Mohamed E. Zayed , Kashif Irshad , Shafiqur Rehman , A.E. Kabeel , Mohammed El Hadi Attia , A.S. Abdelrazik , Abdelkrim Khelifa , Mohamed Abdelgaied , Mohamed A. Mohandes , Salem Algarni , Talal Alqahtani
{"title":"一个改进的翅片太阳能空气集热器的性能评估,由一个智能开关盖热辅助恒定的出口热风温度:数值研究","authors":"Mohamed E. Zayed , Kashif Irshad , Shafiqur Rehman , A.E. Kabeel , Mohammed El Hadi Attia , A.S. Abdelrazik , Abdelkrim Khelifa , Mohamed Abdelgaied , Mohamed A. Mohandes , Salem Algarni , Talal Alqahtani","doi":"10.1016/j.nexus.2025.100529","DOIUrl":null,"url":null,"abstract":"<div><div>This study introduces a modified finned plate solar air heater (FPSAH) combined with a low-cost smart-switchable cover (SSC) for constant outlet hot air temperature. The SSC is adapted as a sun blackout shield cover with a controllable curtain roller blind which is flexible to automatically and partially shade the glazing coverage. The main objective is to manage the falling solar energy transmitted through the glazing coverage to permanently facilitate a constant outlet hot air temperature throughout the daytime. The FPSAH-SSC is studied through CFD simulations under solar irradiation values changing from 600 to 1000 W/m<sup>2</sup> at a constant airflow rate of 0.60 kg/min. A series of simulations is performed to determine the optimal shading length of the SSC corresponding to each solar irradiation value to provide a constant outlet hot air temperature of 50 °C. Moreover, thermo-economic analyses are conducted on the proposed system to evaluate the heating power, outlet hot air temperature, average Nusselt number, energy efficiency, and cost of 1.0 kW of thermal heat. The results show that the optimal shading lengths, corresponding to solar irradiation of 600, 700, 800, 900, and 1000 W/m<sup>2</sup>, are determined to be 0.0, 4.0, 20, 30, and 40 cm, respectively. This in consequence results in a controlled outlet hot air temperature from the proposed FPSAH-SSC of 48.08, 49.85, 49.83, 50.11, and 49.84 ° °C, capable of decreasing the hot air temperatures by 8.95 %, 14.57 %, 18.7 %, and 24.44 %, respectively, compared to the case without using an SSC. Moreover, the energy efficiency reaches up to 40.62 %, while the cost of 1 kW of thermal heat is estimated at 0.0098 $/kWh, respectively.</div></div>","PeriodicalId":93548,"journal":{"name":"Energy nexus","volume":"19 ","pages":"Article 100529"},"PeriodicalIF":9.5000,"publicationDate":"2025-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance appraisal of a modified finned solar air collector thermally assisted by a smart-switchable cover for constant outlet hot air temperature: Numerical investigation\",\"authors\":\"Mohamed E. Zayed , Kashif Irshad , Shafiqur Rehman , A.E. Kabeel , Mohammed El Hadi Attia , A.S. Abdelrazik , Abdelkrim Khelifa , Mohamed Abdelgaied , Mohamed A. Mohandes , Salem Algarni , Talal Alqahtani\",\"doi\":\"10.1016/j.nexus.2025.100529\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This study introduces a modified finned plate solar air heater (FPSAH) combined with a low-cost smart-switchable cover (SSC) for constant outlet hot air temperature. The SSC is adapted as a sun blackout shield cover with a controllable curtain roller blind which is flexible to automatically and partially shade the glazing coverage. The main objective is to manage the falling solar energy transmitted through the glazing coverage to permanently facilitate a constant outlet hot air temperature throughout the daytime. The FPSAH-SSC is studied through CFD simulations under solar irradiation values changing from 600 to 1000 W/m<sup>2</sup> at a constant airflow rate of 0.60 kg/min. A series of simulations is performed to determine the optimal shading length of the SSC corresponding to each solar irradiation value to provide a constant outlet hot air temperature of 50 °C. Moreover, thermo-economic analyses are conducted on the proposed system to evaluate the heating power, outlet hot air temperature, average Nusselt number, energy efficiency, and cost of 1.0 kW of thermal heat. The results show that the optimal shading lengths, corresponding to solar irradiation of 600, 700, 800, 900, and 1000 W/m<sup>2</sup>, are determined to be 0.0, 4.0, 20, 30, and 40 cm, respectively. This in consequence results in a controlled outlet hot air temperature from the proposed FPSAH-SSC of 48.08, 49.85, 49.83, 50.11, and 49.84 ° °C, capable of decreasing the hot air temperatures by 8.95 %, 14.57 %, 18.7 %, and 24.44 %, respectively, compared to the case without using an SSC. Moreover, the energy efficiency reaches up to 40.62 %, while the cost of 1 kW of thermal heat is estimated at 0.0098 $/kWh, respectively.</div></div>\",\"PeriodicalId\":93548,\"journal\":{\"name\":\"Energy nexus\",\"volume\":\"19 \",\"pages\":\"Article 100529\"},\"PeriodicalIF\":9.5000,\"publicationDate\":\"2025-08-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy nexus\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S277242712500169X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy nexus","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S277242712500169X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Performance appraisal of a modified finned solar air collector thermally assisted by a smart-switchable cover for constant outlet hot air temperature: Numerical investigation
This study introduces a modified finned plate solar air heater (FPSAH) combined with a low-cost smart-switchable cover (SSC) for constant outlet hot air temperature. The SSC is adapted as a sun blackout shield cover with a controllable curtain roller blind which is flexible to automatically and partially shade the glazing coverage. The main objective is to manage the falling solar energy transmitted through the glazing coverage to permanently facilitate a constant outlet hot air temperature throughout the daytime. The FPSAH-SSC is studied through CFD simulations under solar irradiation values changing from 600 to 1000 W/m2 at a constant airflow rate of 0.60 kg/min. A series of simulations is performed to determine the optimal shading length of the SSC corresponding to each solar irradiation value to provide a constant outlet hot air temperature of 50 °C. Moreover, thermo-economic analyses are conducted on the proposed system to evaluate the heating power, outlet hot air temperature, average Nusselt number, energy efficiency, and cost of 1.0 kW of thermal heat. The results show that the optimal shading lengths, corresponding to solar irradiation of 600, 700, 800, 900, and 1000 W/m2, are determined to be 0.0, 4.0, 20, 30, and 40 cm, respectively. This in consequence results in a controlled outlet hot air temperature from the proposed FPSAH-SSC of 48.08, 49.85, 49.83, 50.11, and 49.84 ° °C, capable of decreasing the hot air temperatures by 8.95 %, 14.57 %, 18.7 %, and 24.44 %, respectively, compared to the case without using an SSC. Moreover, the energy efficiency reaches up to 40.62 %, while the cost of 1 kW of thermal heat is estimated at 0.0098 $/kWh, respectively.
Energy nexusEnergy (General), Ecological Modelling, Renewable Energy, Sustainability and the Environment, Water Science and Technology, Agricultural and Biological Sciences (General)