手持式超声设备在腹部病理评估中的应用及与高端超声设备的比较。

IF 2.9 Q2 Medicine
Ana Segura-Grau, Ines Salcedo-Joven, Esther Montes-Belloso, Sergio Cinza-Sanjurjo, Antonio Segura-Fragoso, Elena Segura-Grau
{"title":"手持式超声设备在腹部病理评估中的应用及与高端超声设备的比较。","authors":"Ana Segura-Grau, Ines Salcedo-Joven, Esther Montes-Belloso, Sergio Cinza-Sanjurjo, Antonio Segura-Fragoso, Elena Segura-Grau","doi":"10.1186/s13089-025-00433-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>The EFSUMB recommends the use of handheld ultrasound devices in many point-of-care cases, including primary care. However, it is necessary to continue training in conventional ultrasound examinations. Our aim is to analyze the diagnostic accuracy of handheld ultrasound devices in abdominal pathology compared with conventional high-end ultrasound scanners.</p><p><strong>Methodology: </strong>Agreement study between two ultrasound techniques, (1) POCUS (point-of-care ultrasound), with a General Electric<sup>®</sup> Vscan Air device and (2) standard ultrasound with a high-end Samsung RS 80<sup>®</sup> ultrasound scanner. Cohen's kappa was used for the analysis. The study was conducted between November 2022 and September 2023 in the general ultrasound unit of the San Francisco de Asís University Hospital in Madrid. It included all patients from the emergency department and the inpatient unit who have been referred for abdominal ultrasound.</p><p><strong>Results: </strong>A total of 93 patients were included (52.7% were women and the mean age was 65.6 (23.6) years). As regards body mass index (BMI), 11.8% had a BMI over 30 kg/m<sup>2</sup>. Of the scans performed, 69.9% were abdominal and the rest urological. Overall, the degree of agreement between the two tests was 89%, with 100% for liver and bladder pathology, 86.2% for renal pathology and 82.5% for complicated renal pathology. Intestinal (73.3%) and pancreatic (58.1%) pathologies showed the lowest correlation.</p><p><strong>Conclusions: </strong>The degree of agreement of handheld devices is high (89%), especially in renal and bladder pathologies, where ultrasound is decisive in decision-making. The agreement is weaker in pancreatic and gastrointestinal tract pathologies.</p>","PeriodicalId":36911,"journal":{"name":"Ultrasound Journal","volume":"17 1","pages":"38"},"PeriodicalIF":2.9000,"publicationDate":"2025-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12325146/pdf/","citationCount":"0","resultStr":"{\"title\":\"Usefulness of handheld ultrasound devices in the assessment of abdominal pathology and comparison with high-end ultrasound devices.\",\"authors\":\"Ana Segura-Grau, Ines Salcedo-Joven, Esther Montes-Belloso, Sergio Cinza-Sanjurjo, Antonio Segura-Fragoso, Elena Segura-Grau\",\"doi\":\"10.1186/s13089-025-00433-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objective: </strong>The EFSUMB recommends the use of handheld ultrasound devices in many point-of-care cases, including primary care. However, it is necessary to continue training in conventional ultrasound examinations. Our aim is to analyze the diagnostic accuracy of handheld ultrasound devices in abdominal pathology compared with conventional high-end ultrasound scanners.</p><p><strong>Methodology: </strong>Agreement study between two ultrasound techniques, (1) POCUS (point-of-care ultrasound), with a General Electric<sup>®</sup> Vscan Air device and (2) standard ultrasound with a high-end Samsung RS 80<sup>®</sup> ultrasound scanner. Cohen's kappa was used for the analysis. The study was conducted between November 2022 and September 2023 in the general ultrasound unit of the San Francisco de Asís University Hospital in Madrid. It included all patients from the emergency department and the inpatient unit who have been referred for abdominal ultrasound.</p><p><strong>Results: </strong>A total of 93 patients were included (52.7% were women and the mean age was 65.6 (23.6) years). As regards body mass index (BMI), 11.8% had a BMI over 30 kg/m<sup>2</sup>. Of the scans performed, 69.9% were abdominal and the rest urological. Overall, the degree of agreement between the two tests was 89%, with 100% for liver and bladder pathology, 86.2% for renal pathology and 82.5% for complicated renal pathology. Intestinal (73.3%) and pancreatic (58.1%) pathologies showed the lowest correlation.</p><p><strong>Conclusions: </strong>The degree of agreement of handheld devices is high (89%), especially in renal and bladder pathologies, where ultrasound is decisive in decision-making. The agreement is weaker in pancreatic and gastrointestinal tract pathologies.</p>\",\"PeriodicalId\":36911,\"journal\":{\"name\":\"Ultrasound Journal\",\"volume\":\"17 1\",\"pages\":\"38\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2025-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12325146/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasound Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s13089-025-00433-5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13089-025-00433-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:EFSUMB建议在包括初级保健在内的许多护理点病例中使用手持式超声设备。然而,继续进行常规超声检查的培训是必要的。我们的目的是分析手持式超声设备在腹部病理诊断的准确性与传统的高端超声扫描仪。方法:两种超声技术之间的一致性研究,(1)POCUS(点护理超声),使用通用电气®Vscan Air设备,(2)标准超声,使用高端三星RS 80®超声扫描仪。科恩kappa被用于分析。该研究于2022年11月至2023年9月在马德里旧金山Asís大学医院的普通超声部门进行。它包括所有从急诊科和住院部转介进行腹部超声检查的病人。结果:共纳入93例患者,其中女性占52.7%,平均年龄65.6(23.6)岁。在身体质量指数(BMI)方面,11.8%的人BMI超过30 kg/m2。在进行的扫描中,69.9%是腹部扫描,其余是泌尿系统扫描。总体而言,两种检查的符合度为89%,其中肝脏和膀胱病理符合度为100%,肾脏病理符合度为86.2%,复杂肾脏病理符合度为82.5%。肠道病理(73.3%)和胰腺病理(58.1%)相关性最低。结论:手持设备的诊断符合度很高(89%),特别是在肾脏和膀胱病变中,超声在这些疾病的诊断中具有决定性的作用。这种一致性在胰腺和胃肠道病变中较弱。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Usefulness of handheld ultrasound devices in the assessment of abdominal pathology and comparison with high-end ultrasound devices.

