Y X Wang, Y L Wang, S M Yu, Y Y Zhao, Y F Zhang, Q Yan
{"title":"[锥形束CT配准与口内扫描配准对机器人辅助手术种植体准确性的影响:一项使用模拟颅骨模型的研究]。","authors":"Y X Wang, Y L Wang, S M Yu, Y Y Zhao, Y F Zhang, Q Yan","doi":"10.3760/cma.j.cn112144-20241025-00401","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To compare the effects of using cone beam CT (CBCT) and oral scanning registration on implant positional accuracy during robot-assisted implant surgery, and to provide a basis for selecting the appropriate registration for robot-assisted implant surgical options. <b>Methods:</b> One patient with dentition defect, specifically missing teeth at positions 21 and 26 and having natural teeth adjacent mesially and distally to the edentulous area, who visited the Department of Oral Implantology, School of Hospital of Stomatology Wuhan University in 2024 were selected. Based on reconstructed imaging data, 30 identical jaw models were printed. These models were divided into a CBCT registration group and an intra-oral scanning registration group (15 models per group). An associate chief physician with extensive experience in implant surgery performed preoperative registration using the implant robot and completed the implant surgeries. Postoperative CBCT scans were used to determine the three-dimensional position of the implants. The deviations between the planned implant position and the actual position were evaluated, including deviations at the implantation point, apical point, and angular deviation. The differences between the two groups were compared. <b>Results:</b> The implantation deviation was 0.675 (0.490) mm, apical deviation was (0.680±0.272) mm, and the angular deviation was 0.566°±0.147° in the CBCT registration group, and in the intra-oral scanning registration group, implantation deviation was 0.695 (0.313) mm, apical deviation was (0.667±0.217) mm, and the angular deviation was 0.523°±0.168°. There was no statistically significant error in implant precision between the two groups (<i>P</i>>0.05). <b>Conclusions:</b> This <i>in vitro</i> experiment found that the use of intra-oral scanning registration in robot-assisted implant surgery can achieve similar implant placement accuracy as CBCT registration.</p>","PeriodicalId":23965,"journal":{"name":"中华口腔医学杂志","volume":"60 8","pages":"857-862"},"PeriodicalIF":0.0000,"publicationDate":"2025-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Effect of cone beam CT registration versus intraoral scanning registration on implant accuracy in robot-assisted surgery: a study using simulated skull models].\",\"authors\":\"Y X Wang, Y L Wang, S M Yu, Y Y Zhao, Y F Zhang, Q Yan\",\"doi\":\"10.3760/cma.j.cn112144-20241025-00401\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> To compare the effects of using cone beam CT (CBCT) and oral scanning registration on implant positional accuracy during robot-assisted implant surgery, and to provide a basis for selecting the appropriate registration for robot-assisted implant surgical options. <b>Methods:</b> One patient with dentition defect, specifically missing teeth at positions 21 and 26 and having natural teeth adjacent mesially and distally to the edentulous area, who visited the Department of Oral Implantology, School of Hospital of Stomatology Wuhan University in 2024 were selected. Based on reconstructed imaging data, 30 identical jaw models were printed. These models were divided into a CBCT registration group and an intra-oral scanning registration group (15 models per group). An associate chief physician with extensive experience in implant surgery performed preoperative registration using the implant robot and completed the implant surgeries. Postoperative CBCT scans were used to determine the three-dimensional position of the implants. The deviations between the planned implant position and the actual position were evaluated, including deviations at the implantation point, apical point, and angular deviation. The differences between the two groups were compared. <b>Results:</b> The implantation deviation was 0.675 (0.490) mm, apical deviation was (0.680±0.272) mm, and the angular deviation was 0.566°±0.147° in the CBCT registration group, and in the intra-oral scanning registration group, implantation deviation was 0.695 (0.313) mm, apical deviation was (0.667±0.217) mm, and the angular deviation was 0.523°±0.168°. There was no statistically significant error in implant precision between the two groups (<i>P</i>>0.05). <b>Conclusions:</b> This <i>in vitro</i> experiment found that the use of intra-oral scanning registration in robot-assisted implant surgery can achieve similar implant placement accuracy as CBCT registration.</p>\",\"PeriodicalId\":23965,\"journal\":{\"name\":\"中华口腔医学杂志\",\"volume\":\"60 8\",\"pages\":\"857-862\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华口腔医学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/cma.j.cn112144-20241025-00401\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华口腔医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn112144-20241025-00401","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
[Effect of cone beam CT registration versus intraoral scanning registration on implant accuracy in robot-assisted surgery: a study using simulated skull models].
Objective: To compare the effects of using cone beam CT (CBCT) and oral scanning registration on implant positional accuracy during robot-assisted implant surgery, and to provide a basis for selecting the appropriate registration for robot-assisted implant surgical options. Methods: One patient with dentition defect, specifically missing teeth at positions 21 and 26 and having natural teeth adjacent mesially and distally to the edentulous area, who visited the Department of Oral Implantology, School of Hospital of Stomatology Wuhan University in 2024 were selected. Based on reconstructed imaging data, 30 identical jaw models were printed. These models were divided into a CBCT registration group and an intra-oral scanning registration group (15 models per group). An associate chief physician with extensive experience in implant surgery performed preoperative registration using the implant robot and completed the implant surgeries. Postoperative CBCT scans were used to determine the three-dimensional position of the implants. The deviations between the planned implant position and the actual position were evaluated, including deviations at the implantation point, apical point, and angular deviation. The differences between the two groups were compared. Results: The implantation deviation was 0.675 (0.490) mm, apical deviation was (0.680±0.272) mm, and the angular deviation was 0.566°±0.147° in the CBCT registration group, and in the intra-oral scanning registration group, implantation deviation was 0.695 (0.313) mm, apical deviation was (0.667±0.217) mm, and the angular deviation was 0.523°±0.168°. There was no statistically significant error in implant precision between the two groups (P>0.05). Conclusions: This in vitro experiment found that the use of intra-oral scanning registration in robot-assisted implant surgery can achieve similar implant placement accuracy as CBCT registration.
期刊介绍:
Founded in August 1953, Chinese Journal of Stomatology is a monthly academic journal of stomatology published publicly at home and abroad, sponsored by the Chinese Medical Association and co-sponsored by the Chinese Stomatology Association. It mainly reports the leading scientific research results and clinical diagnosis and treatment experience in the field of oral medicine, as well as the basic theoretical research that has a guiding role in oral clinical practice and is closely combined with oral clinical practice.
Chinese Journal of Over the years, Stomatology has been published in Medline, Scopus database, Toxicology Abstracts Database, Chemical Abstracts Database, American Cancer database, Russian Abstracts database, China Core Journal of Science and Technology, Peking University Core Journal, CSCD and other more than 20 important journals at home and abroad Physical medicine database and retrieval system included.