离子色谱-固相萃取法测定氯酸盐的研究进展

IF 3 3区 农林科学 Q2 FOOD SCIENCE & TECHNOLOGY
Josália L. R. Menezes, Amanda F. Lopes, Iuri M. de Melo, Tatiana Sainara M. Fernandes, Maria Edite B. da Rocha, Ronaldo F. do Nascimento
{"title":"离子色谱-固相萃取法测定氯酸盐的研究进展","authors":"Josália L. R. Menezes,&nbsp;Amanda F. Lopes,&nbsp;Iuri M. de Melo,&nbsp;Tatiana Sainara M. Fernandes,&nbsp;Maria Edite B. da Rocha,&nbsp;Ronaldo F. do Nascimento","doi":"10.1007/s12161-025-02847-2","DOIUrl":null,"url":null,"abstract":"<div><p>Water disinfection processes are essential to ensure safety and quality for consumption, but are often associated with the formation of Disinfection Byproducts (DBPs), such as ClO<sub>3</sub><sup>−</sup>, which are harmful and can impact the quality of water used in food processing. The presence of DBPs in water at levels above those permitted by government agencies can cause diarrhea and even death. In this context, the development of sensitive methods to control ClO<sub>3</sub><sup>−</sup> levels in water, such as those used in food processing, is essential. The ion chromatography (IC) is a powerful tool for determining DBPs and is reported in standard methods by the United States Environmental Protection Agency (U.S. EPA) to quantify these compounds in water. Thus, a new method based on SPE-IC-DC was developed to control ClO<sub>3</sub><sup>−</sup> levels in water used in food processing. A factorial study was used to optimize the SPE conditions, the chromatographic conditions were adjusted, and the method was validated. The method showed good selectivity and absence of matrix effect. The detection limit by SPE-IC was approximately 200 times lower (0.2 μg/L) when compared to the direct method, while the quantification limit was approximately 166 times lower (0.6 μg/L). The method was able to quantify ClO<sub>3</sub><sup>−</sup> in the samples at concentrations of 1.6 to 5.0 μg/L with adequate precision and accuracy. The results of the analysis of water samples from industrial juice processes indicated acceptable amounts of ClO<sub>3</sub><sup>−</sup>. The determination of ClO<sub>3</sub><sup>−</sup> by SPE-IC was efficient, inexpensive, and showed higher sensitivity, which makes it promising for use in quality control in waters used in food industries.\n</p></div>","PeriodicalId":561,"journal":{"name":"Food Analytical Methods","volume":"18 9","pages":"2025 - 2039"},"PeriodicalIF":3.0000,"publicationDate":"2025-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advances in Chlorate Determination by Ion Chromatography (IC)-Solid Phase Extraction (SPE)\",\"authors\":\"Josália L. R. Menezes,&nbsp;Amanda F. Lopes,&nbsp;Iuri M. de Melo,&nbsp;Tatiana Sainara M. Fernandes,&nbsp;Maria Edite B. da Rocha,&nbsp;Ronaldo F. do Nascimento\",\"doi\":\"10.1007/s12161-025-02847-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Water disinfection processes are essential to ensure safety and quality for consumption, but are often associated with the formation of Disinfection Byproducts (DBPs), such as ClO<sub>3</sub><sup>−</sup>, which are harmful and can impact the quality of water used in food processing. The presence of DBPs in water at levels above those permitted by government agencies can cause diarrhea and even death. In this context, the development of sensitive methods to control ClO<sub>3</sub><sup>−</sup> levels in water, such as those used in food processing, is essential. The ion chromatography (IC) is a powerful tool for determining DBPs and is reported in standard methods by the United States Environmental Protection Agency (U.S. EPA) to quantify these compounds in water. Thus, a new method based on SPE-IC-DC was developed to control ClO<sub>3</sub><sup>−</sup> levels in water used in food processing. A factorial study was used to optimize the SPE conditions, the chromatographic conditions were adjusted, and the method was validated. The method showed good selectivity and absence of matrix effect. The detection limit by SPE-IC was approximately 200 times lower (0.2 μg/L) when compared to the direct method, while the quantification limit was approximately 166 times lower (0.6 μg/L). The method was able to quantify ClO<sub>3</sub><sup>−</sup> in the samples at concentrations of 1.6 to 5.0 μg/L with adequate precision and accuracy. The results of the analysis of water samples from industrial juice processes indicated acceptable amounts of ClO<sub>3</sub><sup>−</sup>. The determination of ClO<sub>3</sub><sup>−</sup> by SPE-IC was efficient, inexpensive, and showed higher sensitivity, which makes it promising for use in quality control in waters used in food industries.\\n</p></div>\",\"PeriodicalId\":561,\"journal\":{\"name\":\"Food Analytical Methods\",\"volume\":\"18 9\",\"pages\":\"2025 - 2039\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-07-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Food Analytical Methods\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s12161-025-02847-2\",\"RegionNum\":3,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"FOOD SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Analytical Methods","FirstCategoryId":"97","ListUrlMain":"https://link.springer.com/article/10.1007/s12161-025-02847-2","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

