3d打印修复聚合物的机械和热性能的比较评估:树脂类型,打印机技术和后固化时间的影响

IF 3.5 2区 医学 Q2 ENGINEERING, BIOMEDICAL
Nathalia S. Finck , May Anny A. Fraga , Américo B. Correr , Tonny A. Moreira , Cleocir J. Dalmaschio , Vitor O. Ramagem , Rafael R. Moraes
{"title":"3d打印修复聚合物的机械和热性能的比较评估:树脂类型,打印机技术和后固化时间的影响","authors":"Nathalia S. Finck ,&nbsp;May Anny A. Fraga ,&nbsp;Américo B. Correr ,&nbsp;Tonny A. Moreira ,&nbsp;Cleocir J. Dalmaschio ,&nbsp;Vitor O. Ramagem ,&nbsp;Rafael R. Moraes","doi":"10.1016/j.jmbbm.2025.107166","DOIUrl":null,"url":null,"abstract":"<div><div>This study evaluated how resin type, printer technology, and post-curing time influence the mechanical and thermal properties of 3D-printed polymers for dental restorations. Bar-shaped specimens were printed with digital light processing (DLP) and liquid crystal display (LCD) printers using provisional and long-term resins. The post-curing times tested were 5 and 30 min. Response variables (n = 10) included fracture toughness (K<sub>IC</sub>, MPa√m), Knoop microhardness (kgf/mm<sup>2</sup>), and degree of C=C conversion (%DC). Thermal analyses were carried out via differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). Data were analyzed via three-way ANOVA (α = 0.05). Compared with the long-term resin, the provisional resin generally presented a superior K<sub>IC</sub>. The 30-min the post-curing time was linked to an increase in K<sub>IC</sub> in most conditions. No differences in microhardness were detected across any group. The long-term resin generally had a greater DC, and the DC was greater for the 30-min post-curing time than for the 5-min time for the provisional resin printed by the DLP printer. Longer post-curing times resulted in more complete curing of the resins. DSC and DMA analyses revealed that the 30 min post-curing time enhanced the thermal stability of both provisional and long-term resins, indicating more homogeneous polymer network formation with reduced residual monomers. The printer type had a minor effect on the performance of the restorative polymers. In conclusion, the resin material is key for 3D-printed dental restoratives, and longer curing times improved their mechanical and thermal properties.</div></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"172 ","pages":"Article 107166"},"PeriodicalIF":3.5000,"publicationDate":"2025-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative evaluation of mechanical and thermal properties of 3D-printed restorative polymers: Effects of resin type, printer technology, and post-curing time\",\"authors\":\"Nathalia S. Finck ,&nbsp;May Anny A. Fraga ,&nbsp;Américo B. Correr ,&nbsp;Tonny A. Moreira ,&nbsp;Cleocir J. Dalmaschio ,&nbsp;Vitor O. Ramagem ,&nbsp;Rafael R. Moraes\",\"doi\":\"10.1016/j.jmbbm.2025.107166\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This study evaluated how resin type, printer technology, and post-curing time influence the mechanical and thermal properties of 3D-printed polymers for dental restorations. Bar-shaped specimens were printed with digital light processing (DLP) and liquid crystal display (LCD) printers using provisional and long-term resins. The post-curing times tested were 5 and 30 min. Response variables (n = 10) included fracture toughness (K<sub>IC</sub>, MPa√m), Knoop microhardness (kgf/mm<sup>2</sup>), and degree of C=C conversion (%DC). Thermal analyses were carried out via differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). Data were analyzed via three-way ANOVA (α = 0.05). Compared with the long-term resin, the provisional resin generally presented a superior K<sub>IC</sub>. The 30-min the post-curing time was linked to an increase in K<sub>IC</sub> in most conditions. No differences in microhardness were detected across any group. The long-term resin generally had a greater DC, and the DC was greater for the 30-min post-curing time than for the 5-min time for the provisional resin printed by the DLP printer. Longer post-curing times resulted in more complete curing of the resins. DSC and DMA analyses revealed that the 30 min post-curing time enhanced the thermal stability of both provisional and long-term resins, indicating more homogeneous polymer network formation with reduced residual monomers. The printer type had a minor effect on the performance of the restorative polymers. In conclusion, the resin material is key for 3D-printed dental restoratives, and longer curing times improved their mechanical and thermal properties.</div></div>\",\"PeriodicalId\":380,\"journal\":{\"name\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"volume\":\"172 \",\"pages\":\"Article 107166\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2025-08-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1751616125002826\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616125002826","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究评估了树脂类型、打印机技术和后固化时间如何影响用于牙科修复的3d打印聚合物的机械和热性能。采用临时树脂和长效树脂,用数字光处理(DLP)和液晶显示(LCD)打印机打印条形标本。响应变量(n = 10)包括断裂韧性(KIC, MPa√m)、Knoop显微硬度(kgf/mm2)和C=C转换度(%DC)。热分析通过差示扫描量热法(DSC)和动态力学分析(DMA)进行。数据采用三因素方差分析(α = 0.05)。与长期树脂相比,临时树脂普遍表现出较好的KIC。在大多数情况下,固化后30分钟的时间与KIC的增加有关。各组间显微硬度均无差异。长期树脂通常具有较大的DC,并且固化后30分钟的DC大于DLP打印机打印的临时树脂的5分钟DC。固化后时间越长,树脂固化越彻底。DSC和DMA分析显示,30分钟后固化时间增强了临时和长期树脂的热稳定性,表明聚合物网络形成更加均匀,残留单体减少。打印机类型对修复聚合物的性能影响较小。总之,树脂材料是3d打印牙科修复体的关键,较长的固化时间改善了它们的机械和热性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative evaluation of mechanical and thermal properties of 3D-printed restorative polymers: Effects of resin type, printer technology, and post-curing time
This study evaluated how resin type, printer technology, and post-curing time influence the mechanical and thermal properties of 3D-printed polymers for dental restorations. Bar-shaped specimens were printed with digital light processing (DLP) and liquid crystal display (LCD) printers using provisional and long-term resins. The post-curing times tested were 5 and 30 min. Response variables (n = 10) included fracture toughness (KIC, MPa√m), Knoop microhardness (kgf/mm2), and degree of C=C conversion (%DC). Thermal analyses were carried out via differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). Data were analyzed via three-way ANOVA (α = 0.05). Compared with the long-term resin, the provisional resin generally presented a superior KIC. The 30-min the post-curing time was linked to an increase in KIC in most conditions. No differences in microhardness were detected across any group. The long-term resin generally had a greater DC, and the DC was greater for the 30-min post-curing time than for the 5-min time for the provisional resin printed by the DLP printer. Longer post-curing times resulted in more complete curing of the resins. DSC and DMA analyses revealed that the 30 min post-curing time enhanced the thermal stability of both provisional and long-term resins, indicating more homogeneous polymer network formation with reduced residual monomers. The printer type had a minor effect on the performance of the restorative polymers. In conclusion, the resin material is key for 3D-printed dental restoratives, and longer curing times improved their mechanical and thermal properties.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of the Mechanical Behavior of Biomedical Materials
Journal of the Mechanical Behavior of Biomedical Materials 工程技术-材料科学:生物材料
CiteScore
7.20
自引率
7.70%
发文量
505
审稿时长
46 days
期刊介绍: The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials. The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信