睫状沟植入术中8种人工晶体度数计算公式的准确性。

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY
Pusheng Xu, Xinyu Zhang, Zhangkai Lian, Zhenzhen Liu, Charlotte Aimee Young, Siyuan Liu, Danying Zheng, Guangming Jin
{"title":"睫状沟植入术中8种人工晶体度数计算公式的准确性。","authors":"Pusheng Xu, Xinyu Zhang, Zhangkai Lian, Zhenzhen Liu, Charlotte Aimee Young, Siyuan Liu, Danying Zheng, Guangming Jin","doi":"10.1007/s10792-025-03684-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the accuracy of intraocular lens (IOL) power calculation for ciliary sulcus-implanted IOL.</p><p><strong>Methods: </strong>Patients with IOL (Tecnis ZA9003) implanted in the ciliary sulcus were reviewed from March 1, 2021 to November 1, 2024 at Zhongshan Ophthalmic Center, Guangzhou, China. Optic capture was used at all case. The prediction error (PE) and mean absolute error (MAE) of eight new and old formulas including Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), Haigis, Hoffer QST, Holladay 1, Kane, Radial Basis Function 3.0 (RBF 3.0), and SRK/T formula were compared. The second-generation Wang-Koch adjustment (WK2) for axial length (AL) > 26.5 mm and adjusted surgeon factor for IOL implanted in the ciliary sulcus (SF_cs) were used to modify Holladay 1 formula.</p><p><strong>Results: </strong>56 eyes from 56 patients were enrolled. The performance of each formula ranked by mean PE from lowest to highest were Holladay 1 (- 0.42 D), BUII (- 0.47 D), EVO (- 0.49 D), Haigis (- 0.49 D), RBF 3.0 (- 0.52 D), SRK/T (- 0.53 D), Kane (- 0.56 D), and Hoffer QST (- 0.58 D). BUII formula reached the lowest MAE (0.68 D), while Hoffer QST and Kane formula had the highest MAE (0.75 D). Holladay 1, modified with WK2 and a SF_sc of 1.37, achieved a mean PE of 0 ± 0.67 D, the lowest MAE (0.52) and MedAE (0.40), as well as the highest percentage of eyes with PE within ± 0.25 D, ± 0.50 D, and ± 1.00 D.</p><p><strong>Conclusion: </strong>Among the eight included formulas, Holladay 1 formula modified with WK2 adjustment and a SF_cs of 1.37 was recommended for patients with sulcus-implanted optic-captured ZA9003 IOL.</p>","PeriodicalId":14473,"journal":{"name":"International Ophthalmology","volume":"45 1","pages":"316"},"PeriodicalIF":1.4000,"publicationDate":"2025-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of eight intraocular lens power calculation formulas in patients with ciliary sulcus implantation.\",\"authors\":\"Pusheng Xu, Xinyu Zhang, Zhangkai Lian, Zhenzhen Liu, Charlotte Aimee Young, Siyuan Liu, Danying Zheng, Guangming Jin\",\"doi\":\"10.1007/s10792-025-03684-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the accuracy of intraocular lens (IOL) power calculation for ciliary sulcus-implanted IOL.</p><p><strong>Methods: </strong>Patients with IOL (Tecnis ZA9003) implanted in the ciliary sulcus were reviewed from March 1, 2021 to November 1, 2024 at Zhongshan Ophthalmic Center, Guangzhou, China. Optic capture was used at all case. The prediction error (PE) and mean absolute error (MAE) of eight new and old formulas including Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), Haigis, Hoffer QST, Holladay 1, Kane, Radial Basis Function 3.0 (RBF 3.0), and SRK/T formula were compared. The second-generation Wang-Koch adjustment (WK2) for axial length (AL) > 26.5 mm and adjusted surgeon factor for IOL implanted in the ciliary sulcus (SF_cs) were used to modify Holladay 1 formula.</p><p><strong>Results: </strong>56 eyes from 56 patients were enrolled. The performance of each formula ranked by mean PE from lowest to highest were Holladay 1 (- 0.42 D), BUII (- 0.47 D), EVO (- 0.49 D), Haigis (- 0.49 D), RBF 3.0 (- 0.52 D), SRK/T (- 0.53 D), Kane (- 0.56 D), and Hoffer QST (- 0.58 D). BUII formula reached the lowest MAE (0.68 D), while Hoffer QST and Kane formula had the highest MAE (0.75 D). Holladay 1, modified with WK2 and a SF_sc of 1.37, achieved a mean PE of 0 ± 0.67 D, the lowest MAE (0.52) and MedAE (0.40), as well as the highest percentage of eyes with PE within ± 0.25 D, ± 0.50 D, and ± 1.00 D.</p><p><strong>Conclusion: </strong>Among the eight included formulas, Holladay 1 formula modified with WK2 adjustment and a SF_cs of 1.37 was recommended for patients with sulcus-implanted optic-captured ZA9003 IOL.</p>\",\"PeriodicalId\":14473,\"journal\":{\"name\":\"International Ophthalmology\",\"volume\":\"45 1\",\"pages\":\"316\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10792-025-03684-2\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10792-025-03684-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价睫状体沟植入术人工晶状体度数计算的准确性。方法:回顾性分析广州市中山眼科中心2021年3月1日至2024年11月1日睫状沟植入术人工晶体(Tecnis ZA9003)患者的临床资料。所有病例均采用光学捕获。比较Barrett Universal II (BUII)、Emmetropia Verifying Optical (EVO)、Haigis、Hoffer QST、Holladay 1、Kane、Radial Basis Function 3.0 (RBF 3.0)、SRK/T公式等8个新旧公式的预测误差(PE)和平均绝对误差(MAE)。采用第二代Wang-Koch轴长调整器(WK2) > 26.5 mm和睫状沟人工晶状体(SF_cs)调整手术因子对Holladay 1公式进行修改。结果:56例患者的56只眼睛被纳入研究。各配方的平均PE从低到高依次为Holladay 1 (- 0.42 D)、BUII (- 0.47 D)、EVO (- 0.49 D)、Haigis (- 0.49 D)、RBF 3.0 (- 0.52 D)、SRK/T (- 0.53 D)、Kane (- 0.56 D)和Hoffer QST (- 0.58 D)。BUII公式的MAE最低(0.68 D), Hoffer QST和Kane公式的MAE最高(0.75 D)。调整WK2和SF_sc为1.37的Holladay 1配方的平均PE为0±0.67 D,最低的MAE(0.52)和MedAE (0.40), PE在±0.25 D、±0.50 D和±1.00 D范围内的眼的比例最高。结论:在8个配方中,推荐调整WK2和SF_cs为1.37的Holladay 1配方适用于眼道植入的光捕获型ZA9003 IOL。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of eight intraocular lens power calculation formulas in patients with ciliary sulcus implantation.

