。本研究旨在评估使用多种装置闭合osASD的结果。方法本前瞻性单中心队列研究纳入了1998年5月至2021年12月在Marie Lannelongue医院接受Amplatzer室间隔闭塞器(ASO)经导管osASD闭合的患者。回顾性分析围手术期资料和主要不良事件(MAEs)。然后对接受单一装置和多个装置的患者进行比较。结果2253例患者中,有216例(9.6%)为复合性osASD,其中双窗osASD为6.4%,多窗osASD为3.7%。19例患者(0.8%)植入多个装置,其中4例为儿科病例。1例53岁患者植入3个器械(ASO尺寸分别为20,12和10mm)。使用多种装置的患者更容易发生房间隔动脉瘤(OR 3.54[1.38−9.06],p = 0.008)。手术成功率为100%,无重大不良事件发生。两组间轻微并发症、房性心动过速、残留分流或心包积液无显著差异。6.2年的长期随访显示,多装置组无死亡、心脏再介入、明显残余分流、血栓栓塞事件、心房心律失常或传导障碍。结论多器械经导管封堵复杂osASD是一种可行、安全的方法,具有良好的手术效果和远期疗效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of transcatheter closure of ostium secundum atrial septal defects with multiple versus single device in 2,253 children and adults

Introduction

Transcatheter closure of ostium secundum atrial septal defect (osASD) is the first-line treatment in most children and adults. However, the use of multiple devices during the same procedure is uncommon, and data on the feasibility and safety of this approach remain limited. This study aims to assess the outcomes of osASD closure using multiple devices.

Method

This prospective, single-center cohort study included patients who underwent transcatheter osASD closure with an Amplatzer Septal Occluder (ASO) between May 1998 and December 2021 at Marie Lannelongue Hospital. Periprocedural data and major adverse events (MAEs) were retrospectively analyzed. A comparison was then made between patients who received a single device versus multiple devices.

Results

Among 2,253 patients, 216 (9.6%) had complex osASD, including 6.4% with double osASD and 3.7% with multi-fenestrated osASD. Multiple devices were implanted in 19 patients (0.8%), including four pediatric cases. One 53-year-old patient was implanted with three devices (ASO sizes 20, 12, and 10 mm). Patients with multiple devices were more likely to have an interatrial septal aneurysm (OR 3.54 [1.38−9.06], p = 0.008). Procedural success was 100%, with no major adverse events in these patients. No significant differences in minor complications, atrial tachycardia, residual shunt, or pericardial effusion were observed between groups. Long-term follow-up of 6.2 years showed no deaths, cardiac reinterventions, significant residual shunts, thromboembolic events, atrial arrhythmias, or conduction disturbances in the multiple-device group.

Conclusion

Transcatheter closure of complex osASD using multiple devices is a feasible and safe approach, with excellent procedural and long-term outcomes when required.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Archives of Cardiovascular Diseases
Archives of Cardiovascular Diseases 医学-心血管系统
CiteScore
4.40
自引率
6.70%
发文量
87
审稿时长
34 days
期刊介绍: The Journal publishes original peer-reviewed clinical and research articles, epidemiological studies, new methodological clinical approaches, review articles and editorials. Topics covered include coronary artery and valve diseases, interventional and pediatric cardiology, cardiovascular surgery, cardiomyopathy and heart failure, arrhythmias and stimulation, cardiovascular imaging, vascular medicine and hypertension, epidemiology and risk factors, and large multicenter studies. Archives of Cardiovascular Diseases also publishes abstracts of papers presented at the annual sessions of the Journées Européennes de la Société Française de Cardiologie and the guidelines edited by the French Society of Cardiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信