基于HFABP的电化学免疫传感器用于中药药物性心脏毒性的早期检测

IF 5.3 2区 化学 Q1 CHEMISTRY, ANALYTICAL
Bolu Sun, Jiali Kang, Zixia Wang, Yuqiong Wu, Haiying He, Xinlan Wang, Xuanxiu Da, Miao Zhou, Ying Lv, Chenyu Qin, Xiangdong Wang, Lin Yang, Huajie Li, Hai Wang
{"title":"基于HFABP的电化学免疫传感器用于中药药物性心脏毒性的早期检测","authors":"Bolu Sun,&nbsp;Jiali Kang,&nbsp;Zixia Wang,&nbsp;Yuqiong Wu,&nbsp;Haiying He,&nbsp;Xinlan Wang,&nbsp;Xuanxiu Da,&nbsp;Miao Zhou,&nbsp;Ying Lv,&nbsp;Chenyu Qin,&nbsp;Xiangdong Wang,&nbsp;Lin Yang,&nbsp;Huajie Li,&nbsp;Hai Wang","doi":"10.1007/s00604-025-07420-6","DOIUrl":null,"url":null,"abstract":"<div><p>An electrochemical immunosensor was successfully developed for evaluating traditional Chinese medicine (TCM)-induced cardiac toxicity by immobilizing heart-type fatty acid-binding protein (HFABP)-specific antibodies on an electrode surface modified with chitosan (CS)-functionalized metal–organic framework ZIF-8 and gold nanoparticles (AuNPs). Leveraging the excellent biocompatibility of AuNPs, the excellent stability and high surface area of ZIF-8, along with the strong specific recognition capability of HFABP antibodies, the sensor demonstrated superior performance. Under optimized experimental conditions, it achieved an ultra-low detection limit of 7.09 × 10<sup>−2</sup> pg mL<sup>−1</sup> for HFABP, maintained excellent linearity in the range 1.57 × 10<sup>−2</sup> ~ 1.60 × 10<sup>1</sup> ng mL<sup>−1</sup>, and outperformed conventional ELISA methods in sensitivity when applied to TCM-induced cardiac toxicity models. The sensor also demonstrated excellent specificity, reproducibility, and stability. This research provides a sensitive and rapid new method for early warning of TCM-induced cardiac toxicity and contributes technical support and scientific reference for improving diagnostic accuracy in herbal medicine safety assessment.</p><h3>Graphical Abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"192 10","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2025-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An electrochemical immunosensor based on HFABP for the early detection of drug-induced cardiac toxicity from traditional Chinese medicines\",\"authors\":\"Bolu Sun,&nbsp;Jiali Kang,&nbsp;Zixia Wang,&nbsp;Yuqiong Wu,&nbsp;Haiying He,&nbsp;Xinlan Wang,&nbsp;Xuanxiu Da,&nbsp;Miao Zhou,&nbsp;Ying Lv,&nbsp;Chenyu Qin,&nbsp;Xiangdong Wang,&nbsp;Lin Yang,&nbsp;Huajie Li,&nbsp;Hai Wang\",\"doi\":\"10.1007/s00604-025-07420-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>An electrochemical immunosensor was successfully developed for evaluating traditional Chinese medicine (TCM)-induced cardiac toxicity by immobilizing heart-type fatty acid-binding protein (HFABP)-specific antibodies on an electrode surface modified with chitosan (CS)-functionalized metal–organic framework ZIF-8 and gold nanoparticles (AuNPs). Leveraging the excellent biocompatibility of AuNPs, the excellent stability and high surface area of ZIF-8, along with the strong specific recognition capability of HFABP antibodies, the sensor demonstrated superior performance. Under optimized experimental conditions, it achieved an ultra-low detection limit of 7.09 × 10<sup>−2</sup> pg mL<sup>−1</sup> for HFABP, maintained excellent linearity in the range 1.57 × 10<sup>−2</sup> ~ 1.60 × 10<sup>1</sup> ng mL<sup>−1</sup>, and outperformed conventional ELISA methods in sensitivity when applied to TCM-induced cardiac toxicity models. The sensor also demonstrated excellent specificity, reproducibility, and stability. This research provides a sensitive and rapid new method for early warning of TCM-induced cardiac toxicity and contributes technical support and scientific reference for improving diagnostic accuracy in herbal medicine safety assessment.</p><h3>Graphical Abstract</h3>\\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>\",\"PeriodicalId\":705,\"journal\":{\"name\":\"Microchimica Acta\",\"volume\":\"192 10\",\"pages\":\"\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2025-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microchimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00604-025-07420-6\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-025-07420-6","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

通过将心脏型脂肪酸结合蛋白(HFABP)特异性抗体固定在壳聚糖(CS)功能化金属-有机骨架ZIF-8和金纳米颗粒(AuNPs)修饰的电极表面,成功研制了一种用于评价中药诱导的心脏毒性的电化学免疫传感器。利用aunp优异的生物相容性、ZIF-8优异的稳定性和高表面积,以及对HFABP抗体较强的特异性识别能力,该传感器表现出优越的性能。在优化的实验条件下,HFABP的超低检出限为7.09 × 10−2 pg mL−1,在1.57 × 10−2 ~ 1.60 × 101 ng mL−1范围内保持良好的线性关系,用于中药致心脏毒性模型的灵敏度优于传统ELISA方法。该传感器还表现出良好的特异性、重复性和稳定性。本研究为中药心脏毒性早期预警提供了一种灵敏、快速的新方法,为提高中药安全性评价的诊断准确性提供了技术支持和科学参考。图形抽象
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An electrochemical immunosensor based on HFABP for the early detection of drug-induced cardiac toxicity from traditional Chinese medicines

An electrochemical immunosensor was successfully developed for evaluating traditional Chinese medicine (TCM)-induced cardiac toxicity by immobilizing heart-type fatty acid-binding protein (HFABP)-specific antibodies on an electrode surface modified with chitosan (CS)-functionalized metal–organic framework ZIF-8 and gold nanoparticles (AuNPs). Leveraging the excellent biocompatibility of AuNPs, the excellent stability and high surface area of ZIF-8, along with the strong specific recognition capability of HFABP antibodies, the sensor demonstrated superior performance. Under optimized experimental conditions, it achieved an ultra-low detection limit of 7.09 × 10−2 pg mL−1 for HFABP, maintained excellent linearity in the range 1.57 × 10−2 ~ 1.60 × 101 ng mL−1, and outperformed conventional ELISA methods in sensitivity when applied to TCM-induced cardiac toxicity models. The sensor also demonstrated excellent specificity, reproducibility, and stability. This research provides a sensitive and rapid new method for early warning of TCM-induced cardiac toxicity and contributes technical support and scientific reference for improving diagnostic accuracy in herbal medicine safety assessment.

Graphical Abstract

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信