不同角膜塑形镜设计引起的角膜高阶像差和相对屈光功率分布的比较。

IF 2.1 4区 医学 Q2 OPHTHALMOLOGY
Riping Zhang, Youming Zhou, Yunxuan Ou, Man Pan Chin, Jinyu Li, Vishal Jhanji, Mingzhi Zhang
{"title":"不同角膜塑形镜设计引起的角膜高阶像差和相对屈光功率分布的比较。","authors":"Riping Zhang, Youming Zhou, Yunxuan Ou, Man Pan Chin, Jinyu Li, Vishal Jhanji, Mingzhi Zhang","doi":"10.1097/ICL.0000000000001214","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study compared the myopia control effects of corneal high-order aberrations (CHOA) from two orthokeratology (OK) lenses based on their relative corneal refractive power shifts.</p><p><strong>Methods: </strong>In this prospective cohort study, 101 school children with low to moderate myopia were divided into three groups: group A (N=35) used 3-curve design lenses, group B (N=31) used 4-curve design lenses, and group C (N=35) wore regular spectacles. Cycloplegic refraction, visual acuity, and axial length (AL) were measured at baseline and after one year. Keratometry and CHOA were assessed before and after 3 months of lens wear. Relative corneal refractive power shifts and summed corneal power change (SCPC) were calculated. One-way ANOVA and planned comparison analyzed group differences.</p><p><strong>Results: </strong>Group B showed significantly slower AL elongation than group A (P=0.017) after OK treatment. Group B's SCPC was significantly higher than group A's (P≤0.005). Group B had a significant increase in horizontal coma (P=0.004). Increased SCPC led to more coma aberration with four-curve lens wear (P<0.01).</p><p><strong>Conclusions: </strong>The four-curve lens design was more effective in slowing AL elongation for OK treatment. It also caused significantly higher horizontal coma aberration than the three-curve design.</p>","PeriodicalId":50457,"journal":{"name":"Eye & Contact Lens-Science and Clinical Practice","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of the Corneal High-Order Aberration and Relative Corneal Refractive Power Distribution Induced by Different Orthokeratology Lenses Designs.\",\"authors\":\"Riping Zhang, Youming Zhou, Yunxuan Ou, Man Pan Chin, Jinyu Li, Vishal Jhanji, Mingzhi Zhang\",\"doi\":\"10.1097/ICL.0000000000001214\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study compared the myopia control effects of corneal high-order aberrations (CHOA) from two orthokeratology (OK) lenses based on their relative corneal refractive power shifts.</p><p><strong>Methods: </strong>In this prospective cohort study, 101 school children with low to moderate myopia were divided into three groups: group A (N=35) used 3-curve design lenses, group B (N=31) used 4-curve design lenses, and group C (N=35) wore regular spectacles. Cycloplegic refraction, visual acuity, and axial length (AL) were measured at baseline and after one year. Keratometry and CHOA were assessed before and after 3 months of lens wear. Relative corneal refractive power shifts and summed corneal power change (SCPC) were calculated. One-way ANOVA and planned comparison analyzed group differences.</p><p><strong>Results: </strong>Group B showed significantly slower AL elongation than group A (P=0.017) after OK treatment. Group B's SCPC was significantly higher than group A's (P≤0.005). Group B had a significant increase in horizontal coma (P=0.004). Increased SCPC led to more coma aberration with four-curve lens wear (P<0.01).</p><p><strong>Conclusions: </strong>The four-curve lens design was more effective in slowing AL elongation for OK treatment. It also caused significantly higher horizontal coma aberration than the three-curve design.</p>\",\"PeriodicalId\":50457,\"journal\":{\"name\":\"Eye & Contact Lens-Science and Clinical Practice\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye & Contact Lens-Science and Clinical Practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ICL.0000000000001214\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens-Science and Clinical Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000001214","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较两种角膜塑形(OK)镜片的角膜高阶像差(CHOA)对近视的控制效果。方法:采用前瞻性队列研究方法,将101名低中度近视学龄儿童分为3组:A组(35名)使用3曲线设计镜片,B组(31名)使用4曲线设计镜片,C组(35名)使用普通眼镜。在基线和一年后测量睫状体麻痹的屈光、视力和轴长(AL)。在佩戴晶状体3个月前后分别评估角膜测光和CHOA。计算角膜相对屈光度变化和角膜总屈光度变化(SCPC)。单因素方差分析和计划比较分析组间差异。结果:经OK处理后,B组AL伸长率明显低于A组(P=0.017)。B组SCPC显著高于A组(P≤0.005)。B组水平昏迷显著增加(P=0.004)。增加的SCPC导致更多的彗差和四曲线晶状体磨损(结论:四曲线晶状体设计更有效地减缓了OK治疗中AL的延伸。与三曲线设计相比,其水平彗差也显著提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of the Corneal High-Order Aberration and Relative Corneal Refractive Power Distribution Induced by Different Orthokeratology Lenses Designs.

Purpose: This study compared the myopia control effects of corneal high-order aberrations (CHOA) from two orthokeratology (OK) lenses based on their relative corneal refractive power shifts.

Methods: In this prospective cohort study, 101 school children with low to moderate myopia were divided into three groups: group A (N=35) used 3-curve design lenses, group B (N=31) used 4-curve design lenses, and group C (N=35) wore regular spectacles. Cycloplegic refraction, visual acuity, and axial length (AL) were measured at baseline and after one year. Keratometry and CHOA were assessed before and after 3 months of lens wear. Relative corneal refractive power shifts and summed corneal power change (SCPC) were calculated. One-way ANOVA and planned comparison analyzed group differences.

Results: Group B showed significantly slower AL elongation than group A (P=0.017) after OK treatment. Group B's SCPC was significantly higher than group A's (P≤0.005). Group B had a significant increase in horizontal coma (P=0.004). Increased SCPC led to more coma aberration with four-curve lens wear (P<0.01).

Conclusions: The four-curve lens design was more effective in slowing AL elongation for OK treatment. It also caused significantly higher horizontal coma aberration than the three-curve design.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
4.30%
发文量
150
审稿时长
6-12 weeks
期刊介绍: Eye & Contact Lens: Science and Clinical Practice is the official journal of the Contact Lens Association of Ophthalmologists (CLAO), an international educational association for anterior segment research and clinical practice of interest to ophthalmologists, optometrists, and other vision care providers and researchers. Focusing especially on contact lenses, it also covers dry eye disease, MGD, infections, toxicity of drops and contact lens care solutions, topography, cornea surgery and post-operative care, optics, refractive surgery and corneal stability (eg, UV cross-linking). Peer-reviewed and published six times annually, it is a highly respected scientific journal in its field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信