下颌覆盖义齿一体式钛锆微型种植体根尖骨折的前瞻性3年随访

IF 4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Cláudio Rodrigues Leles, Thalita Fernandes Fleury Curado, José Luiz Rodrigues Leles, Nádia Lago Costa, Manrique Fonseca, Martin Schimmel, Gerald McKenna
{"title":"下颌覆盖义齿一体式钛锆微型种植体根尖骨折的前瞻性3年随访","authors":"Cláudio Rodrigues Leles,&nbsp;Thalita Fernandes Fleury Curado,&nbsp;José Luiz Rodrigues Leles,&nbsp;Nádia Lago Costa,&nbsp;Manrique Fonseca,&nbsp;Martin Schimmel,&nbsp;Gerald McKenna","doi":"10.1111/cid.70084","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>To assess the 3-year clinic-radiographic features and risk factors for apical fracture of mini-implants for mandibular overdentures.</p>\n </section>\n \n <section>\n \n <h3> Material and Methods</h3>\n \n <p>Participants in a clinical trial (<i>n</i> = 74) were assessed for post-insertion identification of apical fractures of one-piece titanium–zirconium mini-implants (Straumann Mini-Implant System). Fractures were identified during implant insertion or in follow-up imaging exams. Cases were clinically and radiographically monitored up to the 3-year follow-up.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Five implants in five patients had apical fractures (1.69% of the 296 inserted implants). No clinical signs of peri-implant complications were found, and overall treatment outcomes were positive for all patients. Satisfactory osseointegration was achieved, and no evidence of periapical pathology was noted on panoramic radiographs. The patients were notified about the apical implant fracture at the time of the surgery, and during follow-up appointments, they were reassured about the absence of further complications in the long term. It was hypothesized that the increased risk of fracture was associated with high insertion torques (around 80 N cm) and implant insertion in areas where the tip engages into a hard basal cortical bone (Types I–II) with an inclined cortical surface in the lingual aspect of the alveolar bone.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The incidence of apical fracture was low and did not result in any clinically relevant complications and may be detected during the surgery or in follow-up radiographs. Although the intraosseous implant tip fragment may not be of major concern, additional caution to prevent excessive insertion torque and to avoid anatomical regions of higher risk may be advisable.</p>\n </section>\n </div>","PeriodicalId":50679,"journal":{"name":"Clinical Implant Dentistry and Related Research","volume":"27 4","pages":""},"PeriodicalIF":4.0000,"publicationDate":"2025-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cid.70084","citationCount":"0","resultStr":"{\"title\":\"Apical Fracture of One-Piece Titanium–Zirconium Mini-Implant for Mandibular Overdenture: A Prospective 3-Year Follow-Up\",\"authors\":\"Cláudio Rodrigues Leles,&nbsp;Thalita Fernandes Fleury Curado,&nbsp;José Luiz Rodrigues Leles,&nbsp;Nádia Lago Costa,&nbsp;Manrique Fonseca,&nbsp;Martin Schimmel,&nbsp;Gerald McKenna\",\"doi\":\"10.1111/cid.70084\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objectives</h3>\\n \\n <p>To assess the 3-year clinic-radiographic features and risk factors for apical fracture of mini-implants for mandibular overdentures.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Material and Methods</h3>\\n \\n <p>Participants in a clinical trial (<i>n</i> = 74) were assessed for post-insertion identification of apical fractures of one-piece titanium–zirconium mini-implants (Straumann Mini-Implant System). Fractures were identified during implant insertion or in follow-up imaging exams. Cases were clinically and radiographically monitored up to the 3-year follow-up.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Five implants in five patients had apical fractures (1.69% of the 296 inserted implants). No clinical signs of peri-implant complications were found, and overall treatment outcomes were positive for all patients. Satisfactory osseointegration was achieved, and no evidence of periapical pathology was noted on panoramic radiographs. The patients were notified about the apical implant fracture at the time of the surgery, and during follow-up appointments, they were reassured about the absence of further complications in the long term. It was hypothesized that the increased risk of fracture was associated with high insertion torques (around 80 N cm) and implant insertion in areas where the tip engages into a hard basal cortical bone (Types I–II) with an inclined cortical surface in the lingual aspect of the alveolar bone.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The incidence of apical fracture was low and did not result in any clinically relevant complications and may be detected during the surgery or in follow-up radiographs. Although the intraosseous implant tip fragment may not be of major concern, additional caution to prevent excessive insertion torque and to avoid anatomical regions of higher risk may be advisable.</p>\\n </section>\\n </div>\",\"PeriodicalId\":50679,\"journal\":{\"name\":\"Clinical Implant Dentistry and Related Research\",\"volume\":\"27 4\",\"pages\":\"\"},\"PeriodicalIF\":4.0000,\"publicationDate\":\"2025-08-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cid.70084\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Implant Dentistry and Related Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/cid.70084\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Implant Dentistry and Related Research","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cid.70084","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的探讨下颌覆盖义齿微型种植体根尖骨折的3年临床影像学特征及危险因素。材料和方法在一项临床试验中,对74名参与者进行了评估,以确定一体式钛-锆微型种植体(Straumann微型种植体系统)植入后的根尖骨折。骨折是在植入或后续影像学检查中发现的。对病例进行临床和影像学监测,直至3年随访。结果5例患者有5颗种植体发生根尖骨折,占296颗种植体的1.69%。未发现种植体周围并发症的临床体征,所有患者的总体治疗结果均为阳性。获得了令人满意的骨融合,在全景x线片上没有发现根尖周围病理的证据。患者在手术时被告知根尖种植体骨折,在随访期间,他们被保证在长期内没有进一步的并发症。据推测,骨折风险的增加与高插入扭矩(约80 N厘米)和种植体插入尖端与坚硬的基底皮质骨(I-II型)接合的区域有关,该区域在牙槽骨舌侧有倾斜的皮质表面。结论根尖骨折发生率低,无临床并发症,可在手术或随访x线片中发现。虽然骨内植入物尖端碎片可能不是主要问题,但建议注意防止过大的插入扭矩和避免解剖区域的高风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Apical Fracture of One-Piece Titanium–Zirconium Mini-Implant for Mandibular Overdenture: A Prospective 3-Year Follow-Up

