胫骨平台水平截骨板设计对骨折块间压缩的影响:一项体外研究。

IF 1.1 2区 农林科学 Q3 VETERINARY SCIENCES
Diogo Miraldo, Rodrigo Alvarez, Maria Zurita
{"title":"胫骨平台水平截骨板设计对骨折块间压缩的影响:一项体外研究。","authors":"Diogo Miraldo, Rodrigo Alvarez, Maria Zurita","doi":"10.1055/a-2649-9074","DOIUrl":null,"url":null,"abstract":"<p><p>To compare immediate, static interfragmentary compression patterns of three tibial plateau leveling osteotomy (TPLO) plate designs.TPLO was performed on 15 synthetic canine tibiae (SYNBONE AG, Switzerland) using 3D-printed guides. Compression was evaluated using pressure-sensitive films (Prescale, Fujifilm, UK). Three 3.5-mm TPLO plates were tested according to the manufacturer guidelines for dynamic compression screws placement: Synthes, Arthrex, and Biocurve. Each plate was tested five times using a new bone model. The interfragmentary surface was divided into quadrants: Q1 (craniomedial), Q2 (craniolateral), Q3 (caudomedial), and Q4 (caudolateral). Compression was classified as low (<0.12 MPa), moderate (0.12-0.25 MPa), or high (>0.25 MPa).Significant differences in overall interfragmentary compression were found among the plates (<i>p</i> < 0.001). The Biocurve plate generated the highest and most uniform compression (Q1: 0.285 ± 0.023 MPa; Q2: 0.304 ± 0.010 MPa; Q3: 0.220 ± 0.014 MPa; Q4: 0.237 ± 0.010 MPa). The Arthrex plate produced high compression in Q2 (0.292 ± 0.012 MPa) and moderate in other quadrants (Q1: 0.177 ± 0.016 MPa; Q3: 0.141 ± 0.011 MPa; Q4: 0.189 ± 0.013 MPa). The Synthes plate showed the lowest compression throughout (Q1: 0.050 ± 0.008 MPa; Q2: 0.075 ± 0.009 MPa; Q3: 0.111 ± 0.008 MPa; Q4: 0.109 ± 0.008 MPa).The Biocurve plate, with two angled dynamic compression screw holes, provided the highest, most uniform compression. Further studies are needed to assess clinical relevance.</p>","PeriodicalId":51204,"journal":{"name":"Veterinary and Comparative Orthopaedics and Traumatology","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tibial Plateau Leveling Osteotomy Plate Design Influences Interfragmentary Compression: An In Vitro Study.\",\"authors\":\"Diogo Miraldo, Rodrigo Alvarez, Maria Zurita\",\"doi\":\"10.1055/a-2649-9074\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>To compare immediate, static interfragmentary compression patterns of three tibial plateau leveling osteotomy (TPLO) plate designs.TPLO was performed on 15 synthetic canine tibiae (SYNBONE AG, Switzerland) using 3D-printed guides. Compression was evaluated using pressure-sensitive films (Prescale, Fujifilm, UK). Three 3.5-mm TPLO plates were tested according to the manufacturer guidelines for dynamic compression screws placement: Synthes, Arthrex, and Biocurve. Each plate was tested five times using a new bone model. The interfragmentary surface was divided into quadrants: Q1 (craniomedial), Q2 (craniolateral), Q3 (caudomedial), and Q4 (caudolateral). Compression was classified as low (<0.12 MPa), moderate (0.12-0.25 MPa), or high (>0.25 MPa).Significant differences in overall interfragmentary compression were found among the plates (<i>p</i> < 0.001). The Biocurve plate generated the highest and most uniform compression (Q1: 0.285 ± 0.023 MPa; Q2: 0.304 ± 0.010 MPa; Q3: 0.220 ± 0.014 MPa; Q4: 0.237 ± 0.010 MPa). The Arthrex plate produced high compression in Q2 (0.292 ± 0.012 MPa) and moderate in other quadrants (Q1: 0.177 ± 0.016 MPa; Q3: 0.141 ± 0.011 MPa; Q4: 0.189 ± 0.013 MPa). The Synthes plate showed the lowest compression throughout (Q1: 0.050 ± 0.008 MPa; Q2: 0.075 ± 0.009 MPa; Q3: 0.111 ± 0.008 MPa; Q4: 0.109 ± 0.008 MPa).The Biocurve plate, with two angled dynamic compression screw holes, provided the highest, most uniform compression. Further studies are needed to assess clinical relevance.</p>\",\"PeriodicalId\":51204,\"journal\":{\"name\":\"Veterinary and Comparative Orthopaedics and Traumatology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2025-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary and Comparative Orthopaedics and Traumatology\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2649-9074\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary and Comparative Orthopaedics and Traumatology","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1055/a-2649-9074","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

