双层圆柱阵列引脚鳍微通道,散热能力高达1200w /cm2

IF 2.6 3区 工程技术 Q2 ENGINEERING, MECHANICAL
Ci Ao , Bo Xu , Zhenqian Chen
{"title":"双层圆柱阵列引脚鳍微通道,散热能力高达1200w /cm2","authors":"Ci Ao ,&nbsp;Bo Xu ,&nbsp;Zhenqian Chen","doi":"10.1016/j.ijheatfluidflow.2025.110003","DOIUrl":null,"url":null,"abstract":"<div><div>With the advancement of miniaturization and highly integrated microelectronic systems, the increasing heat flux in hotspot areas elevates the risk of thermal failure in chips. In light of this, a novel alternating cylindrical pin–fin array has been embedded in a double-layer cross-flow microchannel heat sink to enhance heat transfer. The research objectives of this study are to ensure that the hotspot temperature does not exceed the safe operating temperature of the chip under high heat flux conditions, while achieving optimal temperature uniformity and minimized pressure drop. To this end, the study first investigates the effects of different boundary conditions on the thermal performance of cross-flow microchannel heat sinks, and compares the heat transfer performance between cylindrical pin–fin microchannel heat sinks and conventional double-layer microchannel heat sinks. The results demonstrate that a cylindrical pin–fin array double-layer cross-flow microchannel heat sink using deionized water as coolant successfully removes a heat flux of 1200 W/cm<sup>2</sup> from a 2 × 2 mm<sup>2</sup> hotspot area. Notably, the arrangement of counter-flow in the upper and lower layers resolves the temperature gradient along the flow direction observed in unidirectional flow systems. Compared to co-flow microchannel heat sinks, the cross-flow configuration improves temperature uniformity by 1.15 %, and enhances the heat transfer coefficient to 35.56 kW/m<sup>2</sup>·K. Furthermore, a strong positive correlation exists between the heat transfer coefficient and Reynolds number. Variations in Re values induce a maximum pressure drop of 6.5 kPa while reducing the total thermal resistance to 0.44 K·cm<sup>2</sup>/W (conductive resistance: 0.238 K·cm<sup>2</sup>/W; convective resistance: 0.123 K·cm<sup>2</sup>/W).</div></div>","PeriodicalId":335,"journal":{"name":"International Journal of Heat and Fluid Flow","volume":"116 ","pages":"Article 110003"},"PeriodicalIF":2.6000,"publicationDate":"2025-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dual-layer cylindrical array of pin–fin microchannels with heat dissipation capacity up to 1200 W/cm2\",\"authors\":\"Ci Ao ,&nbsp;Bo Xu ,&nbsp;Zhenqian Chen\",\"doi\":\"10.1016/j.ijheatfluidflow.2025.110003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>With the advancement of miniaturization and highly integrated microelectronic systems, the increasing heat flux in hotspot areas elevates the risk of thermal failure in chips. In light of this, a novel alternating cylindrical pin–fin array has been embedded in a double-layer cross-flow microchannel heat sink to enhance heat transfer. The research objectives of this study are to ensure that the hotspot temperature does not exceed the safe operating temperature of the chip under high heat flux conditions, while achieving optimal temperature uniformity and minimized pressure drop. To this end, the study first investigates the effects of different boundary conditions on the thermal performance of cross-flow microchannel heat sinks, and compares the heat transfer performance between cylindrical pin–fin microchannel heat sinks and conventional double-layer microchannel heat sinks. The results demonstrate that a cylindrical pin–fin array double-layer cross-flow microchannel heat sink using deionized water as coolant successfully removes a heat flux of 1200 W/cm<sup>2</sup> from a 2 × 2 mm<sup>2</sup> hotspot area. Notably, the arrangement of counter-flow in the upper and lower layers resolves the temperature gradient along the flow direction observed in unidirectional flow systems. Compared to co-flow microchannel heat sinks, the cross-flow configuration improves temperature uniformity by 1.15 %, and enhances the heat transfer coefficient to 35.56 kW/m<sup>2</sup>·K. Furthermore, a strong positive correlation exists between the heat transfer coefficient and Reynolds number. Variations in Re values induce a maximum pressure drop of 6.5 kPa while reducing the total thermal resistance to 0.44 K·cm<sup>2</sup>/W (conductive resistance: 0.238 K·cm<sup>2</sup>/W; convective resistance: 0.123 K·cm<sup>2</sup>/W).