Apical Fracture of One-Piece Titanium–Zirconium Mini-Implant for Mandibular Overdenture: A Prospective 3-Year Follow-Up

Objectives

To assess the 3-year clinic-radiographic features and risk factors for apical fracture of mini-implants for mandibular overdentures.

Material and Methods

Participants in a clinical trial (n = 74) were assessed for post-insertion identification of apical fractures of one-piece titanium–zirconium mini-implants (Straumann Mini-Implant System). Fractures were identified during implant insertion or in follow-up imaging exams. Cases were clinically and radiographically monitored up to the 3-year follow-up.

Results

Five implants in five patients had apical fractures (1.69% of the 296 inserted implants). No clinical signs of peri-implant complications were found, and overall treatment outcomes were positive for all patients. Satisfactory osseointegration was achieved, and no evidence of periapical pathology was noted on panoramic radiographs. The patients were notified about the apical implant fracture at the time of the surgery, and during follow-up appointments, they were reassured about the absence of further complications in the long term. It was hypothesized that the increased risk of fracture was associated with high insertion torques (around 80 N cm) and implant insertion in areas where the tip engages into a hard basal cortical bone (Types I–II) with an inclined cortical surface in the lingual aspect of the alveolar bone.

Conclusions

The incidence of apical fracture was low and did not result in any clinically relevant complications and may be detected during the surgery or in follow-up radiographs. Although the intraosseous implant tip fragment may not be of major concern, additional caution to prevent excessive insertion torque and to avoid anatomical regions of higher risk may be advisable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.00
自引率
13.90%
发文量
103
审稿时长
4-8 weeks
期刊介绍: The goal of Clinical Implant Dentistry and Related Research is to advance the scientific and technical aspects relating to dental implants and related scientific subjects. Dissemination of new and evolving information related to dental implants and the related science is the primary goal of our journal. The range of topics covered by the journals will include but be not limited to: New scientific developments relating to bone Implant surfaces and their relationship to the surrounding tissues Computer aided implant designs Computer aided prosthetic designs Immediate implant loading Immediate implant placement Materials relating to bone induction and conduction New surgical methods relating to implant placement New materials and methods relating to implant restorations Methods for determining implant stability A primary focus of the journal is publication of evidenced based articles evaluating to new dental implants, techniques and multicenter studies evaluating these treatments. In addition basic science research relating to wound healing and osseointegration will be an important focus for the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信