Anderson Fernando de Souza, César Augusto Martins Pereira, Ivan Onone Gialain, Josete Barbosa Cruz Meira, Rafael Yague Ballester, André Luis do Valle De Zoppa
{"title":"用锁定加压钢板对马近端指间关节融合术应力分布的计算机分析。","authors":"Anderson Fernando de Souza, César Augusto Martins Pereira, Ivan Onone Gialain, Josete Barbosa Cruz Meira, Rafael Yague Ballester, André Luis do Valle De Zoppa","doi":"10.1055/a-2655-0004","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to compare the stress distribution in proximal interphalangeal joint arthrodesis with locking compression plate in horses based on the type and method of screw implantation in the proximal hole and partial or total removal of implants after fusion.Finite element analysis.Proximal interphalangeal joint arthrodesis was simulated using a 3-hole, 4.5-mm narrow locking compression plate combined with two 5.5-mm transarticular screws. Models were created according to the type (cortex or locking) and method of implantation (uni- or bicortical) of the screw in the proximal hole of the locking compression plate. Four conditions were simulated: Immediate postoperative, ankylosis, ankylosis with partial removal (transarticular screws remaining) and ankylosis with no implants. An axial load of 8,700 N was applied, and the major principal stresses in the bones and von Mises stress in the implants were evaluated.Cortical screws in the proximal hole better distributed the stresses, reducing their concentration along the diaphysis of the proximal phalanx in the postoperative condition. Stress distribution did not differ between partial and total implant removal. High stresses were observed in the implants, especially when locking screws were used, with a reduction observed after ankylosis simulation.A cortex screw in the proximal hole reduces stress concentration in the proximal phalanx. Retaining the transarticular screws after ankylosis did not alter the stress pattern in the bone.</p>","PeriodicalId":51204,"journal":{"name":"Veterinary and Comparative Orthopaedics and Traumatology","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2025-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In Silico Analysis of Stress Distribution in Proximal Interphalangeal Joint Arthrodesis in Horses Using a Locking Compression Plate.\",\"authors\":\"Anderson Fernando de Souza, César Augusto Martins Pereira, Ivan Onone Gialain, Josete Barbosa Cruz Meira, Rafael Yague Ballester, André Luis do Valle De Zoppa\",\"doi\":\"10.1055/a-2655-0004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to compare the stress distribution in proximal interphalangeal joint arthrodesis with locking compression plate in horses based on the type and method of screw implantation in the proximal hole and partial or total removal of implants after fusion.Finite element analysis.Proximal interphalangeal joint arthrodesis was simulated using a 3-hole, 4.5-mm narrow locking compression plate combined with two 5.5-mm transarticular screws. Models were created according to the type (cortex or locking) and method of implantation (uni- or bicortical) of the screw in the proximal hole of the locking compression plate. Four conditions were simulated: Immediate postoperative, ankylosis, ankylosis with partial removal (transarticular screws remaining) and ankylosis with no implants. An axial load of 8,700 N was applied, and the major principal stresses in the bones and von Mises stress in the implants were evaluated.Cortical screws in the proximal hole better distributed the stresses, reducing their concentration along the diaphysis of the proximal phalanx in the postoperative condition. Stress distribution did not differ between partial and total implant removal. High stresses were observed in the implants, especially when locking screws were used, with a reduction observed after ankylosis simulation.A cortex screw in the proximal hole reduces stress concentration in the proximal phalanx. Retaining the transarticular screws after ankylosis did not alter the stress pattern in the bone.</p>\",\"PeriodicalId\":51204,\"journal\":{\"name\":\"Veterinary and Comparative Orthopaedics and Traumatology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2025-07-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary and Comparative Orthopaedics and Traumatology\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2655-0004\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary and Comparative Orthopaedics and Traumatology","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1055/a-2655-0004","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
In Silico Analysis of Stress Distribution in Proximal Interphalangeal Joint Arthrodesis in Horses Using a Locking Compression Plate.
This study aimed to compare the stress distribution in proximal interphalangeal joint arthrodesis with locking compression plate in horses based on the type and method of screw implantation in the proximal hole and partial or total removal of implants after fusion.Finite element analysis.Proximal interphalangeal joint arthrodesis was simulated using a 3-hole, 4.5-mm narrow locking compression plate combined with two 5.5-mm transarticular screws. Models were created according to the type (cortex or locking) and method of implantation (uni- or bicortical) of the screw in the proximal hole of the locking compression plate. Four conditions were simulated: Immediate postoperative, ankylosis, ankylosis with partial removal (transarticular screws remaining) and ankylosis with no implants. An axial load of 8,700 N was applied, and the major principal stresses in the bones and von Mises stress in the implants were evaluated.Cortical screws in the proximal hole better distributed the stresses, reducing their concentration along the diaphysis of the proximal phalanx in the postoperative condition. Stress distribution did not differ between partial and total implant removal. High stresses were observed in the implants, especially when locking screws were used, with a reduction observed after ankylosis simulation.A cortex screw in the proximal hole reduces stress concentration in the proximal phalanx. Retaining the transarticular screws after ankylosis did not alter the stress pattern in the bone.
期刊介绍:
Veterinary and Comparative Orthopaedics and Traumatology (VCOT) is the most important single source for clinically relevant information in orthopaedics and neurosurgery available anywhere in the world today. It is unique in that it is truly comparative and there is an unrivalled mix of review articles and basic science amid the information that is immediately clinically relevant in veterinary surgery today.