被动环境中子剂量计的称重选择:padc、tld、osld和裂变径迹探测器的比较研究

IF 2.2 3区 物理与天体物理 Q2 NUCLEAR SCIENCE & TECHNOLOGY
Lily Bossin, Jeppe Brage Christensen, Federico Alejandro Geser, Malgorzata Kasprzak, Sabine Mayer, Malgorzata Sliz, Alberto Stabilini, Eduardo Gardenali Yukihara
{"title":"被动环境中子剂量计的称重选择:padc、tld、osld和裂变径迹探测器的比较研究","authors":"Lily Bossin,&nbsp;Jeppe Brage Christensen,&nbsp;Federico Alejandro Geser,&nbsp;Malgorzata Kasprzak,&nbsp;Sabine Mayer,&nbsp;Malgorzata Sliz,&nbsp;Alberto Stabilini,&nbsp;Eduardo Gardenali Yukihara","doi":"10.1016/j.radmeas.2025.107504","DOIUrl":null,"url":null,"abstract":"<div><div>This study aims to evaluate the potential of polyallyl diglycol carbonate (PADC) detectors, coupled with <span><math><msup><mrow></mrow><mrow><mn>6</mn></mrow></msup></math></span>LiF converters, for passive environmental neutron dosimetry. Their performance is compared against three other methods, fission track detectors, thermoluminescent detectors (TLDs), and optically stimulated luminescence detectors (OSLDs), to determine their viability for passive routine neutron monitoring in environmental settings.</div><div>The four detector types investigated (PADCs, fission tracks, TLDs and OSLDs) were placed in a moderator sphere and exposed to an AmBe neutron field. The measurements evaluated the dose response, measurement range, and precision of each system.</div><div>Results confirm that the advantage of the track detectors (PADC or fission track) is their gamma insensitivity: the TLD and OSLD methods require the combination of neutron-sensitive with neutron-insensitive detectors, as both are gamma-sensitive. This translated into a detection limit <span><math><mrow><msup><mrow><mi>H</mi></mrow><mrow><mo>∗</mo></mrow></msup><mrow><mo>(</mo><mn>10</mn><mo>)</mo></mrow></mrow></math></span>=6<!--> <!-->μ<!--> <!-->Sv for PADC detectors coupled with <span><math><msup><mrow></mrow><mrow><mn>6</mn></mrow></msup></math></span>LiF converters, comparable to that of fission track detectors (3<!--> <!-->μ<!--> <!-->Sv). In contrast, the gamma-sensitive luminescence systems showed a detection limit of 10<!--> <!-->μ<!--> <!-->Sv for the TLDs and 180<!--> <!-->μ<!--> <!-->Sv for the OSLDs under AmBe neutron irradiations. This worsens under simulated environmental conditions, where a significant gamma contribution is expected, as demonstrated by a test where mixed gamma/neutron irradiation was used.</div><div>These results indicate the potential of the PADC coupled with a <span><math><msup><mrow></mrow><mrow><mn>6</mn></mrow></msup></math></span>LiF converter system as a robust alternative to fission track detectors for passive environmental neutron dosimetry.</div></div>","PeriodicalId":21055,"journal":{"name":"Radiation Measurements","volume":"188 ","pages":"Article 107504"},"PeriodicalIF":2.2000,"publicationDate":"2025-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Weighing options for passive environmental neutron dosimetry: A comparative study of PADCs, TLDs, OSLDs, and fission track detectors\",\"authors\":\"Lily Bossin,&nbsp;Jeppe Brage Christensen,&nbsp;Federico Alejandro Geser,&nbsp;Malgorzata Kasprzak,&nbsp;Sabine Mayer,&nbsp;Malgorzata Sliz,&nbsp;Alberto Stabilini,&nbsp;Eduardo Gardenali Yukihara\",\"doi\":\"10.1016/j.radmeas.2025.107504\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This study aims to evaluate the potential of polyallyl diglycol carbonate (PADC) detectors, coupled with <span><math><msup><mrow></mrow><mrow><mn>6</mn></mrow></msup></math></span>LiF converters, for passive environmental neutron dosimetry. Their performance is compared against three other methods, fission track detectors, thermoluminescent detectors (TLDs), and optically stimulated luminescence detectors (OSLDs), to determine their viability for passive routine neutron monitoring in environmental settings.</div><div>The four detector types investigated (PADCs, fission tracks, TLDs and OSLDs) were placed in a moderator sphere and exposed to an AmBe neutron field. The measurements evaluated the dose response, measurement range, and precision of each system.</div><div>Results confirm that the advantage of the track detectors (PADC or fission track) is their gamma insensitivity: the TLD and OSLD methods require the combination of neutron-sensitive with neutron-insensitive detectors, as both are gamma-sensitive. This translated into a detection limit <span><math><mrow><msup><mrow><mi>H</mi></mrow><mrow><mo>∗</mo></mrow></msup><mrow><mo>(</mo><mn>10</mn><mo>)</mo></mrow></mrow></math></span>=6<!--> <!-->μ<!--> <!-->Sv for PADC detectors coupled with <span><math><msup><mrow></mrow><mrow><mn>6</mn></mrow></msup></math></span>LiF converters, comparable to that of fission track detectors (3<!--> <!-->μ<!--> <!-->Sv). In contrast, the gamma-sensitive luminescence systems showed a detection limit of 10<!--> <!-->μ<!--> <!-->Sv for the TLDs and 180<!--> <!-->μ<!--> <!