工作场所空气中三氯苯胺的溶剂洗脱液相色谱测定方法。

Q3 Medicine
B B Chen, S Y Zheng, S R Yang, X L Fang, R F Li
{"title":"工作场所空气中三氯苯胺的溶剂洗脱液相色谱测定方法。","authors":"B B Chen, S Y Zheng, S R Yang, X L Fang, R F Li","doi":"10.3760/cma.j.cn121094-20240313-00095","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To establish a solvent elution-liquid chromatography method for the determination of trichloroaniline concentration in the air of the workplace. <b>Methods:</b> From December 2023 to January 2024, 2, 4, 5-trichloroaniline, 2, 4, 6-trichloroaniline, and 3, 4, 5-trichloroaniline in the air were collected using glass fiber filter membranes. After elution with acetonitrile and filtration with a 0.22 μm mixed cellulose filter membrane, isometric elution with acetonitrile and water (volume ratio 55∶45) was performed using a C8 column (250 mm×4.6 mm×5 μm) , and detection was carried out using a photo-diode array (PDA) detector. The detection limit, precision and other indicators of the method were analyzed. <b>Results:</b> The separation and determination of trichloroaniline isomers were completed within 9 minutes by the solvent elution-liquid chromatography method. The linear range was 0.1-30 μg/ml, the detection limit of the method was 0.005 μg/ml, the recoveries were 88%-98%, and the relative standard deviation was 0.3%-3.2%. <b>Conclusion:</b> The solvent elution-liquid chromatography method for the determination of trichloroaniline is simple and efficient. Both the recovery and precision meet the standard requirements for the determination of toxic substances in the workplace, and it is suitable for the detection of trichloroaniline in the workplace.</p>","PeriodicalId":23958,"journal":{"name":"中华劳动卫生职业病杂志","volume":"43 7","pages":"539-542"},"PeriodicalIF":0.0000,"publicationDate":"2025-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[The method of determination for trichloroaniline in the air of workplace by liquid chromatography with solvent elution].\",\"authors\":\"B B Chen, S Y Zheng, S R Yang, X L Fang, R F Li\",\"doi\":\"10.3760/cma.j.cn121094-20240313-00095\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> To establish a solvent elution-liquid chromatography method for the determination of trichloroaniline concentration in the air of the workplace. <b>Methods:</b> From December 2023 to January 2024, 2, 4, 5-trichloroaniline, 2, 4, 6-trichloroaniline, and 3, 4, 5-trichloroaniline in the air were collected using glass fiber filter membranes. After elution with acetonitrile and filtration with a 0.22 μm mixed cellulose filter membrane, isometric elution with acetonitrile and water (volume ratio 55∶45) was performed using a C8 column (250 mm×4.6 mm×5 μm) , and detection was carried out using a photo-diode array (PDA) detector. The detection limit, precision and other indicators of the method were analyzed. <b>Results:</b> The separation and determination of trichloroaniline isomers were completed within 9 minutes by the solvent elution-liquid chromatography method. The linear range was 0.1-30 μg/ml, the detection limit of the method was 0.005 μg/ml, the recoveries were 88%-98%, and the relative standard deviation was 0.3%-3.2%. <b>Conclusion:</b> The solvent elution-liquid chromatography method for the determination of trichloroaniline is simple and efficient. Both the recovery and precision meet the standard requirements for the determination of toxic substances in the workplace, and it is suitable for the detection of trichloroaniline in the workplace.</p>\",\"PeriodicalId\":23958,\"journal\":{\"name\":\"中华劳动卫生职业病杂志\",\"volume\":\"43 7\",\"pages\":\"539-542\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-07-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华劳动卫生职业病杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/cma.j.cn121094-20240313-00095\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华劳动卫生职业病杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121094-20240313-00095","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:建立溶剂洗脱-液相色谱法测定工作场所空气中三氯苯胺浓度的方法。方法:2023年12月至2024年1月,采用玻璃纤维过滤膜收集空气中的2,4,5 -三氯苯胺、2,4,6 -三氯苯胺和3,4,5 -三氯苯胺。乙腈洗脱,0.22 μm混合纤维素过滤膜过滤后,用C8柱(250 mm×4.6 mm×5 μm)等长洗脱(体积比55∶45),光电二极管阵列(PDA)检测器检测。分析了该方法的检出限、精密度等指标。结果:采用溶剂洗脱-液相色谱法,在9分钟内完成三氯苯胺异构体的分离和测定。线性范围为0.1 ~ 30 μg/ml,方法检出限为0.005 μg/ml,加样回收率为88% ~ 98%,相对标准偏差为0.3% ~ 3.2%。结论:溶剂洗脱-液相色谱法测定三氯苯胺简便、高效。回收率和精密度均符合工作场所有毒物质测定的标准要求,适用于工作场所中三氯苯胺的检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[The method of determination for trichloroaniline in the air of workplace by liquid chromatography with solvent elution].

Objective: To establish a solvent elution-liquid chromatography method for the determination of trichloroaniline concentration in the air of the workplace. Methods: From December 2023 to January 2024, 2, 4, 5-trichloroaniline, 2, 4, 6-trichloroaniline, and 3, 4, 5-trichloroaniline in the air were collected using glass fiber filter membranes. After elution with acetonitrile and filtration with a 0.22 μm mixed cellulose filter membrane, isometric elution with acetonitrile and water (volume ratio 55∶45) was performed using a C8 column (250 mm×4.6 mm×5 μm) , and detection was carried out using a photo-diode array (PDA) detector. The detection limit, precision and other indicators of the method were analyzed. Results: The separation and determination of trichloroaniline isomers were completed within 9 minutes by the solvent elution-liquid chromatography method. The linear range was 0.1-30 μg/ml, the detection limit of the method was 0.005 μg/ml, the recoveries were 88%-98%, and the relative standard deviation was 0.3%-3.2%. Conclusion: The solvent elution-liquid chromatography method for the determination of trichloroaniline is simple and efficient. Both the recovery and precision meet the standard requirements for the determination of toxic substances in the workplace, and it is suitable for the detection of trichloroaniline in the workplace.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中华劳动卫生职业病杂志
中华劳动卫生职业病杂志 Medicine-Medicine (all)
CiteScore
1.00
自引率
0.00%
发文量
9764
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信