</div></div>\",\"PeriodicalId\":335,\"journal\":{\"name\":\"International Journal of Heat and Fluid Flow\",\"volume\":\"116 \",\"pages\":\"Article 110003\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2025-08-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Heat and Fluid Flow\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0142727X25002619\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Heat and Fluid Flow","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0142727X25002619","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

随着微电子系统小型化和高集成化的发展,热点区域的热流密度增大,使得芯片热失效的风险增大。为此,在双层交叉流微通道散热器中嵌入了一种新型的交变圆柱形引脚鳍阵列,以增强传热能力。本研究的研究目标是保证热点温度在高热流密度条件下不超过芯片的安全工作温度,同时实现最佳的温度均匀性和最小的压降。为此,本研究首先考察了不同边界条件对横流微通道散热器热性能的影响,并比较了圆柱形针鳍微通道散热器与传统双层微通道散热器的换热性能。结果表明,以去离子水为冷却剂的圆柱形针鳍阵列双层交叉流微通道散热器成功地从2 × 2 mm2的热点区域去除了1200 W/cm2的热流通量。值得注意的是,上下两层逆流的排列解决了单向流动系统沿流动方向的温度梯度。与共流散热片相比,交叉流散热片的温度均匀性提高了1.15%,换热系数提高到35.56 kW/m2·K。此外,传热系数与雷诺数之间存在很强的正相关关系。Re值的变化导致最大压降为6.5 kPa,同时使总热阻降至0.44 K·cm2/W(导电电阻:0.238 K·cm2/W;对流阻力:0.123 K·cm2/W)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dual-layer cylindrical array of pin–fin microchannels with heat dissipation capacity up to 1200 W/cm2
With the advancement of miniaturization and highly integrated microelectronic systems, the increasing heat flux in hotspot areas elevates the risk of thermal failure in chips. In light of this, a novel alternating cylindrical pin–fin array has been embedded in a double-layer cross-flow microchannel heat sink to enhance heat transfer. The research objectives of this study are to ensure that the hotspot temperature does not exceed the safe operating temperature of the chip under high heat flux conditions, while achieving optimal temperature uniformity and minimized pressure drop. To this end, the study first investigates the effects of different boundary conditions on the thermal performance of cross-flow microchannel heat sinks, and compares the heat transfer performance between cylindrical pin–fin microchannel heat sinks and conventional double-layer microchannel heat sinks. The results demonstrate that a cylindrical pin–fin array double-layer cross-flow microchannel heat sink using deionized water as coolant successfully removes a heat flux of 1200 W/cm2 from a 2 × 2 mm2 hotspot area. Notably, the arrangement of counter-flow in the upper and lower layers resolves the temperature gradient along the flow direction observed in unidirectional flow systems. Compared to co-flow microchannel heat sinks, the cross-flow configuration improves temperature uniformity by 1.15 %, and enhances the heat transfer coefficient to 35.56 kW/m2·K. Furthermore, a strong positive correlation exists between the heat transfer coefficient and Reynolds number. Variations in Re values induce a maximum pressure drop of 6.5 kPa while reducing the total thermal resistance to 0.44 K·cm2/W (conductive resistance: 0.238 K·cm2/W; convective resistance: 0.123 K·cm2/W).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Heat and Fluid Flow
International Journal of Heat and Fluid Flow 工程技术-工程:机械
CiteScore
5.00
自引率
7.70%
发文量
131
审稿时长
33 days
期刊介绍: The International Journal of Heat and Fluid Flow welcomes high-quality original contributions on experimental, computational, and physical aspects of convective heat transfer and fluid dynamics relevant to engineering or the environment, including multiphase and microscale flows. Papers reporting the application of these disciplines to design and development, with emphasis on new technological fields, are also welcomed. Some of these new fields include microscale electronic and mechanical systems; medical and biological systems; and thermal and flow control in both the internal and external environment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信