{"title":"基于方形光路的Bell-Bloom磁强计。","authors":"Weipeng Li, Yue Chang, Xiaonan Zhang, Wenhao Luo, Xiaogang Wei, Renfu Yang","doi":"10.1364/OE.566844","DOIUrl":null,"url":null,"abstract":"<p><p>We present a single-beam Bell-Bloom magnetometer using a compact, square optical path in a vapor cell with intensity modulation of the light beam. This design achieves dead-zone-free three-axis magnetic field measurements and, additionally, can determine the magnitude and direction of the magnetic field gradient. Experimental results demonstrate the dead-zone-free operation, with sensitivity in each axis scaling with the effective optical path length along that direction. Strong magnetic field gradients induce distinct resonance peak splitting, whereby the splitting width is proportional to the gradient magnitude. By applying a reference gradient, the system can infer the direction of an external gradient, effectively functioning as a dual-axis gradiometer. Rotating the vapor cell allows optimization of the optical path to minimize gradient-induced measurement distortions by aligning it perpendicular to the gradient direction.</p>","PeriodicalId":19691,"journal":{"name":"Optics express","volume":"33 15","pages":"31635-31645"},"PeriodicalIF":3.3000,"publicationDate":"2025-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Bell-Bloom magnetometer based on square optical path.\",\"authors\":\"Weipeng Li, Yue Chang, Xiaonan Zhang, Wenhao Luo, Xiaogang Wei, Renfu Yang\",\"doi\":\"10.1364/OE.566844\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We present a single-beam Bell-Bloom magnetometer using a compact, square optical path in a vapor cell with intensity modulation of the light beam. This design achieves dead-zone-free three-axis magnetic field measurements and, additionally, can determine the magnitude and direction of the magnetic field gradient. Experimental results demonstrate the dead-zone-free operation, with sensitivity in each axis scaling with the effective optical path length along that direction. Strong magnetic field gradients induce distinct resonance peak splitting, whereby the splitting width is proportional to the gradient magnitude. By applying a reference gradient, the system can infer the direction of an external gradient, effectively functioning as a dual-axis gradiometer. Rotating the vapor cell allows optimization of the optical path to minimize gradient-induced measurement distortions by aligning it perpendicular to the gradient direction.</p>\",\"PeriodicalId\":19691,\"journal\":{\"name\":\"Optics express\",\"volume\":\"33 15\",\"pages\":\"31635-31645\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2025-07-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Optics express\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1364/OE.566844\",\"RegionNum\":2,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optics express","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1364/OE.566844","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPTICS","Score":null,"Total":0}
Bell-Bloom magnetometer based on square optical path.
We present a single-beam Bell-Bloom magnetometer using a compact, square optical path in a vapor cell with intensity modulation of the light beam. This design achieves dead-zone-free three-axis magnetic field measurements and, additionally, can determine the magnitude and direction of the magnetic field gradient. Experimental results demonstrate the dead-zone-free operation, with sensitivity in each axis scaling with the effective optical path length along that direction. Strong magnetic field gradients induce distinct resonance peak splitting, whereby the splitting width is proportional to the gradient magnitude. By applying a reference gradient, the system can infer the direction of an external gradient, effectively functioning as a dual-axis gradiometer. Rotating the vapor cell allows optimization of the optical path to minimize gradient-induced measurement distortions by aligning it perpendicular to the gradient direction.
期刊介绍:
Optics Express is the all-electronic, open access journal for optics providing rapid publication for peer-reviewed articles that emphasize scientific and technology innovations in all aspects of optics and photonics.