Muhammad Qamar;Kamil Yavuz Kapusuz;Lawrence Carslake;Tian-Hong Loh;Mohamed A. Thaha;Akram Alomainy
{"title":"用于高数据速率无线胶囊内窥镜的超紧凑相机集成深度植入双端口MIMO天线","authors":"Muhammad Qamar;Kamil Yavuz Kapusuz;Lawrence Carslake;Tian-Hong Loh;Mohamed A. Thaha;Akram Alomainy","doi":"10.1109/JERM.2024.3501385","DOIUrl":null,"url":null,"abstract":"This study proposes a novel high-performance, two-element camera-integrated antenna array for the [401-406] MHz medical device radio communications service (MedRadio) band. The array is designed for integration inside a capsule to establish a stable, high data-rate multiple-input multiple-output (MIMO) wireless communication link for wireless endoscopy. The compact antenna (<inline-formula><tex-math>$\\pi \\times$</tex-math></inline-formula> 1.125 ×1.49 mm<inline-formula><tex-math>$^{3}$</tex-math></inline-formula>) uses stacked meandered resonators, nestled within an annular ring-shaped planar substrate, offering over 7 MHz bandwidth and 41 dB isolation. It achieves a 78 Mbps data rate over 1.6 m in muscle tissue with a specific absorption rate of 2 W/kg at 20 mW power. Measurements show an ECC below 0.001, diversity gain over 9.99 dB, and a channel capacity of 10 bps/Hz at 20 dB SNR. To the best of our knowledge, this is the first dual-camera-integrated MIMO antenna system for the [401-406] MHz MedRadio band tested in an implantable device.","PeriodicalId":29955,"journal":{"name":"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology","volume":"9 3","pages":"293-301"},"PeriodicalIF":3.2000,"publicationDate":"2024-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultra-Compact Camera-Integrated Deep-Implanted Two-Port MIMO Antenna for High-Data-Rate Wireless Capsule Endoscopy\",\"authors\":\"Muhammad Qamar;Kamil Yavuz Kapusuz;Lawrence Carslake;Tian-Hong Loh;Mohamed A. Thaha;Akram Alomainy\",\"doi\":\"10.1109/JERM.2024.3501385\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study proposes a novel high-performance, two-element camera-integrated antenna array for the [401-406] MHz medical device radio communications service (MedRadio) band. The array is designed for integration inside a capsule to establish a stable, high data-rate multiple-input multiple-output (MIMO) wireless communication link for wireless endoscopy. The compact antenna (<inline-formula><tex-math>$\\\\pi \\\\times$</tex-math></inline-formula> 1.125 ×1.49 mm<inline-formula><tex-math>$^{3}$</tex-math></inline-formula>) uses stacked meandered resonators, nestled within an annular ring-shaped planar substrate, offering over 7 MHz bandwidth and 41 dB isolation. It achieves a 78 Mbps data rate over 1.6 m in muscle tissue with a specific absorption rate of 2 W/kg at 20 mW power. Measurements show an ECC below 0.001, diversity gain over 9.99 dB, and a channel capacity of 10 bps/Hz at 20 dB SNR. To the best of our knowledge, this is the first dual-camera-integrated MIMO antenna system for the [401-406] MHz MedRadio band tested in an implantable device.\",\"PeriodicalId\":29955,\"journal\":{\"name\":\"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology\",\"volume\":\"9 3\",\"pages\":\"293-301\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10777505/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10777505/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Ultra-Compact Camera-Integrated Deep-Implanted Two-Port MIMO Antenna for High-Data-Rate Wireless Capsule Endoscopy
This study proposes a novel high-performance, two-element camera-integrated antenna array for the [401-406] MHz medical device radio communications service (MedRadio) band. The array is designed for integration inside a capsule to establish a stable, high data-rate multiple-input multiple-output (MIMO) wireless communication link for wireless endoscopy. The compact antenna ($\pi \times$ 1.125 ×1.49 mm$^{3}$) uses stacked meandered resonators, nestled within an annular ring-shaped planar substrate, offering over 7 MHz bandwidth and 41 dB isolation. It achieves a 78 Mbps data rate over 1.6 m in muscle tissue with a specific absorption rate of 2 W/kg at 20 mW power. Measurements show an ECC below 0.001, diversity gain over 9.99 dB, and a channel capacity of 10 bps/Hz at 20 dB SNR. To the best of our knowledge, this is the first dual-camera-integrated MIMO antenna system for the [401-406] MHz MedRadio band tested in an implantable device.