{"title":"“用于生物信号传感应用的带并联自引导电容的43.5dB增益单极A - igzo TFT放大器”的校误","authors":"Mingjian Zhao;Laiqing Li;Rui Liu;Bin Li;Rongsheng Chen;Zhaohui Wu","doi":"10.1109/TBCAS.2025.3583095","DOIUrl":null,"url":null,"abstract":"In [1], a critical labeling error was identified in Fig. 21, where the x-axis was incorrectly labeled “−50 ms to 50 ms” instead of the correct range “0 s to 5 s” (reflecting the actual ECG data duration). This discrepancy resulted from unintentional reuse of a plotting template and insufficient validation during proofing. While the underlying ECG waveform data remains accurate, the mislabeled scale misrepresents the signal’s temporal characteristics. The Fig. 21 should be corrected as follows:","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"19 4","pages":"850-850"},"PeriodicalIF":4.9000,"publicationDate":"2025-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11113505","citationCount":"0","resultStr":"{\"title\":\"Erratum to “A 43.5dB Gain Unipolar a-IGZO TFT Amplifier with Parallel Bootstrap Capacitor for Bio-signals Sensing Applications”\",\"authors\":\"Mingjian Zhao;Laiqing Li;Rui Liu;Bin Li;Rongsheng Chen;Zhaohui Wu\",\"doi\":\"10.1109/TBCAS.2025.3583095\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In [1], a critical labeling error was identified in Fig. 21, where the x-axis was incorrectly labeled “−50 ms to 50 ms” instead of the correct range “0 s to 5 s” (reflecting the actual ECG data duration). This discrepancy resulted from unintentional reuse of a plotting template and insufficient validation during proofing. While the underlying ECG waveform data remains accurate, the mislabeled scale misrepresents the signal’s temporal characteristics. The Fig. 21 should be corrected as follows:\",\"PeriodicalId\":94031,\"journal\":{\"name\":\"IEEE transactions on biomedical circuits and systems\",\"volume\":\"19 4\",\"pages\":\"850-850\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2025-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11113505\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on biomedical circuits and systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/11113505/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on biomedical circuits and systems","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11113505/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Erratum to “A 43.5dB Gain Unipolar a-IGZO TFT Amplifier with Parallel Bootstrap Capacitor for Bio-signals Sensing Applications”
In [1], a critical labeling error was identified in Fig. 21, where the x-axis was incorrectly labeled “−50 ms to 50 ms” instead of the correct range “0 s to 5 s” (reflecting the actual ECG data duration). This discrepancy resulted from unintentional reuse of a plotting template and insufficient validation during proofing. While the underlying ECG waveform data remains accurate, the mislabeled scale misrepresents the signal’s temporal characteristics. The Fig. 21 should be corrected as follows: