含有煅烧粘土和石灰石的水泥混合物制成的正常重量混凝土高温暴露后的残余性能

IF 3.3 3区 工程技术 Q2 ENGINEERING, CIVIL
Emad Yaghmour , Jaime Ibarra Campa , Mitzy Torres , Max Brown , Lauren Llantero , Spencer Quiel , Clay Naito
{"title":"含有煅烧粘土和石灰石的水泥混合物制成的正常重量混凝土高温暴露后的残余性能","authors":"Emad Yaghmour ,&nbsp;Jaime Ibarra Campa ,&nbsp;Mitzy Torres ,&nbsp;Max Brown ,&nbsp;Lauren Llantero ,&nbsp;Spencer Quiel ,&nbsp;Clay Naito","doi":"10.1016/j.firesaf.2025.104483","DOIUrl":null,"url":null,"abstract":"<div><div>Tests were conducted before and after high temperature exposure on normal weight concrete cylinders with mix designs that were identical except for their cementitious materials: 100 % ordinary Portland cement (OPC-100); 70 % OPC with 30 % metakaolin (i.e. calcined clay) (MK-30); 70 % OPC with 20 % metakaolin and 10 % limestone (LC2-30); and 70 % OPC with 18 % metakaolin, 9 % limestone, and 3 % gypsum (LC3-30). All concretes had comparable workability and compressive strengths at 1–28 days from casting. The inclusion of metakaolin reduced the ambient water permeability (up to 60 % less for MK-30), reflecting the observed change in microstructure from C-S-H gel in the OPC-100 to a denser C-A-S-H gel in mixes with metakaolin. Specimens were heated slowly (at a rate of 1–5 °C/min) to the first onset of spalling (at peak exposure temperatures of 307–350 °C) and then cooled to measure residual strength and water permeability. LC3-30 specimens exhibited the most spalling, and those that survived had the largest drop in residual strength (retaining ∼55 % of 28-day ambient strength, below current code-based values at these concrete temperatures). The other concretes suffered strength losses of 13–38 %, more consistent with code-based values. Residual permeability increased by an order of magnitude for all mixes after heating.</div></div>","PeriodicalId":50445,"journal":{"name":"Fire Safety Journal","volume":"157 ","pages":"Article 104483"},"PeriodicalIF":3.3000,"publicationDate":"2025-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Residual properties after high temperature exposure for normal weight concrete made with cement blends that include calcined clay and limestone\",\"authors\":\"Emad Yaghmour ,&nbsp;Jaime Ibarra Campa ,&nbsp;Mitzy Torres ,&nbsp;Max Brown ,&nbsp;Lauren Llantero ,&nbsp;Spencer Quiel ,&nbsp;Clay Naito\",\"doi\":\"10.1016/j.firesaf.2025.104483\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Tests were conducted before and after high temperature exposure on normal weight concrete cylinders with mix designs that were identical except for their cementitious materials: 100 % ordinary Portland cement (OPC-100); 70 % OPC with 30 % metakaolin (i.e. calcined clay) (MK-30); 70 % OPC with 20 % metakaolin and 10 % limestone (LC2-30); and 70 % OPC with 18 % metakaolin, 9 % limestone, and 3 % gypsum (LC3-30). All concretes had comparable workability and compressive strengths at 1–28 days from casting. The inclusion of metakaolin reduced the ambient water permeability (up to 60 % less for MK-30), reflecting the observed change in microstructure from C-S-H gel in the OPC-100 to a denser C-A-S-H gel in mixes with metakaolin. Specimens were heated slowly (at a rate of 1–5 °C/min) to the first onset of spalling (at peak exposure temperatures of 307–350 °C) and then cooled to measure residual strength and water permeability. LC3-30 specimens exhibited the most spalling, and those that survived had the largest drop in residual strength (retaining ∼55 % of 28-day ambient strength, below current code-based values at these concrete temperatures). The other concretes suffered strength losses of 13–38 %, more consistent with code-based values. Residual permeability increased by an order of magnitude for all mixes after heating.</div></div>\",\"PeriodicalId\":50445,\"journal\":{\"name\":\"Fire Safety Journal\",\"volume\":\"157 \",\"pages\":\"Article 104483\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2025-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Safety Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S037971122500147X\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Safety Journal","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S037971122500147X","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

摘要

在正常重量混凝土柱上进行高温暴露前后的试验,除胶凝材料不同外,配合比设计完全相同:100%普通波特兰水泥(OPC-100);70% OPC和30%偏高岭土(即煅烧粘土)(MK-30);70% OPC, 20%偏高岭土和10%石灰石(LC2-30);70% OPC, 18%偏高岭土,9%石灰石,3%石膏(LC3-30)。所有混凝土在浇筑后1-28天具有相当的和易性和抗压强度。偏高岭土的加入降低了环境水渗透率(MK-30的渗透率降低了60%),这反映了OPC-100中C-S-H凝胶的微观结构发生了变化,与偏高岭土混合后的C-A-S-H凝胶密度更高。将试样缓慢加热(速度为1-5℃/min)至第一次剥落(最高暴露温度为307-350℃),然后冷却以测量残余强度和透水性。LC3-30试件剥落最严重,幸存试件的残余强度下降最大(在这些混凝土温度下,保留28天环境强度的约55%,低于当前规范值)。其他混凝土的强度损失为13 - 38%,与规范值更为一致。加热后,所有混合物的残余渗透率都增加了一个数量级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Residual properties after high temperature exposure for normal weight concrete made with cement blends that include calcined clay and limestone
Tests were conducted before and after high temperature exposure on normal weight concrete cylinders with mix designs that were identical except for their cementitious materials: 100 % ordinary Portland cement (OPC-100); 70 % OPC with 30 % metakaolin (i.e. calcined clay) (MK-30); 70 % OPC with 20 % metakaolin and 10 % limestone (LC2-30); and 70 % OPC with 18 % metakaolin, 9 % limestone, and 3 % gypsum (LC3-30). All concretes had comparable workability and compressive strengths at 1–28 days from casting. The inclusion of metakaolin reduced the ambient water permeability (up to 60 % less for MK-30), reflecting the observed change in microstructure from C-S-H gel in the OPC-100 to a denser C-A-S-H gel in mixes with metakaolin. Specimens were heated slowly (at a rate of 1–5 °C/min) to the first onset of spalling (at peak exposure temperatures of 307–350 °C) and then cooled to measure residual strength and water permeability. LC3-30 specimens exhibited the most spalling, and those that survived had the largest drop in residual strength (retaining ∼55 % of 28-day ambient strength, below current code-based values at these concrete temperatures). The other concretes suffered strength losses of 13–38 %, more consistent with code-based values. Residual permeability increased by an order of magnitude for all mixes after heating.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Fire Safety Journal
Fire Safety Journal 工程技术-材料科学:综合
CiteScore
5.70
自引率
9.70%
发文量
153
审稿时长
60 days
期刊介绍: Fire Safety Journal is the leading publication dealing with all aspects of fire safety engineering. Its scope is purposefully wide, as it is deemed important to encourage papers from all sources within this multidisciplinary subject, thus providing a forum for its further development as a distinct engineering discipline. This is an essential step towards gaining a status equal to that enjoyed by the other engineering disciplines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信