从睑板腺形态和功能预测隐形眼镜不适。

IF 3.7 3区 医学 Q1 OPHTHALMOLOGY
Fatima Iqbal, Eric B Papas, Fiona Stapleton, Waleed M Alghamdi, Amy Ruan, Karuna Darvesh, Lucy Nguyen, Jacqueline Tan
{"title":"从睑板腺形态和功能预测隐形眼镜不适。","authors":"Fatima Iqbal, Eric B Papas, Fiona Stapleton, Waleed M Alghamdi, Amy Ruan, Karuna Darvesh, Lucy Nguyen, Jacqueline Tan","doi":"10.1016/j.clae.2025.102480","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To develop and validate a model to predict contact lens discomfort (CLD) using features of the meibomian glands (MG).</p><p><strong>Methods: </strong>This study consisted of three parts: (i) 50 meibography images from contact lens wearers and non-wearers were assessed to distinguish features of interest between the groups to develop an automated algorithm which was tested on 154 images from CLD participants (ii) A multivariable model was constructed with a separate population of 84 lens wearers using imaging features and ocular surface signs to predict Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) score (iii) The model was validated on two independent sets of images using Bland-Altman comparisons between actual and predicted CLDEQ-8 scores.</p><p><strong>Results: </strong>Part I: Intergland distance and width of the gland at the lid margin, centre and distal end were identified as features distinguishing between lens wearers and non-wearers. Part II: In univariate analysis, CLDEQ-8 scores were negatively associated with gland width at the lid margin (r = -0.52, p = 0.01) and lipid layer thickness (r = -0.40, p < 0.05) and positively associated with tear break-up time (r = 0.51, p < 0.001), MG expressibility (r = 0.35, p = 0.01), and intergland distance at the lid margin (r = 0.73, p = 0.02). The multivariable regression model accounted for 68 % (R<sup>2</sup> = 0.68, p < 0.05) of the variance in CLDEQ-8 scores. Part III: The mean difference (bias) between the predicted and actual CLDEQ-8 score was -0.1 with limits of agreement of ± 2.8 units.</p><p><strong>Conclusion: </strong>Morphometric features of MG can predict CLDEQ-8 score in lens wearers with reasonable accuracy. This approach may be a suitable screening tool in early detection and to understand the natural history of CLD.</p>","PeriodicalId":49087,"journal":{"name":"Contact Lens & Anterior Eye","volume":" ","pages":"102480"},"PeriodicalIF":3.7000,"publicationDate":"2025-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Predicting contact lens discomfort from meibomian gland morphology and function.\",\"authors\":\"Fatima Iqbal, Eric B Papas, Fiona Stapleton, Waleed M Alghamdi, Amy Ruan, Karuna Darvesh, Lucy Nguyen, Jacqueline Tan\",\"doi\":\"10.1016/j.clae.2025.102480\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To develop and validate a model to predict contact lens discomfort (CLD) using features of the meibomian glands (MG).</p><p><strong>Methods: </strong>This study consisted of three parts: (i) 50 meibography images from contact lens wearers and non-wearers were assessed to distinguish features of interest between the groups to develop an automated algorithm which was tested on 154 images from CLD participants (ii) A multivariable model was constructed with a separate population of 84 lens wearers using imaging features and ocular surface signs to predict Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) score (iii) The model was validated on two independent sets of images using Bland-Altman comparisons between actual and predicted CLDEQ-8 scores.</p><p><strong>Results: </strong>Part I: Intergland distance and width of the gland at the lid margin, centre and distal end were identified as features distinguishing between lens wearers and non-wearers. Part II: In univariate analysis, CLDEQ-8 scores were negatively associated with gland width at the lid margin (r = -0.52, p = 0.01) and lipid layer thickness (r = -0.40, p < 0.05) and positively associated with tear break-up time (r = 0.51, p < 0.001), MG expressibility (r = 0.35, p = 0.01), and intergland distance at the lid margin (r = 0.73, p = 0.02). The multivariable regression model accounted for 68 % (R<sup>2</sup> = 0.68, p < 0.05) of the variance in CLDEQ-8 scores. Part III: The mean difference (bias) between the predicted and actual CLDEQ-8 score was -0.1 with limits of agreement of ± 2.8 units.</p><p><strong>Conclusion: </strong>Morphometric features of MG can predict CLDEQ-8 score in lens wearers with reasonable accuracy. This approach may be a suitable screening tool in early detection and to understand the natural history of CLD.</p>\",\"PeriodicalId\":49087,\"journal\":{\"name\":\"Contact Lens & Anterior Eye\",\"volume\":\" \",\"pages\":\"102480\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2025-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Contact Lens & Anterior Eye\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.clae.2025.102480\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contact Lens & Anterior Eye","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.clae.2025.102480","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:建立并验证一种利用睑板腺(MG)特征预测隐形眼镜不适(CLD)的模型。方法:本研究由三部分组成:(i)评估了来自隐形眼镜佩戴者和非佩戴者的50张meibography图像,以区分组间感兴趣的特征,并开发了一种自动算法,该算法对来自CLD参与者的154张图像进行了测试。(ii)构建了一个多变量模型,包括84名隐形眼镜佩戴者,使用成像特征和眼表体征来预测隐形眼镜干眼症问卷-8 (CLDEQ-8)得分Bland-Altman比较实际和预测的CLDEQ-8分数。结果:第一部分:眼睑边缘、中心和远端腺体间距离和宽度被确定为区分配戴者和非配戴者的特征。第二部分:在单变量分析中,CLDEQ-8评分与眼睑边缘腺体宽度(r = -0.52, p = 0.01)和脂质层厚度(r = -0.40, p 2 = 0.68, p)呈负相关。结论:MG形态计量学特征可以合理准确地预测晶状体佩戴者的CLDEQ-8评分。这种方法可能是早期发现和了解CLD自然历史的一种合适的筛选工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Predicting contact lens discomfort from meibomian gland morphology and function.

