Xue Kong, Zimei Yu, Qinghua Sun, Yan Liu, Zheng-Zhi Yin
{"title":"基于分子印迹层的β-淀粉样蛋白42集成高效微生物传感器","authors":"Xue Kong, Zimei Yu, Qinghua Sun, Yan Liu, Zheng-Zhi Yin","doi":"10.1016/j.bioelechem.2025.109095","DOIUrl":null,"url":null,"abstract":"<div><div>Monitoring beta-amyloid<sub>1</sub><sub>–</sub><sub>42</sub> (Aβ<sub>42</sub>) is vital and challenging, which is a typical biomarker of Alzheimer's disease. Here, a novel electrochemical microbiosensor is developed to detect Aβ<sub>42</sub> on an acupuncture needle. Hemin is well known for its characteristics, including its ability to self-assemble on single-walled carbon nanotube (SWCNT), the molecular interaction with Aβ<sub>42</sub>, and the intrinsic electroactive signal. These properties are exploited to anchor and respond to Aβ<sub>42</sub> after integrating a molecularly imprinted surface polymer (SMIP). The SMIP layer of polydopamine/poly (ionic liquid) can be prepared by electropolymerization on an acupuncture needle microelectrode (ANME), which undergoes growth and formation of a polymeric structure around the anchored Aβ<sub>42</sub>. Interestingly, the imprinted cavities express a fluent signal of built-in hemin after eluting the templates, and show a highly selective and sensitive hindrance response for the recombined Aβ<sub>42</sub>. Under optimized conditions, the microbiosensor displays a linear range of 100 to 1 × 10<sup>10</sup> fM with a limit of detection of 0.05 fM. There are development and advances for the discipline of electroanalysis after comparing the technique and important indicators with the electrochemical biosensors reported of Aβ<sub>42</sub>. The microbiosensor also exhibited excellent selectivity, good stability, and reproducibility, which was effectively used to detect Aβ<sub>42</sub> in real spiked samples. The improved behavior of the developed microbiosensor can be attributed to its superficial highly matched imprinted cavities, built-in hemin label, and electronic barrier without signal of the nonimprinted surface to outside molecules. This microbiosensor has a scientific and reference value for directly sensing non-electroactive biomarkers, functionalizing microelectrodes, and electron transport cavities. It would also be amazing if this new microbiosensor could combine with the unclear and magical property of acupuncture in the treatment of neurological disorders.</div></div>","PeriodicalId":252,"journal":{"name":"Bioelectrochemistry","volume":"167 ","pages":"Article 109095"},"PeriodicalIF":4.5000,"publicationDate":"2025-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An integrative and efficient microbiosensor for β-amyloid42 based on a molecularly imprinted layer coordinating built-in hemin on the acupuncture needle\",\"authors\":\"Xue Kong, Zimei Yu, Qinghua Sun, Yan Liu, Zheng-Zhi Yin\",\"doi\":\"10.1016/j.bioelechem.2025.109095\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Monitoring beta-amyloid<sub>1</sub><sub>–</sub><sub>42</sub> (Aβ<sub>42</sub>) is vital and challenging, which is a typical biomarker of Alzheimer's disease. Here, a novel electrochemical microbiosensor is developed to detect Aβ<sub>42</sub> on an acupuncture needle. Hemin is well known for its characteristics, including its ability to self-assemble on single-walled carbon nanotube (SWCNT), the molecular interaction with Aβ<sub>42</sub>, and the intrinsic electroactive signal. These properties are exploited to anchor and respond to Aβ<sub>42</sub> after integrating a molecularly imprinted surface polymer (SMIP). The SMIP layer of polydopamine/poly (ionic liquid) can be prepared by electropolymerization on an acupuncture needle microelectrode (ANME), which undergoes growth and formation of a polymeric structure around the anchored Aβ<sub>42</sub>. Interestingly, the imprinted cavities express a fluent signal of built-in hemin after eluting the templates, and show a highly selective and sensitive hindrance response for the recombined Aβ<sub>42</sub>. Under optimized conditions, the microbiosensor displays a linear range of 100 to 1 × 10<sup>10</sup> fM with a limit of detection of 0.05 fM. There are development and advances for the discipline of electroanalysis after comparing the technique and important indicators with the electrochemical biosensors reported of Aβ<sub>42</sub>. The microbiosensor also exhibited excellent selectivity, good stability, and reproducibility, which was effectively used to detect Aβ<sub>42</sub> in real spiked samples. The improved behavior of the developed microbiosensor can be attributed to its superficial highly matched imprinted cavities, built-in hemin label, and electronic barrier without signal of the nonimprinted surface to outside molecules. This microbiosensor has a scientific and reference value for directly sensing non-electroactive biomarkers, functionalizing microelectrodes, and electron transport cavities. It would also be amazing if this new microbiosensor could combine with the unclear and magical property of acupuncture in the treatment of neurological disorders.