COVID-19大流行期间DS2防尘口罩带中巯基苯并噻唑致职业性变应性接触性皮炎:疫情研究及安全替代方案建议

IF 4.6 1区 医学 Q2 ALLERGY
Shigeruko Iijima, Tsuyoshi Kawakami, Masayo Kimura, Nobuko Sasaki, Fumiko Miyazawa, Yoko Mori, Maiko Tahara, Kayoko Matsunaga
{"title":"COVID-19大流行期间DS2防尘口罩带中巯基苯并噻唑致职业性变应性接触性皮炎:疫情研究及安全替代方案建议","authors":"Shigeruko Iijima, Tsuyoshi Kawakami, Masayo Kimura, Nobuko Sasaki, Fumiko Miyazawa, Yoko Mori, Maiko Tahara, Kayoko Matsunaga","doi":"10.1111/cod.70007","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The global COVID-19 pandemic has necessitated the widespread use of dust masks, including N95 and DS2, in healthcare settings. Although allergic contact dermatitis caused by dust mask straps has been reported, component analysis of the straps is rare. We encountered an outbreak of dermatitis cases due to rubber straps of a DS2 mask (Mask A) at our hospital.</p><p><strong>Objectives: </strong>To investigate the cause of dermatitis associated with Mask A rubber strap, identify the allergens responsible for allergic contact dermatitis and propose suitable alternative masks.</p><p><strong>Patients/methods: </strong>Twelve healthcare workers who developed contact dermatitis after wearing Mask A were enrolled. A detailed questionnaire, chemical analyses of Mask A rubber straps and alternatives and patch testing with identified components of the straps were performed.</p><p><strong>Results: </strong>Twelve cases (nine females, three males; mean age 47.8 ± 11.1 years) had no prior history of contact rubber allergy. The straps of Mask A contained thiazole-type vulcanisation accelerators and degradation products. Patch testing revealed sensitisation to 2-mercaptobenzothiazole, 2,2'-dithiobis(benzothiazole) and 2-(methylthio)benzothiazole in eight, three and five cases, respectively.</p><p><strong>Conclusion: </strong>Occupational allergic contact dermatitis due to 2-mercaptobenzothiazole in Mask A straps was diagnosed in eight cases. All affected individuals successfully switched to alternative masks without recurrence.</p>","PeriodicalId":10527,"journal":{"name":"Contact Dermatitis","volume":" ","pages":""},"PeriodicalIF":4.6000,"publicationDate":"2025-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Occupational Allergic Contact Dermatitis Caused by Mercaptobenzothiazole in DS2 Dust Mask Straps During the COVID-19 Pandemic: A Study of Outbreak and Proposal of Safer Alternatives.\",\"authors\":\"Shigeruko Iijima, Tsuyoshi Kawakami, Masayo Kimura, Nobuko Sasaki, Fumiko Miyazawa, Yoko Mori, Maiko Tahara, Kayoko Matsunaga\",\"doi\":\"10.1111/cod.70007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The global COVID-19 pandemic has necessitated the widespread use of dust masks, including N95 and DS2, in healthcare settings. Although allergic contact dermatitis caused by dust mask straps has been reported, component analysis of the straps is rare. We encountered an outbreak of dermatitis cases due to rubber straps of a DS2 mask (Mask A) at our hospital.</p><p><strong>Objectives: </strong>To investigate the cause of dermatitis associated with Mask A rubber strap, identify the allergens responsible for allergic contact dermatitis and propose suitable alternative masks.</p><p><strong>Patients/methods: </strong>Twelve healthcare workers who developed contact dermatitis after wearing Mask A were enrolled. A detailed questionnaire, chemical analyses of Mask A rubber straps and alternatives and patch testing with identified components of the straps were performed.</p><p><strong>Results: </strong>Twelve cases (nine females, three males; mean age 47.8 ± 11.1 years) had no prior history of contact rubber allergy. The straps of Mask A contained thiazole-type vulcanisation accelerators and degradation products. Patch testing revealed sensitisation to 2-mercaptobenzothiazole, 2,2'-dithiobis(benzothiazole) and 2-(methylthio)benzothiazole in eight, three and five cases, respectively.</p><p><strong>Conclusion: </strong>Occupational allergic contact dermatitis due to 2-mercaptobenzothiazole in Mask A straps was diagnosed in eight cases. All affected individuals successfully switched to alternative masks without recurrence.</p>\",\"PeriodicalId\":10527,\"journal\":{\"name\":\"Contact Dermatitis\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2025-08-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Contact Dermatitis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/cod.70007\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ALLERGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contact Dermatitis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/cod.70007","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ALLERGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:2019冠状病毒病全球大流行使得在卫生保健环境中广泛使用N95和DS2等防尘口罩成为必要。虽然已报道过由防尘口罩带引起的过敏性接触性皮炎,但对防尘口罩带的成分分析却很少。我们在我院遇到了因DS2口罩(口罩a)橡胶带引起的皮炎病例的爆发。目的:探讨与口罩A橡胶带相关的皮炎的原因,确定引起过敏性接触皮炎的过敏原,并提出合适的替代口罩。患者/方法:纳入12名佩戴A型口罩后发生接触性皮炎的医护人员。进行了详细的问卷调查、Mask A橡胶带及其替代品的化学分析,并对已识别的橡胶带成分进行了斑贴试验。结果:12例(女9例,男3例;平均年龄47.8±11.1岁)无接触性橡胶过敏史。掩膜A带含有噻唑型硫化促进剂和降解产物。斑贴试验显示,对2-巯基苯并噻唑、2,2'-二硫比斯(苯并噻唑)和2-(甲基硫)苯并噻唑分别致敏8例、3例和5例。结论:8例口罩A带中2-巯基苯并噻唑致职业性过敏性接触性皮炎。所有受影响的人都成功更换了其他口罩,没有复发。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Occupational Allergic Contact Dermatitis Caused by Mercaptobenzothiazole in DS2 Dust Mask Straps During the COVID-19 Pandemic: A Study of Outbreak and Proposal of Safer Alternatives.

