一种罕见的α -珠蛋白链变异的枫丹白露血红蛋白在两种不同的高效液相色谱系统中产生不同的结果,给诊断带来了挑战。

IF 0.6 4区 医学 Q4 HEMATOLOGY
Amar Dasgupta, Sachin Patil, Manoj Sawadkar, Akshay Dhotre, Manish Karekar, Shubhangi Mohanty, Aniruddha Belsare, Pallavi Thaker, Prabhakar S Kedar
{"title":"一种罕见的α -珠蛋白链变异的枫丹白露血红蛋白在两种不同的高效液相色谱系统中产生不同的结果,给诊断带来了挑战。","authors":"Amar Dasgupta, Sachin Patil, Manoj Sawadkar, Akshay Dhotre, Manish Karekar, Shubhangi Mohanty, Aniruddha Belsare, Pallavi Thaker, Prabhakar S Kedar","doi":"10.1007/s12308-025-00654-6","DOIUrl":null,"url":null,"abstract":"<p><p>Alpha globin chain variants constitute a very small fraction of the total hemoglobinopathy cases. Their rarity and the often-unfamiliar elution times/patterns in high performance liquid chromatography (HPLC) that mimic those of normal hemoglobin (Hb) fractions and/or known beta globin variants render their primary diagnosis difficult. We describe here Hb Fontainebleau, a rare alpha globin chain variant, in an adult female that eluted in the HbA2 window in a less commonly used HPLC platform, Lifotronic H8, thereby causing difficulties in the diagnosis. The matter was resolved by running the sample on a more commonly used platform wherein the abnormal Hb yielded a familiar elution time and pattern known to be associated with Hb Fontainebleau. This was further confirmed by gene sequencing, which showed a Codon 21 (G → C); HBA2:c.64G > C (or HBA1) mutation. A literature search failed to reveal any published case of the unique elution pattern of Hb Fontainebleau on Lifotronic H8 HPLC platform and the associated diagnostic challenges. An increasing use of the newer HPLC platforms calls for greater awareness of these issues.</p>","PeriodicalId":51320,"journal":{"name":"Journal of Hematopathology","volume":"18 1","pages":"36"},"PeriodicalIF":0.6000,"publicationDate":"2025-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A rare alpha globin chain variant hemoglobin Fontainebleau poses diagnostic challenges by yielding different results in two different HPLC systems.\",\"authors\":\"Amar Dasgupta, Sachin Patil, Manoj Sawadkar, Akshay Dhotre, Manish Karekar, Shubhangi Mohanty, Aniruddha Belsare, Pallavi Thaker, Prabhakar S Kedar\",\"doi\":\"10.1007/s12308-025-00654-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Alpha globin chain variants constitute a very small fraction of the total hemoglobinopathy cases. Their rarity and the often-unfamiliar elution times/patterns in high performance liquid chromatography (HPLC) that mimic those of normal hemoglobin (Hb) fractions and/or known beta globin variants render their primary diagnosis difficult. We describe here Hb Fontainebleau, a rare alpha globin chain variant, in an adult female that eluted in the HbA2 window in a less commonly used HPLC platform, Lifotronic H8, thereby causing difficulties in the diagnosis. The matter was resolved by running the sample on a more commonly used platform wherein the abnormal Hb yielded a familiar elution time and pattern known to be associated with Hb Fontainebleau. This was further confirmed by gene sequencing, which showed a Codon 21 (G → C); HBA2:c.64G > C (or HBA1) mutation. A literature search failed to reveal any published case of the unique elution pattern of Hb Fontainebleau on Lifotronic H8 HPLC platform and the associated diagnostic challenges. An increasing use of the newer HPLC platforms calls for greater awareness of these issues.</p>\",\"PeriodicalId\":51320,\"journal\":{\"name\":\"Journal of Hematopathology\",\"volume\":\"18 1\",\"pages\":\"36\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2025-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hematopathology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s12308-025-00654-6\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hematopathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12308-025-00654-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

α -珠蛋白链变异在所有血红蛋白病病例中只占很小的一部分。它们的罕见性和通常不熟悉的高效液相色谱(HPLC)的洗脱时间/模式,模仿正常血红蛋白(Hb)部分和/或已知的β -球蛋白变体,使其初步诊断困难。我们在这里描述了一种罕见的α珠蛋白链变异Hb Fontainebleau,在一名成年女性中,在一种不太常用的HPLC平台Lifotronic H8中,在HbA2窗口中洗脱,从而导致诊断困难。该问题通过在更常用的平台上运行样品来解决,其中异常Hb产生熟悉的洗脱时间和模式,已知与枫丹白露Hb相关。基因测序进一步证实了这一点,发现密码子21 (G→C);HBA2: c。64G > C(或HBA1)突变。文献检索未发现在Lifotronic H8高效液相色谱平台上发现枫丹白露血红蛋白独特洗脱模式的任何已发表病例及其相关的诊断挑战。越来越多地使用新的HPLC平台要求对这些问题有更多的认识。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A rare alpha globin chain variant hemoglobin Fontainebleau poses diagnostic challenges by yielding different results in two different HPLC systems.

Alpha globin chain variants constitute a very small fraction of the total hemoglobinopathy cases. Their rarity and the often-unfamiliar elution times/patterns in high performance liquid chromatography (HPLC) that mimic those of normal hemoglobin (Hb) fractions and/or known beta globin variants render their primary diagnosis difficult. We describe here Hb Fontainebleau, a rare alpha globin chain variant, in an adult female that eluted in the HbA2 window in a less commonly used HPLC platform, Lifotronic H8, thereby causing difficulties in the diagnosis. The matter was resolved by running the sample on a more commonly used platform wherein the abnormal Hb yielded a familiar elution time and pattern known to be associated with Hb Fontainebleau. This was further confirmed by gene sequencing, which showed a Codon 21 (G → C); HBA2:c.64G > C (or HBA1) mutation. A literature search failed to reveal any published case of the unique elution pattern of Hb Fontainebleau on Lifotronic H8 HPLC platform and the associated diagnostic challenges. An increasing use of the newer HPLC platforms calls for greater awareness of these issues.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Hematopathology
Journal of Hematopathology HEMATOLOGYPATHOLOGY-PATHOLOGY
CiteScore
0.80
自引率
0.00%
发文量
45
期刊介绍: The Journal of Hematopathology aims at providing pathologists with a special interest in hematopathology with all the information needed to perform modern pathology in evaluating lymphoid tissues and bone marrow. To this end the journal publishes reviews, editorials, comments, original papers, guidelines and protocols, papers on ancillary techniques, and occasional case reports in the fields of the pathology, molecular biology, and clinical features of diseases of the hematopoietic system. The journal is the unique reference point for all pathologists with an interest in hematopathology. Molecular biologists involved in the expanding field of molecular diagnostics and research on lymphomas and leukemia benefit from the journal, too. Furthermore, the journal is of major interest for hematologists dealing with patients suffering from lymphomas, leukemias, and other diseases. The journal is unique in its true international character. Especially in the field of hematopathology it is clear that there are huge geographical variations in incidence of diseases. This is not only locally relevant, but due to globalization, relevant for all those involved in the management of patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信