Purpose: To develop and validate a model to predict contact lens discomfort (CLD) using features of the meibomian glands (MG).

Methods: This study consisted of three parts: (i) 50 meibography images from contact lens wearers and non-wearers were assessed to distinguish features of interest between the groups to develop an automated algorithm which was tested on 154 images from CLD participants (ii) A multivariable model was constructed with a separate population of 84 lens wearers using imaging features and ocular surface signs to predict Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) score (iii) The model was validated on two independent sets of images using Bland-Altman comparisons between actual and predicted CLDEQ-8 scores.

Results: Part I: Intergland distance and width of the gland at the lid margin, centre and distal end were identified as features distinguishing between lens wearers and non-wearers. Part II: In univariate analysis, CLDEQ-8 scores were negatively associated with gland width at the lid margin (r = -0.52, p = 0.01) and lipid layer thickness (r = -0.40, p < 0.05) and positively associated with tear break-up time (r = 0.51, p < 0.001), MG expressibility (r = 0.35, p = 0.01), and intergland distance at the lid margin (r = 0.73, p = 0.02). The multivariable regression model accounted for 68 % (R2 = 0.68, p < 0.05) of the variance in CLDEQ-8 scores. Part III: The mean difference (bias) between the predicted and actual CLDEQ-8 score was -0.1 with limits of agreement of ± 2.8 units.

Conclusion: Morphometric features of MG can predict CLDEQ-8 score in lens wearers with reasonable accuracy. This approach may be a suitable screening tool in early detection and to understand the natural history of CLD.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.60
自引率
18.80%
发文量
198
审稿时长
55 days
期刊介绍: Contact Lens & Anterior Eye is a research-based journal covering all aspects of contact lens theory and practice, including original articles on invention and innovations, as well as the regular features of: Case Reports; Literary Reviews; Editorials; Instrumentation and Techniques and Dates of Professional Meetings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信