比较三种胫骨平台平截骨(TPLO)钢板设计的即时、静态碎片间压缩模式。使用3d打印导向器对15条人工合成犬胫骨(瑞士SYNBONE AG)进行TPLO。使用压敏薄膜(Prescale, Fujifilm, UK)评估压缩情况。根据制造商动态加压螺钉放置指南:Synthes, Arthrex和bicurve,对三个3.5 mm TPLO钢板进行测试。每个板都用新的骨模型测试了五次。碎片间表面分为四个象限:Q1(颅内侧)、Q2(颅外侧)、Q3(尾内侧)和Q4(尾外侧)。压缩等级为低(0.25 MPa)。在整体碎片间压缩在不同的板之间发现显著差异(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Tibial Plateau Leveling Osteotomy Plate Design Influences Interfragmentary Compression: An In Vitro Study.

To compare immediate, static interfragmentary compression patterns of three tibial plateau leveling osteotomy (TPLO) plate designs.TPLO was performed on 15 synthetic canine tibiae (SYNBONE AG, Switzerland) using 3D-printed guides. Compression was evaluated using pressure-sensitive films (Prescale, Fujifilm, UK). Three 3.5-mm TPLO plates were tested according to the manufacturer guidelines for dynamic compression screws placement: Synthes, Arthrex, and Biocurve. Each plate was tested five times using a new bone model. The interfragmentary surface was divided into quadrants: Q1 (craniomedial), Q2 (craniolateral), Q3 (caudomedial), and Q4 (caudolateral). Compression was classified as low (<0.12 MPa), moderate (0.12-0.25 MPa), or high (>0.25 MPa).Significant differences in overall interfragmentary compression were found among the plates (p < 0.001). The Biocurve plate generated the highest and most uniform compression (Q1: 0.285 ± 0.023 MPa; Q2: 0.304 ± 0.010 MPa; Q3: 0.220 ± 0.014 MPa; Q4: 0.237 ± 0.010 MPa). The Arthrex plate produced high compression in Q2 (0.292 ± 0.012 MPa) and moderate in other quadrants (Q1: 0.177 ± 0.016 MPa; Q3: 0.141 ± 0.011 MPa; Q4: 0.189 ± 0.013 MPa). The Synthes plate showed the lowest compression throughout (Q1: 0.050 ± 0.008 MPa; Q2: 0.075 ± 0.009 MPa; Q3: 0.111 ± 0.008 MPa; Q4: 0.109 ± 0.008 MPa).The Biocurve plate, with two angled dynamic compression screw holes, provided the highest, most uniform compression. Further studies are needed to assess clinical relevance.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.00
自引率
15.40%
发文量
49
审稿时长
18-36 weeks
期刊介绍: Veterinary and Comparative Orthopaedics and Traumatology (VCOT) is the most important single source for clinically relevant information in orthopaedics and neurosurgery available anywhere in the world today. It is unique in that it is truly comparative and there is an unrivalled mix of review articles and basic science amid the information that is immediately clinically relevant in veterinary surgery today.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信