Background: The global COVID-19 pandemic has necessitated the widespread use of dust masks, including N95 and DS2, in healthcare settings. Although allergic contact dermatitis caused by dust mask straps has been reported, component analysis of the straps is rare. We encountered an outbreak of dermatitis cases due to rubber straps of a DS2 mask (Mask A) at our hospital.

Objectives: To investigate the cause of dermatitis associated with Mask A rubber strap, identify the allergens responsible for allergic contact dermatitis and propose suitable alternative masks.

Patients/methods: Twelve healthcare workers who developed contact dermatitis after wearing Mask A were enrolled. A detailed questionnaire, chemical analyses of Mask A rubber straps and alternatives and patch testing with identified components of the straps were performed.

Results: Twelve cases (nine females, three males; mean age 47.8 ± 11.1 years) had no prior history of contact rubber allergy. The straps of Mask A contained thiazole-type vulcanisation accelerators and degradation products. Patch testing revealed sensitisation to 2-mercaptobenzothiazole, 2,2'-dithiobis(benzothiazole) and 2-(methylthio)benzothiazole in eight, three and five cases, respectively.

Conclusion: Occupational allergic contact dermatitis due to 2-mercaptobenzothiazole in Mask A straps was diagnosed in eight cases. All affected individuals successfully switched to alternative masks without recurrence.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Contact Dermatitis
Contact Dermatitis 医学-过敏
CiteScore
4.60
自引率
30.90%
发文量
227
审稿时长
4-8 weeks
期刊介绍: Contact Dermatitis is designed primarily as a journal for clinicians who are interested in various aspects of environmental dermatitis. This includes both allergic and irritant (toxic) types of contact dermatitis, occupational (industrial) dermatitis and consumers" dermatitis from such products as cosmetics and toiletries. The journal aims at promoting and maintaining communication among dermatologists, industrial physicians, allergists and clinical immunologists, as well as chemists and research workers involved in industry and the production of consumer goods. Papers are invited on clinical observations, diagnosis and methods of investigation of patients, therapeutic measures, organisation and legislation relating to the control of occupational and consumers".
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信