Purpose: To evaluate the accuracy of intraocular lens (IOL) power calculation for ciliary sulcus-implanted IOL.

Methods: Patients with IOL (Tecnis ZA9003) implanted in the ciliary sulcus were reviewed from March 1, 2021 to November 1, 2024 at Zhongshan Ophthalmic Center, Guangzhou, China. Optic capture was used at all case. The prediction error (PE) and mean absolute error (MAE) of eight new and old formulas including Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), Haigis, Hoffer QST, Holladay 1, Kane, Radial Basis Function 3.0 (RBF 3.0), and SRK/T formula were compared. The second-generation Wang-Koch adjustment (WK2) for axial length (AL) > 26.5 mm and adjusted surgeon factor for IOL implanted in the ciliary sulcus (SF_cs) were used to modify Holladay 1 formula.

Results: 56 eyes from 56 patients were enrolled. The performance of each formula ranked by mean PE from lowest to highest were Holladay 1 (- 0.42 D), BUII (- 0.47 D), EVO (- 0.49 D), Haigis (- 0.49 D), RBF 3.0 (- 0.52 D), SRK/T (- 0.53 D), Kane (- 0.56 D), and Hoffer QST (- 0.58 D). BUII formula reached the lowest MAE (0.68 D), while Hoffer QST and Kane formula had the highest MAE (0.75 D). Holladay 1, modified with WK2 and a SF_sc of 1.37, achieved a mean PE of 0 ± 0.67 D, the lowest MAE (0.52) and MedAE (0.40), as well as the highest percentage of eyes with PE within ± 0.25 D, ± 0.50 D, and ± 1.00 D.

Conclusion: Among the eight included formulas, Holladay 1 formula modified with WK2 adjustment and a SF_cs of 1.37 was recommended for patients with sulcus-implanted optic-captured ZA9003 IOL.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
0.00%
发文量
451
期刊介绍: International Ophthalmology provides the clinician with articles on all the relevant subspecialties of ophthalmology, with a broad international scope. The emphasis is on presentation of the latest clinical research in the field. In addition, the journal includes regular sections devoted to new developments in technologies, products, and techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信