水消毒过程对于确保消费安全和质量至关重要,但通常与消毒副产物(dbp)的形成有关,如ClO3−,这是有害的,可能影响食品加工中使用的水的质量。水中dbp的含量超过政府机构允许的水平会导致腹泻甚至死亡。在这种情况下,开发敏感的方法来控制水中的ClO3−水平,如在食品加工中使用的方法,是必不可少的。离子色谱法(IC)是测定DBPs的有力工具,美国环境保护署(U.S. EPA)报道了测定水中DBPs的标准方法。因此,开发了一种基于SPE-IC-DC的新方法来控制食品加工用水中的ClO3−水平。采用析因法优化固相萃取条件,调整色谱条件,并对方法进行验证。该方法选择性好,不存在基体效应。与直接法相比,SPE-IC法的检出限降低了约200倍(0.2 μg/L),定量限降低了约166倍(0.6 μg/L)。该方法能够定量样品中浓度为1.6 ~ 5.0 μg/L的ClO3−,具有足够的精密度和准确度。对工业果汁加工水样的分析结果表明ClO3−的含量是可以接受的。SPE-IC法测定ClO3−效率高、成本低、灵敏度高,在食品工业用水的质量控制中具有广阔的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Advances in Chlorate Determination by Ion Chromatography (IC)-Solid Phase Extraction (SPE)

Advances in Chlorate Determination by Ion Chromatography (IC)-Solid Phase Extraction (SPE)

Advances in Chlorate Determination by Ion Chromatography (IC)-Solid Phase Extraction (SPE)

Water disinfection processes are essential to ensure safety and quality for consumption, but are often associated with the formation of Disinfection Byproducts (DBPs), such as ClO3, which are harmful and can impact the quality of water used in food processing. The presence of DBPs in water at levels above those permitted by government agencies can cause diarrhea and even death. In this context, the development of sensitive methods to control ClO3 levels in water, such as those used in food processing, is essential. The ion chromatography (IC) is a powerful tool for determining DBPs and is reported in standard methods by the United States Environmental Protection Agency (U.S. EPA) to quantify these compounds in water. Thus, a new method based on SPE-IC-DC was developed to control ClO3 levels in water used in food processing. A factorial study was used to optimize the SPE conditions, the chromatographic conditions were adjusted, and the method was validated. The method showed good selectivity and absence of matrix effect. The detection limit by SPE-IC was approximately 200 times lower (0.2 μg/L) when compared to the direct method, while the quantification limit was approximately 166 times lower (0.6 μg/L). The method was able to quantify ClO3 in the samples at concentrations of 1.6 to 5.0 μg/L with adequate precision and accuracy. The results of the analysis of water samples from industrial juice processes indicated acceptable amounts of ClO3. The determination of ClO3 by SPE-IC was efficient, inexpensive, and showed higher sensitivity, which makes it promising for use in quality control in waters used in food industries.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Food Analytical Methods
Food Analytical Methods 农林科学-食品科技
CiteScore
6.00
自引率
3.40%
发文量
244
审稿时长
3.1 months
期刊介绍: Food Analytical Methods publishes original articles, review articles, and notes on novel and/or state-of-the-art analytical methods or issues to be solved, as well as significant improvements or interesting applications to existing methods. These include analytical technology and methodology for food microbial contaminants, food chemistry and toxicology, food quality, food authenticity and food traceability. The journal covers fundamental and specific aspects of the development, optimization, and practical implementation in routine laboratories, and validation of food analytical methods for the monitoring of food safety and quality.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信