-->Sv for the OSLDs under AmBe neutron irradiations. This worsens under simulated environmental conditions, where a significant gamma contribution is expected, as demonstrated by a test where mixed gamma/neutron irradiation was used.</div><div>These results indicate the potential of the PADC coupled with a <span><math><msup><mrow></mrow><mrow><mn>6</mn></mrow></msup></math></span>LiF converter system as a robust alternative to fission track detectors for passive environmental neutron dosimetry.</div></div>\",\"PeriodicalId\":21055,\"journal\":{\"name\":\"Radiation Measurements\",\"volume\":\"188 \",\"pages\":\"Article 107504\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation Measurements\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1350448725001337\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Measurements","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350448725001337","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在评估PADC(聚烯丙基二甘醇碳酸酯)探测器和6liff转换器在被动环境中子剂量测定中的应用潜力。将它们的性能与其他三种方法(裂变径迹探测器、热释光探测器(tld)和光激发发光探测器(osld))进行比较,以确定它们在环境设置中被动常规中子监测的可行性。所研究的四种探测器类型(padc、裂变径迹、TLDs和osld)被放置在慢化剂球中并暴露在AmBe中子场中。测量评估了每个系统的剂量反应、测量范围和精度。结果证实了径迹探测器(PADC或裂变径迹)的优点是它们的伽马不敏感:TLD和OSLD方法需要中子敏感和中子不敏感探测器的结合,因为两者都是伽马敏感的。这意味着与6LiF转换器耦合的PADC探测器的检测极限H * (10)=6 μ Sv,与裂变径迹探测器的检测极限(3 μ Sv)相当。相比之下,在AmBe中子辐照下,伽马敏感发光系统对TLDs的检测限为10 μ Sv,对OSLDs的检测限为180 μ Sv。在模拟环境条件下,这种情况会恶化,因为在模拟环境条件下,使用混合伽马/中子辐照的测试表明,伽马对辐射的贡献很大。这些结果表明,PADC与6LiF变换器系统耦合的潜力,作为被动环境中子剂量测定的裂变径迹探测器的强大替代品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Weighing options for passive environmental neutron dosimetry: A comparative study of PADCs, TLDs, OSLDs, and fission track detectors
This study aims to evaluate the potential of polyallyl diglycol carbonate (PADC) detectors, coupled with 6LiF converters, for passive environmental neutron dosimetry. Their performance is compared against three other methods, fission track detectors, thermoluminescent detectors (TLDs), and optically stimulated luminescence detectors (OSLDs), to determine their viability for passive routine neutron monitoring in environmental settings.
The four detector types investigated (PADCs, fission tracks, TLDs and OSLDs) were placed in a moderator sphere and exposed to an AmBe neutron field. The measurements evaluated the dose response, measurement range, and precision of each system.
Results confirm that the advantage of the track detectors (PADC or fission track) is their gamma insensitivity: the TLD and OSLD methods require the combination of neutron-sensitive with neutron-insensitive detectors, as both are gamma-sensitive. This translated into a detection limit H(10)=6 μ Sv for PADC detectors coupled with 6LiF converters, comparable to that of fission track detectors (3 μ Sv). In contrast, the gamma-sensitive luminescence systems showed a detection limit of 10 μ Sv for the TLDs and 180 μ Sv for the OSLDs under AmBe neutron irradiations. This worsens under simulated environmental conditions, where a significant gamma contribution is expected, as demonstrated by a test where mixed gamma/neutron irradiation was used.
These results indicate the potential of the PADC coupled with a 6LiF converter system as a robust alternative to fission track detectors for passive environmental neutron dosimetry.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiation Measurements
Radiation Measurements 工程技术-核科学技术
CiteScore
4.10
自引率
20.00%
发文量
116
审稿时长
48 days
期刊介绍: The journal seeks to publish papers that present advances in the following areas: spontaneous and stimulated luminescence (including scintillating materials, thermoluminescence, and optically stimulated luminescence); electron spin resonance of natural and synthetic materials; the physics, design and performance of radiation measurements (including computational modelling such as electronic transport simulations); the novel basic aspects of radiation measurement in medical physics. Studies of energy-transfer phenomena, track physics and microdosimetry are also of interest to the journal. Applications relevant to the journal, particularly where they present novel detection techniques, novel analytical approaches or novel materials, include: personal dosimetry (including dosimetric quantities, active/electronic and passive monitoring techniques for photon, neutron and charged-particle exposures); environmental dosimetry (including methodological advances and predictive models related to radon, but generally excluding local survey results of radon where the main aim is to establish the radiation risk to populations); cosmic and high-energy radiation measurements (including dosimetry, space radiation effects, and single event upsets); dosimetry-based archaeological and Quaternary dating; dosimetry-based approaches to thermochronometry; accident and retrospective dosimetry (including activation detectors), and dosimetry and measurements related to medical applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信