Usefulness of handheld ultrasound devices in the assessment of abdominal pathology and comparison with high-end ultrasound devices.

Usefulness of handheld ultrasound devices in the assessment of abdominal pathology and comparison with high-end ultrasound devices.

Usefulness of handheld ultrasound devices in the assessment of abdominal pathology and comparison with high-end ultrasound devices.

Usefulness of handheld ultrasound devices in the assessment of abdominal pathology and comparison with high-end ultrasound devices.

Background and objective: The EFSUMB recommends the use of handheld ultrasound devices in many point-of-care cases, including primary care. However, it is necessary to continue training in conventional ultrasound examinations. Our aim is to analyze the diagnostic accuracy of handheld ultrasound devices in abdominal pathology compared with conventional high-end ultrasound scanners.

Methodology: Agreement study between two ultrasound techniques, (1) POCUS (point-of-care ultrasound), with a General Electric® Vscan Air device and (2) standard ultrasound with a high-end Samsung RS 80® ultrasound scanner. Cohen's kappa was used for the analysis. The study was conducted between November 2022 and September 2023 in the general ultrasound unit of the San Francisco de Asís University Hospital in Madrid. It included all patients from the emergency department and the inpatient unit who have been referred for abdominal ultrasound.

Results: A total of 93 patients were included (52.7% were women and the mean age was 65.6 (23.6) years). As regards body mass index (BMI), 11.8% had a BMI over 30 kg/m2. Of the scans performed, 69.9% were abdominal and the rest urological. Overall, the degree of agreement between the two tests was 89%, with 100% for liver and bladder pathology, 86.2% for renal pathology and 82.5% for complicated renal pathology. Intestinal (73.3%) and pancreatic (58.1%) pathologies showed the lowest correlation.

Conclusions: The degree of agreement of handheld devices is high (89%), especially in renal and bladder pathologies, where ultrasound is decisive in decision-making. The agreement is weaker in pancreatic and gastrointestinal tract pathologies.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasound Journal
Ultrasound Journal Health Professions-Radiological and Ultrasound Technology
CiteScore
6.80
自引率
2.90%
发文量
45
审稿时长
22 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信