</div></div>\",\"PeriodicalId\":252,\"journal\":{\"name\":\"Bioelectrochemistry\",\"volume\":\"167 \",\"pages\":\"Article 109095\"},\"PeriodicalIF\":4.5000,\"publicationDate\":\"2025-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioelectrochemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1567539425001987\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioelectrochemistry","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1567539425001987","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
An integrative and efficient microbiosensor for β-amyloid42 based on a molecularly imprinted layer coordinating built-in hemin on the acupuncture needle
Monitoring beta-amyloid1–42 (Aβ42) is vital and challenging, which is a typical biomarker of Alzheimer's disease. Here, a novel electrochemical microbiosensor is developed to detect Aβ42 on an acupuncture needle. Hemin is well known for its characteristics, including its ability to self-assemble on single-walled carbon nanotube (SWCNT), the molecular interaction with Aβ42, and the intrinsic electroactive signal. These properties are exploited to anchor and respond to Aβ42 after integrating a molecularly imprinted surface polymer (SMIP). The SMIP layer of polydopamine/poly (ionic liquid) can be prepared by electropolymerization on an acupuncture needle microelectrode (ANME), which undergoes growth and formation of a polymeric structure around the anchored Aβ42. Interestingly, the imprinted cavities express a fluent signal of built-in hemin after eluting the templates, and show a highly selective and sensitive hindrance response for the recombined Aβ42. Under optimized conditions, the microbiosensor displays a linear range of 100 to 1 × 1010 fM with a limit of detection of 0.05 fM. There are development and advances for the discipline of electroanalysis after comparing the technique and important indicators with the electrochemical biosensors reported of Aβ42. The microbiosensor also exhibited excellent selectivity, good stability, and reproducibility, which was effectively used to detect Aβ42 in real spiked samples. The improved behavior of the developed microbiosensor can be attributed to its superficial highly matched imprinted cavities, built-in hemin label, and electronic barrier without signal of the nonimprinted surface to outside molecules. This microbiosensor has a scientific and reference value for directly sensing non-electroactive biomarkers, functionalizing microelectrodes, and electron transport cavities. It would also be amazing if this new microbiosensor could combine with the unclear and magical property of acupuncture in the treatment of neurological disorders.
期刊介绍:
An International Journal Devoted to Electrochemical Aspects of Biology and Biological Aspects of Electrochemistry
Bioelectrochemistry is an international journal devoted to electrochemical principles in biology and biological aspects of electrochemistry. It publishes experimental and theoretical papers dealing with the electrochemical aspects of:
• Electrified interfaces (electric double layers, adsorption, electron transfer, protein electrochemistry, basic principles of biosensors, biosensor interfaces and bio-nanosensor design and construction.
• Electric and magnetic field effects (field-dependent processes, field interactions with molecules, intramolecular field effects, sensory systems for electric and magnetic fields, molecular and cellular mechanisms)
• Bioenergetics and signal transduction (energy conversion, photosynthetic and visual membranes)
• Biomembranes and model membranes (thermodynamics and mechanics, membrane transport, electroporation, fusion and insertion)
• Electrochemical applications in medicine and biotechnology (drug delivery and gene transfer to cells and tissues, iontophoresis, skin electroporation, injury and repair).
• Organization and use of arrays in-vitro and in-vivo, including as part of feedback control.
• Electrochemical interrogation of biofilms as generated by microorganisms and tissue reaction associated with medical implants.